INTEGRAL VENTILATOR INSTALLATION

The Integral ventilator can be mounted to discharge air as shown in Figure 9.  From the inside of the
hood, slip motor into the bracket on the left. Rotate motor upwards until it snaps into the spring clip
on the right. 

IMPORTANT: 

Secure the motor to the hood with the machine screw and lock washer. 

WIRING THE HOOD:

WARNING:  

Turn off electricity at the service panel before wiring the unit.
Branch circuit requirement is 120V, 60Hz, 15A (minimum).

1.   Connect the Integral Ventilator molex plug

connector to the connector present inside the
hood as shown in Figure 9 or Figure 10.

2.   Remove the j-box cover as shown in Figure 11.

3.   Remove 1 of 2 knockouts and install 1/2” conduit

connector in j-box.

4.   Run black, white, and green wires (#18 AWG) in

1/2” conduit from power supply to j-box.

5.   Connect the black to black (hot line) wire, white to

white (common line) wire and green/yellow wire
to ground in j-box cover.

6.   Close j-box cover. 

7.  For ES36 only: mount the filter trim bracket

supplied on the right side of the hood. Check that
all engage points perfectly match, then fix with 3
screws as shown in figure 12.

Final installation steps 

Replace filters and grease trays as described in the
Use & Care  manual. Turn power on at service panel.
Check operation of the hood.

Bracket

Motor

connector

Spring clip

Integral ventilator
fixing point

Power
supply
conduit

From
control
panel

Motor

support

FIG. 11

FIG. 10

FIG. 9

FIG. 12

SCREW
LOCATIONS

Содержание Vent Hood ES30

Страница 1: ...THE PROFESSIONAL AND EURO VENT HOOD Installation Guide MODELS VS30 VS36 VS48 RDS 364GD VS1236 ES30 ES36 486GD...

Страница 2: ...on the inner back panel behind grease filters below motor assembly MODEL NUMBER CODE SERIAL NUMBER WARNING If the information in this manual is not followed exactly a fire or explosion may result cau...

Страница 3: ...persons in the event of a rangetop grease fire observe the following Turn burner off first Smother flames with a close fitting lid cookie sheet or metal tray Be careful to prevent burns If the flames...

Страница 4: ...ent air is needed to maintain proper combustion and safe exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturers guide...

Страница 5: ...etal tray then turn off the gas burner or the electric element BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN y...

Страница 6: ...pipe DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in electrical shock Check with a qualified electrician if you are in doubt as to whe...

Страница 7: ...12 Duct Cover Accessory Height ES30 14 15 16 ES36 17 15 16 12 6 25 2 18 6 or 12 Duct Cover Accessory Height VS30 29 7 8 VS36 VS1236 35 7 8 VS48 47 7 8 VS30 29 7 8 VS36 VS1236 35 7 8 VS48 47 7 8 VS30 1...

Страница 8: ...ral Blower PARTS NOT INCLUDED WITH YOUR HOOD Ducting See Page 9 for duct requirements 8 or 10 to be used Duct Tape 1 2 Conduit Wire Nuts Optional duct cover 6 or 12 height VDC1230 12 Duct cover kit fo...

Страница 9: ...cific requirements in your area 7 Hood installation height above cooktop is the users preference Lower installation heights will improve the efficiency of capturing cooking odors grease and smoke This...

Страница 10: ...36 are supplied with a starting collar and backdraft damper on top of the hood for connection to 8 round duct Models VS1236 and VS48 are supplied with a 10 round transition with damper and is assemble...

Страница 11: ...uct covers can be joined together in any combination 1 Hood Installation Height After the hood installation height has been determined draw a horizontal line at a distance above the cooktop equal to t...

Страница 12: ...tud 7 Use 2 to 4 1 4 x 3 flat head wood screws to attach the bracket to the wall as shown in Figure 4 For support of longer hoods use three or four studs as available Countersink the heads to prevent...

Страница 13: ...screws and seal with duct tape Screws must not hamper the damper 15 Drill a 3 8 hole through the center of the holes K into the wall Insert two wall plugs into drilled holes Tighten hood to wall anch...

Страница 14: ...H G I 1 1 2 Dia Holes Vertical conduit option A B C D E F G H I Min 12 6 10 6 3 4 1 7 8 5 3 4 5 7 8 1 7 8 5 1 8 ES30 30 ES36 36 C L Cabinet Vertical Discharge Cutout Width Bottom of Cabinet or Soffit...

Страница 15: ...pace of about 1 2 from cabinet bottom surface and screw heads 4 Hang the hood on screws through side slots provided on hood top Tighten the four screws Drill a 3 8 hole through the center of the holes...

Страница 16: ...e j box cover as shown in Figure 11 3 Remove 1 of 2 knockouts and install 1 2 conduit connector in j box 4 Run black white and green wires 18 AWG in 1 2 conduit from power supply to j box 5 Connect th...

Страница 17: ...nd grease filters below motor assembly Serial Number located on the inner back panel behind grease filters below motor assembly Code located on the inner back panel behind grease filters below motor a...

Страница 18: ...r of attempts at our option we may replace the part or the Product or we may provide you a full refund of the purchase price of the Product not including installation or other charges This warranty ex...

Страница 19: ...limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you HOW TO GET SERVICE Please read your Use and Care Guide If you then have any questions about...

Страница 20: ...dcsappliances com As product improvement is an ongoing process we reserve the right to change specifications or design without notice Nous am liorons constamment ses produits et se r serve le droit d...

Отзывы: