7
Pump
Fittings
Hose
Use the 3/8-16 threaded holes in the base of the pump assembly for mounting.
When installing the pump on the coach the location should provide access to:
• Route the hydraulic hoses to the manifold.
•
Fill the reservoir and monitor the fill level.
• The cartridge valves and the end of the motor in case manual override of the system is required.
Install the hydraulic adaptor fittings in the top and bottom of each jack and install the fittings into
the manifold.
• The straight thread O-ring side always goes to the cylinder or manifold.
• The tapered side will get the hose attached to it.
•
When installing straight fittings into the leg or manifold, tighten to 15 lbs-ft. When using 90-degree
fittings, turn until finger tight, position correctly, then tighten the jam nut to 15 lbs-ft.
Install the hydraulic hoses
according to the chart.
• Route the hoses clear of all hot
exhaust components and pinch
points in the suspension/chassis
system. (moving objects, sharp
edges and high heat sources)
• Attach the hoses to the manifold
and jack fittings.
• Tighten to 15 lbs-ft. Secure the
hydraulic hoses with wire ties or
loom clamps to the chassis.
• Care should be taken to not kink
or twist hoses.
• The min. bend radius is 6 inches.
Installation of Hoses to the Manifold
Jack Leg
Left Front - Top
Left Front - Bottom
Right Front - Top
Right Front - Bottom
Left Rear - Top
Left Rear - Bottom
Right Rear - Top
Right Rear - Bottom
Manifold Connection
Brown Solid (T-1)
Brown Stripe (B-1)
White Solid (T-2)
White Stripe (B-2)
Orange Solid (T-3)
Orange Stripe (B-3)
Yellow Solid (T-4)
Yellow Stripe (B-4)
See drawings on next page.