background image

5

5.  TROUBLE SHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

Rotating the wrong way

Low rotating speed

The pump 
does not 
pump 

Change connections of electric 
motor

Pump not primed

Foot valve leaking. Leaks in gaskets 
or suction piping. Check and repair

Check the reason for this low speed 
(excessive  consumption  or  low 
frequency)

Suction head too high

Take  the  pump  closer  to  the  water 
level. Change the pump for another 
with less NPHSr. Reduce leaks in the 
suction piping

Air getting into suction pipe

Test  pressure  the  suction  pipeline 
including the pump and observe any 
liquid leak

Insufficient liquid intake

E x t e n d   t h e   s u c t i o n   p i p e l i n e 
increasing the submergence

Foot valve partially blocked

Insufficient 
flow

Clean footvalve

Insufficient liquid intake

Submerge  the  foot  valve  more/ 
Reduce the flow

Air pockets in suction line

Change  the  arrangement  of  the 
pipeline. 

Direction changed

Change  connections  of  electric 
motor

Internal parts worn

Replace the worn parts

Содержание DFP

Страница 1: ...DFP Sanitary Pump Installation Operating Manual...

Страница 2: ......

Страница 3: ...SPECIFICATIONS 1 1 2 INSTALLATION 2 ELECTRICAL CONNECTIONS 3 3 OPERATION 4 4 TROUBLE SHOOTING 5 5 INDEX Davis Shirtliff Ltd 2023 Contents herein are not warranted TERMS OF WARRANTY 6 7...

Страница 4: ...ater treating systems pharmaceutical food and refining chemical industries The design features optimised hydraulics for high efficiency and polished internal finishes to prevent fouling by bacteria an...

Страница 5: ...ight The diameter must be 1 5 to 2 times the diameter of the pump s suction flange The inlet cone must be eccentric when the pump works under depression If it works under load this cone may be concent...

Страница 6: ...n negative suction it should have a suitable foot valve placed at required depth to prevent air intake The delivery piping must Be properly sealed Have proper dimensions to avoid excessive head losses...

Страница 7: ...s the fluid should overflow the system to ensure that all the air has been vented Make sure that the direction of rotation coincides with the direction of the arrow located on the pump body Centrifuga...

Страница 8: ...el Change the pump for another with less NPHSr Reduce leaks in the suction piping Air getting into suction pipe Test pressure the suction pipeline including the pump and observe any liquid leak Insuff...

Страница 9: ...nsumption Test pressure the suction pipeline including the pump and observe any liquid leak Air trapped in the suction line The pump vibrates Change the impeller clean the impeller Impeller imbalanced...

Страница 10: ...f careless handling lack of maintenance faulty installation incompetence on the part of the equipment user Acts of God or any other cause beyond the Distributors reasonable control Also any repair or...

Страница 11: ......

Страница 12: ...INS528A 03 23...