background image

02

GAIN (6V ~ 0.2V)

Matching the output voltage of the headunit’s RCA 

line-outs to OKUR amplifiers’ input section.

SUBSONIC FILTER (10Hz ~ 50Hz @ 24dB/Oct)

Control the high Pass point for the speaker outputs 

to eliminate extreme low frequencies that can 

damage your subwoofers.

BASS BOOST (0~9dB @ 45Hz)

It boosts the bass 0 ~ 9dB

REMOTE LEVEL CONTROL PORT

This port is for connecting remote gain level control

LOW PASS FILTER (35Hz ~ 250Hz @ 24dB/Oct )

Controls the low pass point for the speaker outputs.

PHASE (0 ~ 180 degree )

It controls phase from 0 ~ 180 degree.

OUTPUT MASTER / INPUT SLAVE

OUTPUT MASTER / INPUT SLAVE connection makes

OKUR Competition amplifiers as daisy china connection

to 2 ohm.

+12V (POWER CONNECTION)

This must be connected to the fuse positive terminal

(+12V) of the battery.

Recommenede wire is 0 gauge for A7 3500L.1, 

A7 3500H.1 & A7 7500.1.

Check the battery voltage.

GND ( GROUND CONNECTION )

It is connected to the Negative or ground cables of

the vehicle. 

Recommenede wire is 0 gauge for A7 3500L.1, 

A7 3500H.1 & A7 7500.1.

REM (REMOTE)

It is connected to sw12V with a trigger cable

coming from the head unit.

SPEAKER OUTPUTS 

It connects amplifier’s terminal to subwoofer

speakers.

Minimum speaker wire is 12 gauge.

Minimum impedance is 1 ohm for single unit.

Linked connection’s minimum impedance is 2 ohm.

3. INSTALLATION

In case you install the OKUR Competition amplifiers by yourself, please read owner’s manual very carefully.

before your installation. please take all steps into consideration. or, you can have DB Drive or DB Research’s

authorized dealer to check installation and set your car audio systems. 

3-1. MOUNTING PREPARATION

Disconnect the negative ( - ) battery cable before mounting your OKUR competition amplifiers or making any

connections. Check the battery and alternator ground ( - ) connections. Make sure they are properly connected

and free of corrosion before selecting a mounting location. Please take some concerns into consideration

with cooling efficiency and safety.

3-2. MOUNTING PREPARATION

The OKUR competition amplifiers use a spcially designed heat radiation heatsink to avoid excessive heat

from OKUR circuitry. But for better heat dissipation, it is good to find the mounting location where you can install

OKUR vertically with the heatsink fins and better air flow around heatsink.

For the safety, You have to find a dry and well ventilated location and make sure any cables and drilling car

equipment are not interfere with mounting location. Be sure the mounting location and drilling of pilot cables

will not present a harzard to any cables, control cables, fuel lines, fuel tanks, hydraulic lines or other vehicle

systems or components.

3-3. +12V, GND, REM CONNECTION.

12V ( POWER CONNECTION )

Before mounting OKUR competition amplifiers, disconnect the negative ( - ) wire from battery to protect any

accidential damage to amplifier and audio system. A7 3500L.1. A7 3500H.1 and A7 7500.1 are designed to

use minimum 0 gauge cables.

Connect the power cables to power terminal labeled as +12V. A7 3500L.1, A7 3500H.1 and A7 7500.1 are

not equipped with fuses so you need to install external fuses.

In order to install external fuses, connect one end of fuse holder to the power cable and the other end of 

fuse holder to positive battery within 18in of the same cable gauge. This fuse location will protect the system

and the vehicle against the possibility of a short circuit in the power cable. 

Be sure to use fuses and fuse holders adequate for the current draw application.

www.dbdrive.net

Содержание A7 3500H.1, A7 3500L.1, A7 7500.1

Страница 1: ...7 3500H 1 A7 3500L 1 A7 7500 1 User Manual Installation Instructions Owner s Manual www dbdrive net DUE TO CONTINUOUS IMPROVEMENT OF THE PRODUCT THE SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE...

Страница 2: ...y connection or thermal protection Load 4ohm 2ohm 1ohm Voltage THD 14 4 volts 1 14 4 volts 1 14 4 volts 1 A7 3500H 1 1 X 900 1 X 1800 1 X 3500 A7 7500 1 1 X 2000 1 X 4000 1 X 6500 Working Voltage Freq...

Страница 3: ...gative battery cable before mounting your OKUR competition amplifiers or making any connections Check the battery and alternator ground connections Make sure they are properly connected and free of co...

Страница 4: ...TION Run a remote turn on cable from the headunit s remote swithed 12V output 3 4 SPEAKER CONNECTION DB Drive recommends to use minimum 12 gauge speaker connecting cables Run 12 gauge speaker connecti...

Страница 5: ...ng connection diagram cautiously to ensure the correct connection Step 1 Connect the master amplifier to the headunit and set its output master and input slave switch to output master position Step 2...

Страница 6: ...pli er to speaker cable on slave ampli er Remote turn on Ground MASTER AMPLIFIER SLAVE AMPLIFIER 8 2 ohms A7 3500H 1 A7 3500L 1 A7 7500 1 Ampli ers Linked minimum impedance is 2 ohms A7 3500L 1 workin...

Страница 7: ...r linked operation 3 If the OKUR competition amplifiers are shut down due to overheat Reset by turning off the remote input and allowing time to cool down Please make sure there are no airflow obstruc...

Страница 8: ...This limited warranty does not extend to units that have been subjected to misuse abuse neglect or accident Products that in DB DRIVE s judgment shows evidence of having been altered modi ed abused or...

Отзывы: