87 /87
In the TRAP TYPE box select the message type desired, trap or inform. If inform is selected, the
timeout the agent waits (if no answer from the manager) before re-send the inform message can be
set in the INFORMS TIMEOUT box, the number of inform retransmission can be set in INFORMS
RETRIES box.
The messages trap/inform have to be enable and can be enable singly. The enable is provided to the
OIDs (fmSTEventEnable folder):
EVENT
OID
DESCRIPTION
fmSTTransmitterOpModeEventEnable
.1.3.6.1.4.1.19831.1.1.3.1.2.1.1
1=Enable, 2=Disable
fmSTRFPresentEventEnable
.1.3.6.1.4.1.19831.1.1.3.1.2.1.2
1=Enable, 2=Disable
fmSTFaultEventEnable
.1.3.6.1.4.1.19831.1.1.3.1.2.1.3
1=Enable, 2=Disable
fwSTWarningEventEnable
.1.3.6.1.4.1.19831.1.1.3.1.2.1.4
1=Enable, 2=Disable
fmSTLocalModeEventEnable
.1.3.6.1.4.1.19831.1.1.3.1.2.1.5
1=Enable, 2=Disable
8.3.3
COMMANDS AND STATE
Commands and State available through SNMP are summed in the following table:
EVENT
OID
TYPE
DESCIPTION
fmSTTransmitterOpMode
.1.3.6.1.4.1.19831.1.1.3.1.1.1
Read and Write
1=ON, 2=OFF
fmSTRFPresent
.1.3.6.1.4.1.19831.1.1.3.1.1.2
Read only
1=Present, 2=Not Present
fmSTFault
.1.3.6.1.4.1.19831.1.1.3.1.1.3
Read only
1=Fault, 2=No Fault
fwSTWarning
.1.3.6.1.4.1.19831.1.1.3.1.1.4
Read only
1=Warning, 2=No Warning
fmSTLocalMode
.1.3.6.1.4.1.19831.1.1.3.1.1.5
Read only
1=Local, 2=Remote
The commands are accepted by the unit only in remote mode and if the community strings are
correctly set for both read and write operations.
The community read/write strings have to be set both to the agent and manager units. In the
webpage can be set in the Administration menu.