14
INSTALLATION
CAVITY DIMENSIONS
BE1-48R
BE1-36R
Inches (mm)
Inches (mm)
A
Maximum height of enclosure shell
35 1/2" (902)
35 1/2" (902)
B
Depth of enclosure shell
22 3/4" (578)
22 3/4" (578)
C
Minimum depth for hood swing
3 3/4" (95)
3 3/4" (95)
D
Width of enclosure cavity
51 5/8" (1318)
40 1/2" (1029)
E
Height of enclosure cavity
11 1/8"(283)
11 1/8"(283)
f
Depth to gas supply opening
18 1/2"(464)
18 1/2"(464)
G
Height to base of vents
1" (25)
1" (25)
H
Height of opening for access doors/drawers
20" (508)
20" (508)
I
Width of opening for access doors/drawers
46" (1168)
34" (864)
ACCESS DOORS
MODEL NUMBER
ACCESS DRAWERS
MODEL NUMBER
CAVITY WIDTH
CAVITY HEIGHT
Inches (mm)
Inches (mm)
ADN1-20x48
ADR2-48
46" (1168)
20" (508)
ADN1-20x36
ADR2-36
34" (864)
20" (508)
ADN1-20x30
ADR2-30
28" (711)
20" (508)
ADN1-20x24
ADR2-24
22" (559)
20" (508)
D
E
H
I
G
F
A
B
C
Built-in Construction Details
Standard layout for cavity including insulated jacket
Note: vents are to be located at the left,
right and rear of the enclosure. Minimum
size of all vents is 10x10" (645mm x 645mm)
Note: the cut-out of each
corner should be a 90°angle
in order for the access doors/
drawers to fit properly.
Note: 4x4” (102mm x 102mm)
opening for gas supply line
FIG. 06
To order access drawers or doors, please visit www.dcsappliances.com for further details.
Содержание BE1-36R
Страница 2: ......
Страница 8: ...6 BE1 36R BE1 48R GRILL MODELS ...
Страница 25: ...EN ...
Страница 48: ......
Страница 54: ...6 BE1 36R BE1 48R GRILL MODÈLES ...
Страница 71: ...FR ...
Страница 94: ......
Страница 95: ......