background image

I  S  O

9 0 0 1

Certificate No. FM 39709

From: 5902140
Rev : 

G

Capital Safety

3

833 SALA Way

Red Wing, MN 55066-1837

Distributed by Engineered Fall Protection

Email: [email protected]

Web: www.engineeredfallprotection.com

PH: 314-492-4422  |  FAX: 800-570-5584

WARRANTY

Equipment offered by DBI/SALA is warranted against factory defects in
workmanship and materials for a period of two years from date of installation
or use by the owner, provided that this period shall not exceed two years
from date of shipment. Upon notice in writing, DBI/SALA will promptly
repair or replace all defective items. DBI/SALA reserves the right to elect
to have any defective item returned to its plant for inspection before making
a repair or replacement. This warranty does not cover equipment damages
resulting from abuse, damage in transit, or other damage beyond the control
of DBI/SALA. This warranty applies only to the original purchaser and is
the only one applicable to our products, and is in lieu of all other warranties,
expressed or implied.

Содержание 8001717

Страница 1: ...complete system These instructions must be provided to the user of this equipment The user must read and understand these instructions or have them explained to them before using this equipment Manufa...

Страница 2: ...3 Figure 1 8001717 and 8001718 Parts Identification...

Страница 3: ...4 Figure 2 8000000 and 8000010 Parts Identification...

Страница 4: ...ounting bracket for DBI SALA Salalift Winch or Self Retracting Lifeline IMPORTANT For special custom versions of this product follow the instructions herein If enclosed see attached supplement for add...

Страница 5: ...uipment is designed for use with DBI SALA approved components and subsystems only Substitutions or replacements made with non approved components or subsystems may jeopardize compatibility of equipmen...

Страница 6: ...at are not shaped in a way that can capture the gate of the hook C In a false engagement where features that protrude from the snap hook or carabiner catch on the anchor and without visual confirmatio...

Страница 7: ...of at least A 3 600 lbs 16kN when certification exists see ANSI Z359 1 for certification definition or B 5 000 lbs 22 2kN in absence of certification When more than one tripod is installed on a struct...

Страница 8: ...escue system when in use Each tripod installation must independently sustain this load 3 0 OPERATION AND USE WARNING Do not alter or intentionally misuse this equipment Consult DBI SALA when using thi...

Страница 9: ...secondary or back up fall arrest system is required See OSHA 29 CFR 1910 28 and 1926 451 The tripod has provisions for connection of a secondary or back up personal fall arrest system See sections 3...

Страница 10: ...tments The footing must be solid under each leg and support the intended loading Position the tripod such that the lifeline will be directly over the intended work area when installed Do not position...

Страница 11: ...12 Figure 5...

Страница 12: ...d to either one of the eye bolt anchorage points See Figure 6 Connect equipment to the eye bolt anchorage point by using a clevis and pin minimum breaking strength of 5 000 lbs self locking carabiners...

Страница 13: ...etracting Lifelines D HEAD MOUNT PULLEYS The 8000000 and 8000010 model tripods come equipped with head mounted pulleys These pulleys should be used for mounting the line of the primary use system over...

Страница 14: ...are limited to one system IMPORTANT Knots must not be used for load bearing end terminations see ANSI Z359 1 Some knots reduce the strength of the lifeline by 50 percent or more 4 0 TRAINING 4 1 It i...

Страница 15: ...16 Figure 9 Two Salalift Winches Mounted to Tripod Lifelines routed through Head Mount Pulley and Leg Mount Pulley...

Страница 16: ...17 Figure 10 Salalift Winch and Self Retracting Lifeline Mounted to Tripod Lifelines routed through Head Mount Pulley and Snatch Block Pulley...

Страница 17: ...k into place when tripod is erect Step 3 Check the feet on each leg ensure they pivot and the rubber pad is in place Step 4 Check leg chain and connections Ensure they are tight and undamaged chain mu...

Страница 18: ...rding to separate instructions provided with that equipment 6 4 Store this equipment in a cool dry clean environment out of direct sunlight Avoid areas where chemical vapors may exist Inspect after an...

Страница 19: ...ments The 8000000 and 8000010 are U L classified See product label for details 8 0 LABELING 8 1 The following labels must be present and fully legible Warning Label Models 8001717 and 8001718 Specific...

Страница 20: ...21 Figure 11 Geometric Requirements...

Страница 21: ...v o r p p A y B d e v o r p p A y B d e v o r p p A y B d e v o r p p A y B d e v o r p p A y B d e v o r p p A y B d e v o r p p A y B d e v o r p p A y B d e v o r p p A 9 0 INSPECION AND MAINTENAN...

Страница 22: ......

Страница 23: ...ion or use by the owner provided that this period shall not exceed two years from date of shipment Upon notice in writing DBI SALA will promptly repair or replace all defective items DBI SALA reserves...

Отзывы: