background image

 

NLC5.1ST User Manual 

7

Introduction

 

 
Broadcasters need a solution to effectively measure, and ultimately control the abrupt changes in 
loudness that sends viewers diving for their remote controls during commercial breaks and action 
scenes. The DaySequerra NLC5.1ST surround loudness control simultaneously measures the 
perceived loudness of 5.1 surround program audio along with 2.0 auxiliary stereo using the industry-
standard ITU-R BS.1770/1 loudness measure or the DTS-Neural Loudness Measure (NLM) algorithm.  
 
NLC5.1ST then uses the proprietary DTS-Neural Loudness Control, an advanced loudness leveling 
algorithm, to apply the appropriate gain or attenuation to maintain the broadcaster-defined loudness 
level. The resulting audio has a naturally open, dynamic quality without the annoying side-effects of 
traditional energy-based volume management solutions.  
 
Loudness is a perceptual property of an audio signal when it is reproduced acoustically. It is a complex 
non-linear function of amplitude, frequency and bandwidth. Current audio level meters measure the 
level of audio signals expressed as the amplitude of the signal - either the RMS (root mean square) 
voltage of an electrical signal or the sound pressure of an acoustical signal. Neither of these 
measurements, although widely accepted, provides accurate indications of how viewers will perceive 
the loudness of the audio programming.  
 
The DTS NLM algorithm uses a perceptual model of human hearing to more accurately detect spectral 
and density differences, inter-channel relationships and temporal overlaps in any audio content, 
resulting in a more accurate perceived loudness measurement over time. This proprietary algorithm 
was developed by after extensive research into human hearing and perceived loudness. 

 

 

To improve system reliability and up-time, NLC5.1ST uses a robust DSP-based processing platform 
rather than a PC-based approach to completely avoid broadcast disruptions caused by operating 
system lockups. An Ethernet interface provides long-term logging and field software updates capability. 
An optional factory-installed HD/SDI module will allow for measurement of 8 channels of program audio 
from group 1 or group 2 with user specified mappings within the group. A set of user-definable alarms 
can alert an operator of input loss, signal clipping and high or low signal levels referenced to the 
desired loudness level. 

 

 

When NLC5.1ST is used ahead of an AC3 (Dolby Digital) transmission, the target loudness level will 
also match the Dialnorm metadata information, thus providing consistent, enjoyable audio for all 
viewers.  
 
Whether pre-screening content at an ingest point or controlling the loudness of a broadcast air-chain, 
the DaySequerra NLC5.1ST is your key to reduce viewers complaints and improve audience 
satisfaction.  

Содержание NLC5.1ST

Страница 1: ...NLC5 1ST User Manual...

Страница 2: ...ce 1989 The technology developed for the NLC5 1ST and all of our products has evolved through a process of user feedback extensive listening field testing and careful refinement In the event that you...

Страница 3: ...os and trademark used herein are the property of their respective owners Specifications subject to change NLC5 1 User Manual Revision A 1 for firmware 4 01 01 NLC5 1ST Key Features Simultaneous 5 1 su...

Страница 4: ...vice Information The DaySequerra NLC5 1ST contains no user serviceable components inside the unit Please contact DaySequerra for repair and upgrade information In the event that your unit needs to be...

Страница 5: ...re DTS Neural Loudness Control Sample Rate 32kHz to 96kHz 24 bit Latency 1 4ms at 48k sampling rate 6ms for Hardware Interface GPIO Opto Isolated DB 9 female connector 0 5V TTL Ethernet 10 100 BASE T...

Страница 6: ...acturer could void the user s authority to operate this equipment The user should use only shielded and or grounded cables to combat sources of interference Environmental Preservation Efforts This equ...

Страница 7: ...vides accurate indications of how viewers will perceive the loudness of the audio programming The DTS NLM algorithm uses a perceptual model of human hearing to more accurately detect spectral and dens...

Страница 8: ...ing standard ITU R BS 1770 produces results known as LKFS that are referenced to a dB FS scale While certain Leq x measures match more closely to human loudness perception than traditional SPL or RMS...

Страница 9: ...th a single tone of a certain energy level and more tones are added with equal energy in the critical bands the total signal energy is kept constant regardless of the number of tones If changing from...

Страница 10: ...the HEIMDAL multi band model did not achieve the complexity of cochlear modeling as shown by J Allen the method had the lowest error compared to any preceding loudness models Nielsen Skovenborg 2004 D...

Страница 11: ...d two NEMA5 15P to IEC320 C13 AC power cables We strongly encourage you to save the shipping carton and shipping materials supplied with your NLC5 1ST They are specially designed to properly protect y...

Страница 12: ...dundancy connect each power supply to a separate UPS on different power circuits NLC5 1ST may be combined with other devices on the output of the UPS as long as the total load is within the UPS capaci...

Страница 13: ...the HOME screen HOME KEY A press of this button will return NLC5 1ST to the home screen or enter home screen selection mode BACK KEY This key will return to a previous menu or if you are entering a va...

Страница 14: ...y Open Upon an alarm condition this relay will close When the failure is remedied the relay will open Output 2 Relay 2 is Normally Open Upon a fault condition the relay will close When the failure is...

Страница 15: ...o standards such as NTSC 525 29 97 PAL 625 25 1080i 59 94 1080i 50 1080PsF 23 98 1080PsF24 720p 59 94 and 720p 50 The sample rate of extracted audio is converted to 48 kHz 24 bit resolution regardless...

Страница 16: ...value for the respective signal flow is displayed 3 The measured short term smoothed combined average of output audio is displayed in a large font rounded to the next whole number 4 Selecting the EDI...

Страница 17: ...ore attenuation is applied If an input signal falls between the Upper Thresh and the Lower Thresh in reference to the Target Level no correction will be applied For example A setting of 4dB indicates...

Страница 18: ...ow frequencies high or low frequency noise does not become over emphasized Compressor Threshold A compressor is present to catch any short term loudness peaks which aren t fully captured by the attack...

Страница 19: ...amic range Programming Menu To enter the programming menu press the ENTER key from the home screen while NLC5 1ST is unlocked The ENTER key will enter the selected sub menu or enter the value selectio...

Страница 20: ...m smoothed combined average of the 5 1 output 5 1 Out True Peak The measured instantaneous highest true peak value of the 5 1 signal output during the current measurement period 5 1 Out Correction The...

Страница 21: ...coder inputs To disable the keylock press ENTER followed by the BACK key Keylock Settings Keylock Settings sub menu will allow for configuration of the keylock timeout setting or disabling the automat...

Страница 22: ...performed for this signal flow Default In Line ST Output Mode Determines if the auxiliary stereo signal flow is subjected to loudness control When set to In Line loudness control processing is perfor...

Страница 23: ...defines what sample rate frequency NLC5 1ST will use 32 0 44 1 48 0 88 2 or 96 0 kHz Otherwise the detected sample rate recovered from the configured clock source is shown Audio Input Menu NOTE Unless...

Страница 24: ...e Name Allows you to change the name NLC5 1ST reports to DNS Press ENTER while the cursor is over this field to go into data entry mode Turn the rotary encoder to scroll through the available choices...

Страница 25: ...ify their functionality Default Off Meter Brightness Allows adjustment of the front panel LED bar graph meter brightness Default 0 Display Brightness Allows adjustment of NLC5 1ST display output brigh...

Страница 26: ...ls for each channel pair and the ALARM DELAY TIME which is defaulted to 5 sec Default Off for each channel pair AES Error When enabled NLC5 1ST will alert the operator on any AES errors Default Off Po...

Страница 27: ...has been encountered with the validity bit and audio output has been muted Check that there are no errors on the source equipment preventing it from passing valid audio data Bi phase Error A bi phase...

Страница 28: ...rra 1 Un Zip the files using a compatible utility that can handle ZIP archive file format into a new empty directory on your PC 2 Disable any additional network interface adapters present on your PC G...

Страница 29: ...tab 3 Enter the time server address to be used or use the public pool time nist gov 4 Press APPLY then UPDATE now to ensure the server address can be contacted A message will appear below the server a...

Страница 30: ...scope 2 Is there a software firewall running blocking access to the UDP port 44600 Make sure the port is open or the Remote Dashboard software is in your firewall s exclusion or white list Contact yo...

Страница 31: ...e customer accordingly DaySequerra reserves the right to replace any product that has been discontinued from its product line with a new product of comparable value and function This warranty shall be...

Страница 32: ...T User Manual Manufactured under license from DTS Licensing Limited DTS and the Symbol are registered trademarks and the DTS logo is a trademark of DTS Inc Product includes software DTS Inc All Rights...