090 Series Reference Manual
2/21/05
Digital Control Systems
Page: 8
INSTALLATION
This section covers the major points to consider when incorporating the 090 series into the end
product's design.
Main ECB Electrical Connections
J5
AUXILIARY POWER
ECB CONNECTOR
J4
PRIMARY POWER
ECB CONNECTOR
OPTION
JUMPERS
(JP1 & JP2)
J8
SENSOR INPUT
J6
OPTION PORT
Components and traces in
crosshatched area have
potentially lethal voltages present
while unit is under power.
CONTROLLER
POWER INPUT
80 - 280 VAC
45 - 65 Hz
Figure 2
: 090 Main ECB Part Locations (Viewed from rear)
Sensor Connection
The sensor is connected to the two pin header J8 located at the bottom of the power board as
shown in
. The exact sensor type is determined by the controller configuration. The
sensor cable should not be routed near power carrying wires to minimize noise pick-up.
Power Line Connection
The controller’s operating power is connected at the three ¼” quick connect tabs located on the
left hand edge of the main ECB as shown in
. Beware that traces and components in the
area shown crosshatched in
can have potentially lethal voltages to ground and each
other while the unit is under power.
If one leg of the power supply is grounded (i.e. neutral for domestic applications) it should be
connected to the power tab marked ‘NEUT’, since the ‘HOT’ terminal is the fused input.