background image

POOLCHLOR 

SALT WATER CHLORINATORS

Installation & 

Operating Manual

Содержание Poolchlo30

Страница 1: ...POOLCHLOR SALT WATER CHLORINATORS Installation Operating Manual ...

Страница 2: ......

Страница 3: ...ICATIONS 1 1 2 OPERATING PRINCIPLES 3 INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted 3 WATER CHEMISTRY 3 4 EQUIPMENT CELL INSTALLTION 5 5 EQUIPMENT OPERATION 11 6 MAINTENANCE 14 7 TROUBLE SHOOTING 17 ...

Страница 4: ...on and forget about pool chlorination Free Chlorine No more chlorine bills the unit will pay for itself in about a year Improved swimming pleasure Saltwater chlorinated water puts an end to sore red eyes and smelly itchy skin Dayliff PoolChlor is a high performance high specification unit that includes the controller a separate long life electrolysis cell and a flow sensor Congratulations on selec...

Страница 5: ...tively for a 100m pool The PoolChlor should be pro rated for other pools size up to a maximum 3 recommended capacity of 150m in low bathing load and lower temperature applications pool pump operating petriod being set to give the required daily chlorine dosage levels For optimal water quality a variable speed pool pump is recommended that can be set to run continuously at low speed at reduced chlo...

Страница 6: ...n purposes Flow Switch This component detects the water flow in the pipe and protects the system WATER CHEMISTRY As with any pool it is important that proper water chemistry of the pool water is maintained including pH alkaline content and calcium levels The only special requirement for the poolchlor is to maintain proper levels of salt and stabilizer It is important to maintain these levels in or...

Страница 7: ...ompressed pellets Ensure good salt quality 99 pure NaCl may be used Avoid using salt with anti caking agents Sodium Ferrocyanide also known as YPS or Yellow Prussiate of Soda that could cause discoloration of fittings and surface finishes in pool Do not use Calcium Chloride as a source of salt Do not use Rock Salt insoluble impurities mixed with the rock salt can shorten the life of the unit Salt ...

Страница 8: ...320 168 224 280 144 192 240 120 160 200 96 128 160 72 96 120 48 64 80 OK OK OK Ideal Ideal Ideal OK OK OK High High High Dilute Dilute Dilute 200 600 1000 1400 1800 2200 2600 3000 3400 3800 4200 4400 3 40m 128 112 96 80 64 48 32 OK Ideal OK High Dilute 4 EQUIPMENT CELL INSTALLATION The following are basic plumbing instructions for a typical installation which entail positioning the Flow Switch and...

Страница 9: ...ontally ensure that the wire side faces upwards The Flow Switch is approximately 100mm in length a typical gap required is 30mm Ÿ When positioning the Cell consider the side of the cell with the cord as the inlet side If installed horizontally ensure that the wire side faces upwards From end to end the Cell with both unions is approximately 40cms length a typical gap required is 35cms To ensure pr...

Страница 10: ...ertight seal do not over tighten the collars and only tighten them by hand When using a Variable Speed Pump on a low speed setting the cell should be inverted in order to ensure adequate flow efficient chlorine production as shown in Fig 3 below Flow Switch Cell After determining the section of plumbing to install the Flow Switch and Cell measure out and mark the selected area 1 To install the Flo...

Страница 11: ...ed spaces to avoid a build up of excess heat For operation the control unit may be wired in to the pump s power source so that both turn on and off together or energized continuously for use with variable speed pumps Flow switch will control Cell power but lights will remain on Wiring Power must be shut off at the circuit breaker before performing any wiring Be sure to follow local and electrical ...

Страница 12: ...r Off mode until enough salt has been added to the water VOLTAGE CONVERSION Always double check the voltage of the power source Connection to improper voltage can a cause severe damage harm or b cause lights and screen to power on without system function All service should only be done by a person with appropriate electrical skills with all equipment disconnected from power The unit is shipped fro...

Страница 13: ... switches ON and OFF concurrently with filter pump or is energized continuously for use with variable speed pump Checked all connections and joints for leaks Sufficient salt has been added and fully dissolved and circulated throughout the pool water Pool has properly balanced water chemistry Initial Start Up Switch on the pool pump or timer controls This should activate the system and within momen...

Страница 14: ...3 Water chemistry balance including the amount of salt in the pool and chemicals that minimize chlorine demand such as stabilizer level in the water See Water chemistry information on page 3 After making the initial adjustments to the Chlorine Output level additional adjustments are only necessary due to changing seasonal temperatures or changes in bather load Ensure that the pump runs long enough...

Страница 15: ...on 6 Menu Press sequentially to cycle through the following information 1 Pool Temperature in degrees celsius 2 Cell Voltage in many cases 21 0 to 27 0 when chlorine is being generated otherwise 16 31V 3 Cell Current in many cases 2 50 to 7 80A when chlorine is being generated otherwise 0A during normal rest cycles 4 Real Time Salinity reading xxxx ppm or x x grams Liter 5 System ID 6 Software rev...

Страница 16: ...st be raised before operation is restored See Adding Salt for more information Ÿ Hi Salt When this LED is flashing the salt level is higher than necessary When this LED is illuminated steadily the salt level is too high and the Cell has shut down The pool water must be diluted with fresh water before operation is restored Ÿ Check Cell When this LED is illuminated Cell efficiency is greatly reduced...

Страница 17: ...gh cleaning it may require additional cleaning or the cell may be at the end of its life cycle and may require replacement Maintaining the Electrolytic Cell As a natural result of the electrolytic process which creates chlorine from salt molecules a white mineral build up is attracted to the titanium plates in the Cell The self cleaning feature helps to inhibit such build up and scaling However th...

Страница 18: ...ve cleaning will reduce lifespan of the cell If submerging entire Cell assembly do not allow Cell cable to be covered by liquid CAUTION When cleaning the Cell always wear adequate protection such as rubber gloves and eye protection Always add acid to water do not add water to acid Always work in a well ventilated area Splashing or spilling acid can cause severe injury and or property damage CAUTIO...

Страница 19: ...n a safe place Ÿ Increase Chlorine Production when temperature increases Ÿ Increase Chlorine Production when number of bathers increases Ÿ Use Stabilizer to prevent chlorine dissipation by the sun Ÿ Mount Control Unit in shade or out of the direct sunlight whenever possible Ÿ Decrease Chlorine Production when temperature decreases Ÿ Take pool water sample to a Pool Professional at least once per m...

Страница 20: ...bottom of the control unit and that the wire is not cut or damaged Make sure there is at least 30cms of straight pipe before the flow switch If there is adequate flow and the LED is still on check that the arrows on the flow switch are pointing in the direction of flow If the light is flashing the flow is established and t h e c h l o r i n a t o r w i l l t u r n o n w i t h i n 1 m i n u t e No ...

Страница 21: ...ed but the pool water is unable to hold on to the chlorine due to low stabilizer Filter pump switched off or filter pump time too short 8 hours for average size pools more for large pools Salt level too low below 2500 ppm Low Salt LED on Add salt atleast 3000ppm Salt level too high high Salt LED on Dilute pool water with fresh water and check salt level is 3000ppm Low pH Low pH oxidizes chlorine q...

Страница 22: ...y shock the pool if indicated in the directions on the algae treatment It still may be a matter of days before the pool returns to normal and chlorine tests will show the desired 1 3ppm free chlorine reading PCB displayed and all 4 LEDs are illuminated A possible printed circuit board fault has been detected Refer to authorised service provider ...

Страница 23: ...any warranty condition or liability implied by law the liability of Davis Shirtliff hereafter called the Company in respect of any defect or failure of equipment supplied is limited to making good by replacement or repair at the Company s discretion defects which under proper use appear therein and arise solely from faulty design materials or workmanship within a specified period This period comme...

Страница 24: ...INS393A 03 18 www davisandshirtliff com ...