dB Technologies OPERA UNICA 12 Скачать руководство пользователя страница 3

www.dbtechnologies.com

 [email protected]

 

 

 

OPERA UNICA 12 

 

cod. 420120269Q REV.1.0 

3) Connections and controls 

All  the  connections  and  controls  are  in  the  amplifier 
panel side: 

 

1

–Balanced input (XLR connector type) 

2

–Input sensitivity control 

3

–Input sensitivity type switch (MIC/LINE) 

   

4

–Balanced output Link (XLR connector type) 

   

5

–Status LEDs (

Limiter-Signal-Status-ON

6

–DSP Preset rotary with reference table 

7

–RDNet DATA IN 

8

–RDNet DATA OUT 

9

–RDNET control LEDs  

10

–USB Data Service 

11

–Auto-range Mains Input 

12

–Mains Link 

13

–Mains Fuse 

a) Connect  the  audio  input  [

1

].  In  case  of  dynamic 

microphone, select “MIC” in input sensitivity switch [

3

], 

otherwise  select  “LINE”.  Adjust  the  Input  Sensitivity 
level [

2

]. 

b) If  you  need  to  send  the  audio  signal  to  a  second 
speaker,  connect  the  “Balanced  Output”  [

4

]  to  the 

Input on [

1

] of another OPERA UNICA 12 (for example) 

using a cable with XLR (balanced) connector. 
c) Set  properly  the  DSP  preset  rotary  [

6

],  choosing 

between on stand “

S

”, wedge “

W

” configurations, or 

apply HPF filters “

H

”. The settings possibilities are: 

 

S1

– Playback, for tracks (like mp3 

reproduction) 

S2

– Bass boost, with a low-frequencies 

enhancement   

S3

– Vocal enhance, for an optimization in 

vocal and singing performances    

H1 – 

HPF 90 Hz

 - 

Apply high-pass filter with 90 

Hz cutoff frequency, for a little bass reduction 

H2 – 

HPF 120 Hz - Apply high-pass filter with 

120 Hz cutoff frequency, for a strong bass 
reduction 

W1

– Wedge, designed for reproduction in 

monitoring (wedge) use 

FLAT 

– designed for coherent source 

reproduction  
 

d) In case of remote control, connect the proper Data 
Input  [

7

]  to  the  hardware  remote  controller  (RDNet 

Control  2  or  RDNet  Control  8)  with  cables  equipped 
with  etherCON  connectors.  Then  connect  the  Data 
Output  [

8

]  to  the  Data  Input  [

7

]  of  a  second  OPERA 

UNICA, and so on. When the RDNet network is on and 
it has recognized the connected device, the LED “Link” 
[

9

] is on. The other LED [

9

] “Active” start blinking when 

there  is  the  presence  of  data  transmission,  the 
“Remote  Preset  Active”  advise  that  all  the  local 
controls set on the amplifier panel (level, DSP presets, 
etc.)  are  by-passed  and  controlled  remotely  by  the 
software  AURORA  NET.  See  also  RDNet  Control  2, 
Control 8 and  AURORA NET user manuals for further 
information. 
 
e) Plug the mains Input [

11

] and Link [

12

] (powerCON) 

cables. The Signal/ON led starts blinking, signaling the 
presence of audio signal. 

Check the complete user manual on 

www.dbtechnologies.com 

for further 

information about the system and available accessories. 

Scarica  il  manuale  completo  da 

www.dbtechnologies.com

 

per  ogni 

ulteriore informazione sul sistema e sugli accessori disponibili. 

Für  weitere  Informationen  und  verfügbares  Zubehör  lesen  sie  bitte  die 
vollständige Bedienungsanleitung unter

 

www.dbtechnologies.de

.

 

Vérifiez le manuel de l'utilisateur complet sur 

www.dbtechnologies.com

 

pour  des  informations  complémentaires  du  système  et  des  accessoires 
disponibles. 

Compruebe 

el 

manual 

de 

usuario 

completo 

sobre 

www.dbtechnologies.com

 para la información adicional sobre el sistema 

y accesorios disponibles.

 

  

WARNING 

  The speaker is supplied with a mounted fuse for operation within the 
  220-240V~ range. If you need to operate in the 110-120V~ voltage range: 
  1. Disconnect all connections, including the power supply.  
  2. Wait for 5 minutes.  
  3. Replace the fuse with the one provided in the package  
       for the 100-120V~ range

 