background image

13

Issue Date: 18/04/13          Issue No: 5

Uni 8™ evolution™ Overhead Horizontal Lifeline System

System Layout & Components

Section 9.0

7234021

Uni 8™ Wall Fixing Plate 

7240122

Uni 8™ Straight Eye

7241073

Uni 8™ Energy Absorber 

7240109

Uni 8™ 8mm Hex Swage Tensioner 
5kN

A

B

C

D

7241067 

Uni 8™ Overhead Intermediate 
Bracket

7240212

8mm 1 x 19 Stainless Steel Cable

7234011

Uni 8™ 8mm Hex Swage Toggle

E

F

G

H

EN795:1996 Class C
OSHA COMPLIANT
AS/NZS 1891.2

Installation Date / Installatiedatum / Fecha de instalación / Montagedatum /Date d’installation / Data da instalação / Data installazione / Installationsdatum

Installed By / Geïnstalleerd door / Instalado Por / Montiert durch / Installateur / Instalado por / Installato da / Installerad av

Contact Number / Contactnr. / Tel. de contacto / Kontakttelefon / Téléphone / Nº de Contacto / Numero contatto / Kontaktnummer

Min. Ground Clearance (m) / Min. vrije valruimte (m) / Distancia minima hasta el suelo (m) / Mindestabstand zum Boden (m) / Hauteur libre minimale (m) / Altura mínima livre (mt) / 

Distanza libera minima da terra (m) / Min. höjd ovanför marken

Max. Users Per System / Max. aantal gebruikers per systeem / Máximo de usuarios por sistema / Maximale Benutzer pro System / Nombre maximal d’utilisateurs par 

système / Nº máximo de utilizadores por linha / N. utenti max. per sistema / Max. användare per system

Max. Users Per Span / Max. aantal gebruikers per overspanning / Máximo de usuarios por vano / Höchstzahl der Benutzer pro Spannweite / Nombre maximal 

d’utilisateurs par portée / Nº máximo de utilizadores por vão / N. utenti max. per sezione / Max. användare per skena

Next Service Date / Datum volgende keuring / Próxima fecha de revisión / Termin der nächsten Wartung 

/ Prochaine date d’entretien / Data da próxima Inspecção / Data prossima manutenzione / Nästa 
servicedatum

System Serial No. / Serienummer / Número de serie del sistema / Seriennummer des Systems / Numéro de série / Nº de série do sistema / N. di serie sistema / Systemets 

serienr.

Use Energy Absorbing Lanyards / Gebruik energie-absorberende verbindingslijnen / Utilice acolladores de absorción de energía / Verwenden Sie falldämpfende 

Sicherheits-/Anschlagseile / Utilisez des longes à absorption d’énergie / Usar cordas com amortecedor de energia / Utilizzare funi ad assorbimento d’energia / Använd 

energiupptagande taljerep

www.capitalsafety.com 

5A Merse Road

North Moons Moat

Redditch

Worcestershire

B98 9HL 

2013

INTERTEK  ITS10ATEX17038

Technical File No. 70802

Capital Safety Group

II  2  G  c  IIC T3

TM

7241257

Uni 8™ System Tag 

7240175

Uni 8™ evolution™ Triple Articulaed 
Anchorage Point

7240151

Uni 8™ evolution™ High Capacity 
Energy Absorber

7240118

Uni 8™ evolution™ Overhead 
Intermediate Bracket

I

J

K

L

7240100

Uni 8™ evolution™ Traveller

7240211

8mm 7 x 7 Stainless Steel Cable

7240137

Uni 8™ evolution™ Overhead Curve

M

N

O

7241074

Uni 8™ Overhead Traveller

Содержание Uni 8 Overhead

Страница 1: ...T H E U L T I M A T E I N F A L L P R O T E C T I O N USER INSTRUCTION MANUAL Uni 8 Overhead Always read and follow the warnings and instructions for use Copyright Capital Safety Systems Ltd 2013 ...

Страница 2: ... 4 3 0 SYSTEM DESIGN INSTALLATION AND OTHER CHARACTERISTICS 5 4 0 REGULATIONS QUALITY PRECAUTIONS AND EXCLUSIONS 6 5 0 INSPECTION MAINTENANCE SERVICING AND WARRANTY 7 6 0 PRE USE CHECKS 8 7 0 USING THE SYSTEM 9 8 0 FOLLOWING INSTALLATION 11 9 0 SYSTEM LAYOUT COMPONENTS 12 10 0 MAINTENANCE CHECK SHEET 14 11 0 RESCUE EMERGENCY PROCEDURES 15 ...

Страница 3: ...ns and general requirements of the system Further details of the specific limitations of your system will be provided by your Approved Systems Integrator Users must be competent personnel who have read and understood this manual and have been trained by an approved person It is recommended that the System is not used by lone operatives for reasons of safety and that a rescue plan must be in place ...

Страница 4: ...f otherwise dangerous situations or to restrain personnel from putting themselves at risk The Uni 8 Overhead System consists of a horizontally mounted lifeline that spans the work area and is fixed at either end to the structure via anchorage connectors The lifeline may be supported at regular intervals by intermediate brackets The intermediate brackets help to reduce the loads in the event of a f...

Страница 5: ...certification and maintenance of the product If you are at all concerned about the competence of the personnel installing your system please contact Capital Safety 3 3 FIXINGS The Capital Safety Simulation Program calculates figures for the loads that would be generated in the event of a worst case fall scenario It is imperative that the supporting structure and fixings used in the construction of...

Страница 6: ...rtified and marked in accordance with the relevant national standard Using the wrong PPE or lanyards of incorrect length can result in injury or death Each system installed will be supplied with specifications of full body harness lanyards and shock absorbers or self retracting fall arrest devices The following precautions and exclusions apply The Uni 8 Overhead System must be installed by an Appr...

Страница 7: ...tional standards the Uni 8 Overhead Horizontal Lifeline System should be inspected at least once a year In high use applications or aggressive environments Capital Safety strongly recommends that the servicing interval should be more frequent As the Uni 8 Overhead Horizontal Lifeline is a unique safety product only Approved Capital Safety Systems Integrators or persons trained by the manufacturer ...

Страница 8: ...ice is secured on after the initial installation of the safety line A Maximum of 1 user weighing no more than 140kg 310lbs may attach themselves to one device Subject to system weight restrictions The attachment device in conjunction with a correctly installed system will allow smooth passage by the user along the system Check that the carriage runs smoothly prior to use If the carriage does not r...

Страница 9: ...d and that a rescue can be facilitated within 15 minutes or sooner of the fall occurring It is strongly recommended that users do not work alone incase of an incident 7 2 USER EQUIPMENT Always wear a full body harness The user should attach their fall arrest device to the rear D ring of the harness This prevents the fall arrest device getting in the way during movement and in the event of a fall e...

Страница 10: ...more than 20 degrees each side of the centre of the during use This will ensure continued functionality and prevent dangerous swing fall hazards 7 5 DETACHING FROM THE SYSTEM Only detach yourself from the system when in a position of safety Remove the fall arrest device connector from your harness and when using self retracting fall arrest devices or controlled rate descent devices slowly feed the...

Страница 11: ...y service The name and contact details of the installation company The name of the installation engineer and or supervisor A representative of the installation company should sign the certificate 8 3 SYSTEM LABEL The System Label must be located at the entrance point to the System It must contain the following information The maximum number of users per span and per system The maximum lanyard leng...

Страница 12: ...gedatum Date d installation Data da instalação Data installazione Installationsdatum Installed By Geïnstalleerd door Instalado Por Montiert durch Installateur Instalado por Installato da Installerad av Contact Number Contactnr Tel de contacto Kontakttelefon Téléphone Nº de Contacto Numero contatto Kontaktnummer Min Ground Clearance m Min vrijevalruimte m Distanciaminimahastaelsuelo m Mindestabstan...

Страница 13: ...system Max Users Per Span Max aantal gebruikers per overspanning Máximo de usuarios por vano Höchstzahl der Benutzer pro Spannweite Nombre maximal d utilisateurs par portée Nº máximo de utilizadores por vão N utenti max per sezione Max användare per skena Next Service Date Datum volgende keuring Próxima fecha de revisión Termin der nächsten Wartung Prochaine date d entretien Data da próxima Inspec...

Страница 14: ...ntermediate brackets are not deployed and nylon shear pins are intact RoofSafe Anchors Check energy absorbing elements are not deployed Ensure all waterproofing elements are present and intact Check standing seam clamps with a torque wrench RAIL SYSTEMS Check system carriage and end stops are securely fixed Check system for cracks in rail Check rail for signs of deformation Roofsafe rivets hand ch...

Страница 15: ...cue The importance of having a rescue plan to deal with such emergencies cannot be overemphasized Such a plan includes consideration of rescue equipment personnel and training as necessary It is not acceptable just to rely on the emergency services Emergency procedures need to be considered for reasonably foreseeable circumstances The measures need to be covered in the risk assessment and planned ...

Страница 16: ...orkers in the field We employ the best engineers to create innovative solutions and patent the products that keep workers safe at heights around the world Capital Safety has the best quality and largest range of fall protection products in the industry But we re more than a product company We take an innovative approach in bringing our products to the field We have created international partnershi...

Отзывы: