background image

PSX-AR Manual Rev: P      Software Rev: N 

19 

 

K. Special Programming Instructions

  

Specific DCC Systems need to follow specific programming sequences to reliably 
program a PSX-AR. See Section M for specific system instruction 

All systems:

 

Program CV’s using POM. Do not use Program track or accessory 

programming.

 

Digitrax:

 

Install the Digitrax Configuration Jumper wire from Terminal

 

J7.3 to J7.4

 

By installing the Digitrax Configuration jumper connection, all aspects of the PSX-AR series 
are optimized to operate with Digitrax equipment. This includes the DCS50, DCS51, DCS100, 
DCS200, DCS210, DCS240 and the associated booster only units. As a result of these 
changes, it is recommended that any layout using Digitrax equipment should install this 
jumper. Note that the configuration jumper does NOT affect the trip current setting. You will 
still need to select the trip current you want to use. 

When the J7-3 & J7-4 jumper is installed and the PSX-AR is placed in Program mode, the 
default addresses of the PSX-AR are automatically changed to allow the Digitrax system to 
access these functions directly: 

 

997 [on/off – first address] 

 

998 [photo cell arm – second address] 

 

999 [switch control PSX-AR only – third address] 

If the PSX-AR  is reset [CV63=42], the default address will be  2042, 2043 & 2044. These 
addresses are not accessible to the Digitrax equipment. Under this condition it is necessary 
to: 

1.  Remove power from the PSX-AR while in Program mode 
2.  Re-apply the power in Program mode with the Digitrax Configuration jumper on pins 

J7-3 & J7-4 

3.  This will program the Digitrax default addresses again [997, 998, 999] 

Note that if the J7-3 & J7-4 jumper is absent and the PSX-AR is placed in program mode, the 
997, 998, & 999 sequence will be changed back to the normal default of 2042, 2043, & 2044. 
If the PSX-AR has been programmed to an address other than one of the two default address 
sequences, the presence or absence of the jumper will have no effect on the stored 
addresses.  

At power up, Digitrax systems place several commands on the track bus intended for use by 
other Digitrax accessories. These signals appear to the PSX-AR as an accessory address. In 
order to prevent these addresses from incorrectly programming the PSX-AR, a PSX-AR will 
not accept a command to program an accessory address above 999 when the Digitrax 
Configuration Jumper is installed. 

With the Digitrax Configuration Jumper installed, the PSX-AR  uses a different turn on 
algorithm that enhances the ability of the Digitrax equipment to turn on multiple sound 
decoders without difficulty.

 

 
 
For all systems, whenever you enter an address or CV value, you should see D6 flash. This indicates 
the PSX-AR has received the information, stored it, and verified the stored data match the data you sent. 

Содержание PSX-AR

Страница 1: ...Coordination of Auto Reverse and Circuit Breaker Tasks The PSX AR is both an auto reverser and circuit breaker Automates Reverse Loop Turnouts Integrated Stall Motor or Snap Coil Decoder automaticall...

Страница 2: ...mmand or to use the power status present when the layout was last shut down Outputs for LED Indicators Remote LEDs can be added to monitor input output power status Network Feedback Isolated outputs d...

Страница 3: ...est the PSX AR for functionality a Turn on DCC power to the PSX AR b The PSX AR should turn on with both D12 and D7 indicating power and D6 off c Take a piece of wire and connect J1 1 to J2 3 Nothing...

Страница 4: ...rn screw on connector s counter clockwise while looking at the connector opening b Make sure the wire clamp is at the bottom of the connector opening c Insert the wire you are connecting and turn the...

Страница 5: ...test D12 stays on 13 If your booster does trip during this test D12 goes off or flashes on and off it may not be able to support automatic reset a Install the Manual Reset jumper J7 1 to J7 2 and rep...

Страница 6: ...efficient motors this type of power requirement amps may be large enough to overload a DCC system powered from one 5 Amp booster For example if you have four PSX set to the default current each PSX w...

Страница 7: ...HO Scale 14 AWG bus 20 AWG rail feeders O Scale 12 AWG bus 16 AWG rail feeders We recommend using stranded pair wire such as speaker or lamp cord wire for bus wiring If you re using two individual str...

Страница 8: ...r Input A from DCC Booster J1 2 DCC Power Input B from DCC Booster J2 Output Power Connector J2 1 3 5 Switched DCC Power Output A normal polarity J2 2 4 6 Switched DCC Power Output B normal polarity J...

Страница 9: ...Status LED copies D6 J5 4 cathode Remote Status LED copies D6 Select such that gaps closest to aligned point direction are in phase J6 Trip Current Settings by Jumpers See Table to the right and also...

Страница 10: ...D7 G Terminal Functions J1 DCC power input connections from the DCC booster J2 DCC track power output terminal from the PSX AR circuit breaker to the track J3 Programming Operation jumper Normal opera...

Страница 11: ...6 3 and J6 2 to J6 1 is open then the current trip is 6 35 amperes If J6 4 is connected to J6 3 and J6 2 is connected to J6 1 then the current trip is 8 89 amperes J7 1 and J7 2 are the auto manual re...

Страница 12: ...urn power on to the PSX AR 5 The next accessory command issued by the DCC system will be stored as the first address track on off 6 Key in the first address you want to use and press either the ON or...

Страница 13: ...ow you to stop a train at a known point on a hidden staging track As the train enters the staging or other track you issue the photocell arming command When the train just covers the photocell the PSX...

Страница 14: ...rectly synchronized otherwise the PSX AR will throw the points under your train as it enters the reverse loop Send an accessory Clear command to the PSX AR If the points move to the Throw position the...

Страница 15: ...by the value The small red LED D6 on the PSX AR will blink each time a command is accepted and the CV value is stored correctly in the CV 8 If you make a mistake don t worry just go back and program...

Страница 16: ...ectively with Digitrax equipment Installing the Digitrax jumper J7 3 to J7 4 automatically sets CV53 1 CV54 sets the current level at which the PSX AR turns on the Block Occupied output This allows yo...

Страница 17: ...t Using the Program On Main POM programing mode of your DCC system set CV63 42 You will see D6 flash After D6 flashes all CVs and addresses are returned to their original factory values The CV63 defau...

Страница 18: ...ss of the value in CV50 CV66 2 The PSX AR output will assume the same state it was in when the connected booster was last turned off o If the stored power down state is OFF the PSX AR will behave the...

Страница 19: ...044 These addresses are not accessible to the Digitrax equipment Under this condition it is necessary to 1 Remove power from the PSX AR while in Program mode 2 Re apply the power in Program mode with...

Страница 20: ...o this address and hold down the 1 or 4 control key 7 D10 will flash each time the command station repeats the accessory address This will give you a feel of how long to hold the control key while you...

Страница 21: ...e is a simple circuit that uses an LED to indicate the polarity setting of the PSX AR It only uses three standard parts If you have block occupancy detection circuits the resistor value should be high...

Страница 22: ...the PSX 5 Select an unused locomotive number with the keypad or RH knob 6 Press PROG key until you get from Pg to Po 7 Use LH throttle dial to set the CV and the RH throttle for the CV value 8 Press E...

Страница 23: ...itch number using the numerical keypad 6 Press ENTER 7 Press either 1 or 2 to set the address 8 Repeat steps 4 thru 6 until all of the switch addresses are set 9 Turn DCC Power off 10 Move PSX J3 Jump...

Страница 24: ...display 8 Enter the CV number 9 Press ENTER 10 Enter the value to be stored in the CV 11 Press ENTER 12 Repeat steps 8 and 9 until finished 13 Press ENTER to return to normal operation 14 Turn power o...

Отзывы: