BER Pre/Post Viterbi
Pre and Post Viterbi alarms are set using the ranges provided in the drop down tabs. The
alarms are enabled by clicking the tick box.
BER is not recommended for monitoring the receiver, owing to the very sharp characteristic
of these measurements.
Tuner Temperature
This is the RF front end tuner temperature, which is approximately 25ºC higher than ambient.
Sets minimum and maximum Tuner Temperature, enter value and press
Set
. Tick box enables
alarm.
TS Bit Rate
Enter the appropriate lower rate into the box provided and click on Set.
Enter the appropriate upper rate into the box provided and click on Set.
TS O/P Select
Fixed as HP.
TS Sync (Always Enabled)
It is recommended that TS Sync is always enabled. Check this box to alarm on loss of incoming
transport stream.
Reset UCE
To reset the Uncorrected Reed - Solomon Errors click on the
Reset UCE
button.