Code Description
Possible Reason
Counter Measures
Warning
Code
Phase loss
protection
3 phase AC power supply
phase lost
Inspect AC power supply cable
connections
Lose phs
6
28
Code Description
Possible Reason
Counter Measures
Abnormal
Code
Abnormal Tank/Well
water level
Wait for the water level to return to
normal, system will begin countdown to
restart
Tank/
Well
Change the water level switch or check
wiring
5.4 Fault Inquiry and Reset
The Sunverter records the fault codes of the latest 4 events. Searching this information
will help find the fault cause. Fault information is stored in the control parameters
Pr.20~Pr.23 refer to the panel operation instructions to view the fault codes and find
solutions.
When a fault occurs and the inverter needs reset to return to normal, press and
keys simultaneously. Alternatively, switch off power and reset.
CAUTION
Be sure to check the cause of fault and eliminate it before
resetting. Continuous resetting of the inverter is harmful to
the controller.
CAUTION
Allow delay of 5 minutes before reset for overload and
overheat protection
Correctly install and set the parameters
according to manual
Water level abnormal
Wrong installation
Water level switch damaged
or wiring damaged
Parameters setting for
the water level switches