Days EQUALIZER SYSTEMS EQ Smart-Level Скачать руководство пользователя страница 19

19

Operation

Auto Level Operation

Push and release the power button to engage power. The LED light next to the power button should be 

lit RED when power is on. You will need to have the ignition key in the off position to extend the jacks 

(most applications). If you attempt to manually extend jacks or all jacks with the Auto Level button, 
you will hear a deny tone from the keypad if the ignition key is in the on (engine run) position (most 
applications). Also depending on if the park brake disable is connected and the park brake is released 
you may not be able to extend jacks.
Press the Auto Level button and release. The system will send out a continuous series of beeps and 
the “Operating” LED will be on to let you know Auto Level is operation and will automatically level the 
coach. Do not move around or exit the coach during this operation, doing so will fault out the operation 
or result in an incomplete leveling/stabilization operation. When completed, the Keypad will signal 
the successful completion with a dual-stage tone. The Keypad may be left on once level has been 

achieved. The Keypad will enter “sleep mode” after five minutes of inactivity. 

Note: Auto Level will be denied if the jack indicator lights are on. To clear this press all, retract then 
perform Auto Level.

Setting the Null:  Null is the term used to indicate the levelness of the coach. A Null setting should have 
been performed by the installer. If the coach is not level following an attempt to Auto Level, you will 
need to level the coach and reset the null. To set the null, push and release the Power button on the 
Keypad to engage power. The LED light next to the Power button should be lit RED when the power is 
on. Level the coach by deploying jacks manually, or by simply parking the coach on a level site. You do 

not need to have the jacks deployed to set the null. Use a bubble level on a flat surface in the center 

of the coach as a reference. Once the coach is level, turn the power off at the panel. Depress and hold 

the Auto Level button and press and release the Power button and listen for a series of beeps. After the 
Keypad has beeped 5 to 6 times (the Keypad will continue to beep as long as the Auto Level button is 

held) release the Auto Level button you should get a confirmation beep. The new null has been set and 

the panel will store/remember this setting. Press and release the All Retract button to retract the jacks 
to the stowed position.

Use the All Retract button to retract the jacks prior to travel. This system does provide the ability to 
retract the jacks using the UP buttons for each pair of jacks. However, these buttons are not intended 
to be used for retracting the jacks to their stowed position prior to travel. The Up arrows are to be used 
only for retracting the jacks to help level the coach. The All Retract button must be pressed to ensure 
the system is ready/safe for travel. All jacks should automatically retract and return to stowed position 
when the ALL RETRACT button is pressed and released. The pump will run in retract for approximately 
5 seconds after the last jack has been fully retracted- or until a time limit of 90 seconds has been 
reached.  

*It is always the responsibility of the coach operator to visually

confirm that the jacks are fully retracted and safe for travel*

Содержание EQUALIZER SYSTEMS EQ Smart-Level

Страница 1: ...1 EQ Smart Level Motorized version Installation Operation Warranty Guide Effective April 2021 EQ021R3...

Страница 2: ...Pages 3 18 Jacks Page 4 Foot Installation For SL Jack Leg Assemblies Pages 5 6 Pump Fittings Hoses Pages 7 8 Wire Harness Install Control Panel Pump Pages 9 11 14 Chassis Interface Connection Page 10...

Страница 3: ...secure harness and hydraulic hoses to the coach Self drilling screws or pop rivets or other to secure harness and hoses Wire ties 10 16 quarts could be more depending on system Automatic Transmission...

Страница 4: ...eration of the system For some they can be directly bolted to the existing mounting brackets or structure For some the brackets may need to be welded to the frame to which the jacks can be bolted For...

Страница 5: ...straight and is not cross threaded 5 Using the 1 2 Allen drive bit and 1 2 impact wrench gun tighten the bolt into the rod Allow the impact wrench to impact drive the bolt totally to full depth Note t...

Страница 6: ...y install or tighten at this time Remove the nut 2 Position the hole in the middle of the foot pad over the threaded end of the rod Start the nylock nut onto the threads by hand 3 Using the impact wre...

Страница 7: ...90 degree fittings turn until finger tight position correctly then tighten the jam nut to 15 lbs ft Install the hydraulic hoses according to the chart Route the hoses clear of all hot exhaust componen...

Страница 8: ...8 Hose connections...

Страница 9: ...ucture The control panel is not waterproof therefore it must be in an interior location or compartment protected from the elements and spill areas Attach the supplied wire harness between the Control...

Страница 10: ...the wire hot and will prevent jack extension when the vehicle ignition key is in the on engine run position This also provides for a jacks down warning in the event of a jack drifting from the stowed...

Страница 11: ...n may be fused at the source with a 150 amp circuit breaker This 12v supply must be a dedicated and isolated circuit not shared with other devices and must be constant non switched 12vdc Attach a 4 ga...

Страница 12: ...ing them together and one of them will have a small gauge fused yellow wire This battery connection may be fused at the source with a 150 amp circuit breaker This 12v supply must be a dedicated and is...

Страница 13: ...tible to corrosion The battery must be connected to the frame with 4 gauge or larger wire It is not acceptable to allow the pump mounting bolts to be the sole grounding connection Attach a 4 gauge wir...

Страница 14: ...should be a minimum 100 RC Reserve capacity with a 500 CCA Cold Cranking Amperage The higher these numbers the better Common types are flooded lead acid Gel and AGM Absorbed Glass Mat Note Some lithi...

Страница 15: ...Recheck the reservoir and fill to full Note the fluid level in the reservoir is at maximum when all jacks are fully retracted and minimum when jacks are fully extended This full extension and retracti...

Страница 16: ...1 2 full Do not allow the reservoir to run empty If jacks s will not fully extend crack loose the upper hose s at the jack s and run the pump to extend until air is expelled Use Caution hydraulic flui...

Страница 17: ...ol panel is replaced or moved to a different location With the control panel off press and hold the ALL RETRACT button then while holding it press the POWER button then release both buttons The power...

Страница 18: ...ress the POWER button on the keypad to activate the unit The LED light next to the Power button should be lit RED when the power is on Level the coach by deploying jacks manually or by simply parking...

Страница 19: ...push and release the Power button on the Keypad to engage power The LED light next to the Power button should be lit RED when the power is on Level the coach by deploying jacks manually or by simply...

Страница 20: ...5 Using the Down Keypad buttons extend the jacks until they contact the ground this is referred to as planting the jacks As you extend the jacks an LED light on the Keypad will indicate the jack s is...

Страница 21: ...lity your Bluetooth connectivity may be through your multiplex system The operation of the system from a smart phone is the same as from the control panel with the exception that you cannot perform th...

Страница 22: ...ED ON Red when ignition is in the ON position OFF when iginition is off Excess Slope LED ON Red following an Auto Level attempt if system cannot overcome slope OFF when slope is not excessive If the L...

Страница 23: ...uld be taken that no one or objects could be harmed by this occurrence The collapse of the jacks will lower the vehicle This collapse is controlled not rapid by the system circuit design components an...

Страница 24: ...down from their retracted stowed position For cartridge valves rotate the center screw fully counter clockwise For directional valves rotate the red knob until it snaps back to the normal position or...

Страница 25: ...ge valves are clustered together on the side of the pump manifold They are labeled 1 thru 4 Locate the screws on the appropriate cartridge valve s Using a 1 8 Allen wrench turn the screw s clockwise u...

Страница 26: ...26...

Страница 27: ...t listed on this guideline will require prior authorization from an Equalizer Systems representative A reasonable time allowance will be determined by the Equalizer Systems representative Any warranty...

Страница 28: ...purchase date are required No additional warranties expressed or implied are authorized by Equalizer Systems This warranty voids all previous issues Questions concerning this warranty should be direct...

Отзывы: