DAX66 INSTALLATION — CONNECTING SOURCES 

Connecting Source Components to the DAX66

 

The DAX66 provides six source inputs that can be accessed by any zone. Inputs 1 ~ 4 are stereo, unbalanced, line level source inputs 

via RCA style female connectors. Input 5 provides a connection for a personal audio device or PC sound card via the 3.5mm stereo 

jack. Input 6 provides one S/PDIF input for a CD, DVD, cable, or satellite box via the Toslink jack, as well as a second 3.5mm jack.

 

The 3.5mm stereo jack on input 6 takes priority over the Toslink connector; do not connect cables to both the Toslink and 3.5mm jack 

the same time.  

Input 1 can be used as a paging or global; all-zones, input. When a source is connected to input 1 and 12Vdc is applied to the PA-IN 

jack (

tip positive

), source 1 will be broadcast to all zones. If there is no DC voltage is applied to the PA-IN jack, source 1 will operate 

like normal. 

 Infrared Emitter Outputs

 

The DAX66 has an IR repeater system built-in and each source has a corresponding Infrared (IR) emitter output. The IR emitter output 

is tied to the corresponding source device, or all (global) source control. Program a universal remote to operate all six of the input devices. 

Point the universal remote at the DAX66 keypad to transmit the IR control codes through the DAX66 to the source devices. With an IR

emitter connected to an IR

 

EMITTER output jack and the emitter placed over the source device IR receiver window, the source devices

can be controlled from any zone.

 

!

daytonaudio.com

[email protected]

S-VIDEO OUT

SATELLITE IN

VIDEO OUT

AUDIO OUT

HDMI

SATA

POWER

PHONE LINE

ETHERNET

DIGITAL

AUDIO OUT

COAX

(OPTICAL)

CD, DVD or Music Player 

Digital Optical

3.5mm

Stereo

RCA 

 

IR Emitter  

Содержание DAX66

Страница 1: ...6 SOURCE6 ZONE DISTRIBUTED AUDIO SYSTEM Model DAX66 UserManual...

Страница 2: ...nience receptacles and the point where they exit from the unit Only use attachments accessories specified by the manufacturer Unplug this unit during lightning storms or when unused for long periods o...

Страница 3: ...ith 4 8 ohm speakers in stereo mode 8 ohm speakers in bridged mono mode and provides a generous level of output power Please read and retain this manual to get the most from your Dayton Audio DAX66 6...

Страница 4: ...PANSION IN OUT Connect up to 3 systems MODE switch BRIDGE STEREO Four stereo RCA INPUTS 12Vdc PA trigger IN KEYPADS Input connects to keypad hub 12VDC TRIGGER OUTPUTS activate external devices AC Inpu...

Страница 5: ...keypad is designed for ease of use with a maximum ability to control sound Soft touch backlit buttons and a backlit LED display provide convenient control of the zone ON OFF source 1 6 selection volu...

Страница 6: ...o in the zone Once the MUTE function is activated the keypad s LED display will flash indicating the mute status Press the MUTE button to continue playing music or press the keypad volume up or down b...

Страница 7: ...ypads to the master controller amplifier we recommend Cat5e to connect keypads 5 The DAX66 uses a keypad hub all keypads will connect to the hub Install the keypad hub close to the master controller a...

Страница 8: ...inches Don t be concerned that too much insulation has been removed since the wire will be hidden in the wall behind the keypad Remove approximately 1 4 of insulation from the conductors and insert i...

Страница 9: ...r connect the Left Right channels of the amplifier together or combine the negative channels of the amplifier Improper speaker installation can damage the amplifiers and void the warranty If you are u...

Страница 10: ...peaker load of 8 ohms Remove approximately 5 inches from the cable jacket strip 1 4 of insulation from the speaker wire and twist the copper strands Insert the speaker wires into the connector per the...

Страница 11: ...or multiple zones The DAX66 can be used as the master controller in large commercial audio systems with constant voltage 25 70V amplifiers connected to the PRE AMP outputs The PRE AMP output levels ar...

Страница 12: ...ip positive source 1 will be broadcast to all zones If there is no DC voltage is applied to the PA IN jack source 1 will operate like normal Infrared Emitter Outputs The DAX66 has an IR repeater syste...

Страница 13: ...output that sends 12Vdc to the CONTROL OUT jack when any zone is powered ON and disconnects the 12Vdc when all zones are powered off DAX66 Trigger outputs ZONES 1 6 Zone ON 12Vdc applied to the TRIGG...

Страница 14: ...UT terminal of the bottom unit and the other end of the ribbon cable to the EXPANSION INPUT terminal of the second and then third unit Set the MASTER SLAVE 1 SLAVE 2 switch of the bottom unit to MASTE...

Страница 15: ...stands for control object code All All All Zone Zone Zone of of of Main Main Main unit unit unit 1 2 3 All All All Zone Zone Zone of of of Main Main Main unit unit unit 1 2 3 Zone1 Zone2 Zone3 of of...

Страница 16: ...Zone2 Zone3 Zone4 Zone5 Zone6 of of of of of of Main Main Main Main Main Main unit unit unit unit unit unit 1 1 1 1 Key in keypad Key in Key in 19200 Key in 38400 Key in 57600 Key in 115200 Key in 23...

Страница 17: ...eypad is turned 9600 CR change RS232 speed rate 19200 CR 38400 CR 57600 CR change change change RS232 RS232 RS232 speed speed speed rate rate rate to to to 19200 38400 57600 115200 230400 115200 CR ch...

Страница 18: ...n an RA Pack merchandise carefully to avoid further damage and complete the Return Form on the bottom of the invoice Record customer and RA numbers on the outside of the box Ship merchandise back to y...

Отзывы: