DCS Vent Hood ES30 Скачать руководство пользователя страница 19

WARRANTY

18

7. Noise or vibration that is considered normal, for example, drain/fan sounds, regeneration

noises or user warning beeps.

8. Correcting damage caused by pests, for example, rats, cockroaches etc.

B.  Defects caused by factors other than:

1.  Normal domestic use or

2.  Use in accordance with the Product’s Use and Care Guide.

C.  Defects to the Product caused by accident, neglect, misuse, fire, flood or Act of God.

D.  The cost of repairs carried out by non-authorized repairers or the cost of correcting such 

unauthorized repairs.

E.  Travel Fees and associated charges incurred when the product is installed in a location with limited

or restricted access. (i.e. airplane  flights, ferry charges, isolated geographic areas).

F.  Normal recommended maintenance as set forth in the Product’s Use and Care Guide.

If you have an installation problem contact your dealer or installer. You are responsible for providing
adequate electrical, exhausting and other connection facilities.  We are not responsible for
consequential or incidental damages (the cost of repairing or replacing other property damaged if the
Product is defective or any of your expenses caused if the Product is defective). Some states do not
allow the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.

HOW TO GET SERVICE

Please read your Use and Care Guide. If you then have any questions about operating the Product,
need the name of your local DCS Authorized Service Agent, or believe the Product is defective and
wish service under this Limited Warranty, please contact your dealer or call us at:

TOLL FREE 

1-888-936-7872

or contact us through our web site: www.dcsappliances.com.

You may be required to provide reasonable proof of the date of purchase of the Product before the
Product will be serviced under this Limited Warranty.

COMMERCIAL USE

This warranty applies to appliances used in residential applications; it does not cover their use in
commercial situations. 

NO OTHER WARRANTIES

This Limited  Warranty is the complete and exclusive agreement between you and Fisher & Paykel
Appliances, Inc. regarding any defect in the Product. None of our employees (or our Authorized
Service Agents) are authorised to make any addition or modification to this Limited Warranty.

Warrantor: Fisher & Paykel Appliances, Inc.

If you need further help concerning this Limited Warranty, please call us at the above number, or write
to:

Fisher & Paykel Appliances, Inc.
5900 Skylab Road, Huntington Beach, CA 92647

This Limited Warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.

Содержание Vent Hood ES30

Страница 1: ...THE PROFESSIONAL AND EURO VENT HOOD Installation Guide MODELS VS30 VS36 VS48 RDS 364GD VS1236 ES30 ES36 486GD...

Страница 2: ...on the inner back panel behind grease filters below motor assembly MODEL NUMBER CODE SERIAL NUMBER WARNING If the information in this manual is not followed exactly a fire or explosion may result cau...

Страница 3: ...persons in the event of a rangetop grease fire observe the following Turn burner off first Smother flames with a close fitting lid cookie sheet or metal tray Be careful to prevent burns If the flames...

Страница 4: ...ent air is needed to maintain proper combustion and safe exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturers guide...

Страница 5: ...etal tray then turn off the gas burner or the electric element BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN y...

Страница 6: ...pipe DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in electrical shock Check with a qualified electrician if you are in doubt as to whe...

Страница 7: ...12 Duct Cover Accessory Height ES30 14 15 16 ES36 17 15 16 12 6 25 2 18 6 or 12 Duct Cover Accessory Height VS30 29 7 8 VS36 VS1236 35 7 8 VS48 47 7 8 VS30 29 7 8 VS36 VS1236 35 7 8 VS48 47 7 8 VS30 1...

Страница 8: ...ral Blower PARTS NOT INCLUDED WITH YOUR HOOD Ducting See Page 9 for duct requirements 8 or 10 to be used Duct Tape 1 2 Conduit Wire Nuts Optional duct cover 6 or 12 height VDC1230 12 Duct cover kit fo...

Страница 9: ...cific requirements in your area 7 Hood installation height above cooktop is the users preference Lower installation heights will improve the efficiency of capturing cooking odors grease and smoke This...

Страница 10: ...36 are supplied with a starting collar and backdraft damper on top of the hood for connection to 8 round duct Models VS1236 and VS48 are supplied with a 10 round transition with damper and is assemble...

Страница 11: ...uct covers can be joined together in any combination 1 Hood Installation Height After the hood installation height has been determined draw a horizontal line at a distance above the cooktop equal to t...

Страница 12: ...tud 7 Use 2 to 4 1 4 x 3 flat head wood screws to attach the bracket to the wall as shown in Figure 4 For support of longer hoods use three or four studs as available Countersink the heads to prevent...

Страница 13: ...screws and seal with duct tape Screws must not hamper the damper 15 Drill a 3 8 hole through the center of the holes K into the wall Insert two wall plugs into drilled holes Tighten hood to wall anch...

Страница 14: ...H G I 1 1 2 Dia Holes Vertical conduit option A B C D E F G H I Min 12 6 10 6 3 4 1 7 8 5 3 4 5 7 8 1 7 8 5 1 8 ES30 30 ES36 36 C L Cabinet Vertical Discharge Cutout Width Bottom of Cabinet or Soffit...

Страница 15: ...pace of about 1 2 from cabinet bottom surface and screw heads 4 Hang the hood on screws through side slots provided on hood top Tighten the four screws Drill a 3 8 hole through the center of the holes...

Страница 16: ...e j box cover as shown in Figure 11 3 Remove 1 of 2 knockouts and install 1 2 conduit connector in j box 4 Run black white and green wires 18 AWG in 1 2 conduit from power supply to j box 5 Connect th...

Страница 17: ...nd grease filters below motor assembly Serial Number located on the inner back panel behind grease filters below motor assembly Code located on the inner back panel behind grease filters below motor a...

Страница 18: ...r of attempts at our option we may replace the part or the Product or we may provide you a full refund of the purchase price of the Product not including installation or other charges This warranty ex...

Страница 19: ...limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you HOW TO GET SERVICE Please read your Use and Care Guide If you then have any questions about...

Страница 20: ...dcsappliances com As product improvement is an ongoing process we reserve the right to change specifications or design without notice Nous am liorons constamment ses produits et se r serve le droit d...

Отзывы: