background image

AQUASTRONG SMART 45

Water Boosting Pump

Installation & 

Operating Manual

Содержание AQUASTRONG SMART 45

Страница 1: ...AQUASTRONG SMART 45 Water Boosting Pump Installation Operating Manual ...

Страница 2: ...Location 4 3 4 Piping Connection 5 3 5 Mains Water Pressure Boosting 6 3 6 Suction from a Well 6 3 7 Suction from fresh Water Tank 6 4 OPERATION 7 7 TERMS OF WARRANTY 12 4 2 Starting the Pump 7 4 3 Setting the Correct Pressure 7 4 1 Priming the Pump 7 4 4 Control Panel 8 5 TROUBLE SHOOTING 10 6 MAINTENANCE AND STORAGE 11 2 WARNINGS AND SYMBOLS 3 ...

Страница 3: ...queries they should be referred to the equipment supplier Set Pressure Operating Pressure Permanent Magnet Motor High Efficiency Variable Speed Pressure Constant Hot Water 0 Handling to 80 C Eco friendly Low Noise 60dB Warning Indicator Lights 3 FLOW RATE m hr 1 2 3 4 5 5 10 15 20 55 45 40 50 PUMP FULL SPEED 4 5 BAR 3 FLOW RATE m hr 1 2 3 4 5 5 55 2500RPM 10 15 20 25 35 45 40 30 50 3000RPM 3500RPM...

Страница 4: ...option of adjustable constant pressure settings that matches flow with demand and constant speed function that varies pressure with demand Easy to use LED control panel with display for operating mode motor speed operating pressure and various fault indicators Convenience features including adjustable inlet and outlet connectors for installation flexibility inbuilt non return valve and integral ma...

Страница 5: ... Ensure no water leakage onto the pump motor or its electrical connections during installations venting or operations as this may cause electrical shocks Non approved replacement parts may not be used Any action that doesn t comply with safety warning sign may cause personal injury pump damage and losses in property Users must also comply with the local safety regulations WARNING WARNING WARNING W...

Страница 6: ...n from cold surfaces 3 2 Minimum Space The pump requires a minimum space of 620x400x530mm Even though the pump does not require much space it is recommended that there is enough room for service and maintenance access 3 3 System Sizing The pump is factory set with 3bar outlet pressure which can be adjusted according to demand The tank pre charge pressure is 1 25bar In case of suction lift of more ...

Страница 7: ...NG 1 Turn the union nuts by hand to loosen the inlet and outlet ports 2 Seal the pipe fittings using thread tape 3 Carefully screw the inlet and outlet connections onto the pipe fittings using a pipe wrench or similar tool Keep the union nut on the pipe fitting if it has been removed from the pump 4 Fasten the connections to the inlet and outlet Hold the connection with one hand and tighten the un...

Страница 8: ...oot Valve with Strainer 5 Drip Tray Install the pump on a small stand to prevent the ventilation holes from being ooded NOTE 1 2 3 4 H1 H2 4 3 2 1 3 6 Suction from a Well 3 7 Suction from Water Tank Maximum suction lift is 8m For well applications inlet pipe must be submersed atleast 0 5m NOTE ...

Страница 9: ... required pressure by adjusting the buttons on the control panel 6 Close the tap 7 The pump is ready for use 4 3 Setting the correct pressure The pump can be set between 1 0 to 5 5bar at intervals of 0 5bar The factory setting is 3bar The default pressure of 3 0 bar will suit most applications The difference between the inlet and outlet pressure must not exceed 3 5bar Example If the inlet pressure...

Страница 10: ...re settings of 4 5 5 0 and 5 5bar require a positive inlet pressure and the settings must only be used when boosting from the water mains WARNING 4 4 Control Panel Press switch button to start the pump press the switch button again to switch it off The pump can be changed automatically from Auto mode to forced start mode by pressing down the switch button for 8 seconds up switch _ down ...

Страница 11: ...reset the pump Set Pressure Operating Pressure Warning Indicator Lights Faulty LED Indicator Guidelines Setting pressure Operating pressure _ up switch down M SMART45 1 Power supply failure 3 The pump is blocked Switch on the power supply Check the cables and cable connection for defects loose connections or for blown fuses in the electrical installation Check whether there is any leakage in the p...

Страница 12: ...eplace sensor and fit tightly back in the pump Restart the pump the indicator will then go off 5 TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Pump does not run No power Motor overheating due to i Liquid temperature being too high ii Blocking by foreign bodies Eliminate the cause of overheating Residual current circuit breaker triggered Reset circuit breaker Replace motor Motor defective Pump r...

Страница 13: ...ith correct installation and operation Smart 45 does not need regular maintenance During periods of inactivity the pump must be disconnected from the power supply and placed in a dry location Proceed as follows 1 Switch off the pump using on off button 2 Disconnect from the power supply 3 Open a tap to release pressure in the pipe system 4 Close the isolating valves and drain the pipes 5 Gradually...

Страница 14: ...y condition or liability implied by law the liability of Dayliff hereafter called the Distributor in respect of any defect or failure of equipment supplied is limited to making good by replacement or repair at the Distributor s discretion defects which under proper use appear therein and arise solely from faulty design materials or workmanship within a specified period This period commences immedi...

Страница 15: ......

Страница 16: ...INS481A 03 21 ...

Отзывы: