Gas Valve
Connection Requirements
»
Installation of valve block should be done by Daygas Authorized Service.
»
Before connecting the valve block to the gas pipeline, the gas pipeline must be
cleaned and degassed.
»
Gas valve and natural gas line connection must be made with G3/4” flex.
»
The gas flow direction must match the arrow on the lower surface of the valve
block.
»
Gaz akış yönü, valf bloğunun alt yüzeyinde bulunan ok ile eşleşmelidir.
»
When connecting the gas valve, dust, dirt, liquid drugs used in the connection
materials, etc. materials should not be missed.
Gas Valve
Setting Procedure
»
Turn on the gas supply and power supply to the device.
»
Make sure that the inlet pressure of the gas valve is at least 21 mbar.
»
Loosen the screw at the gas outlet pressure measurement point on the gas
valve of the device.
»
Connect the manometer to the nipple using a rubber or PVC pipe.
»
Measure the gas outlet pressure of the valve block.
»
The pressure setting of the 1st stage is increased by turning it clockwise with
a Phillips screwdriver from the point shown in Figure 1, and the pressure is
decreased by turning it counterclockwise.
»
The pressure setting of the largest step is increased by turning it clockwise
with the ten socket wrench from the point shown in Figure 1, and it is decreased
by turning it counterclockwise.
»
By slowly turning the screw of the adjustment pressure regulator to the
right and left, the burner nozzle make sure that the gas pressure at the inlet
changes.
»
The pressure setting of the device is adjusted according to the data on the
information label.
»
After the gas pressure adjustment is made, disconnect the manometer from
the nipple.
»
Be sure to tighten the screw inside the nipple well.
»
After tightening the screw, check its tightness with a soapy solution.