Safety Rules

CAUTION! Carefully read the warnings and information contained in this manual.

Local gas distribution companies approved by the manufacturer and having the 

installation qualification approved by the local gas distribution companies of these 

companies. Assembly by the manufacturer’s authorized persons who have 

received assembly training. Must be installed in accordance with the rules.

Make sure that the areas where the device will be installed are adequately 

ventilated. Should be done. In accordance with the ventilation conditions 

determined by the local gas distribution companies should be mounted. 

The device should never be operated in areas without adequate ventilation.

The device, which is not properly assembled, should never be operated.

Gas determined by local gas distribution companies in the usage area of the 

device it must be checked whether it is suitable for the usage pressure. It should 

be used by making the necessary settings.

The device should never be operated without providing the necessary settings.

In the region where the device will be installed, the electricity distribution 

company has determined.Whether the electric current and the required electric 

current for the device to work are suitable must be checked.

In cases where it is not suitable, the device should never be operated.

Check whether the electric current is consistent in the area where the device will 

be installed. Should be done. If necessary, the electric current should be made 

consistent by using additional devices.

The device should never be operated before the electric current becomes consistent.

In the area where the device will be installed, the grounding line in the electrical 

connection suitability should be checked. Grounding line in areas where it is not 

suitable must be taken separately.

The device should never be operated in areas where the grounding line is not properly connected to the 

device.

5

www.daygas.eu

Содержание LODOS Series

Страница 1: ...S GAS UNIT HEATER USER MANUAL AND WARRANTY CERTIFICATE MANUFACTURER Daygas Heating Systems n Tah Ltd Sti Firuzk y Bulvar No 206 34325 Avcilar Istanbul 0 850 532 91 53 0 212 423 30 44 Avcilar VD 271079...

Страница 2: ...on and Operation of Lodos Series Commissioning Procedure Technical Maintenance 3 4 5 6 7 8 9 10 16 16 17 18 Lodos Series Purpose Usage Areas 15 Prosestat Axial Fan Axial Fan Technical Specifications C...

Страница 3: ...Our company has been operating since 2014 and has been operating in production sale and aftersales activities of ceramic fillet heaters industrial ceramic fillet heaters hot air generators pipetype f...

Страница 4: ...and sites Buildings structures and soil in the process of construction of buildings and structures For technological heating of materials and equipment Lodos gas unit heater series heating systems can...

Страница 5: ...r it is suitable for the usage pressure It should be used by making the necessary settings The device should never be operated without providing the necessary settings In the region where the device w...

Страница 6: ...specifications of LODOS are on page 14 the technical specifications of the ignition electrode are given on page 7 Gas Valve Technical Specifications PARAMETER VALUE Maximum connection pressure Pa mbar...

Страница 7: ...requency of the connected valve block Hz Waiting time for the ignition system Second Response time of the flame control system Second Distance between spark plug electrodes mm Precision of combustion...

Страница 8: ...of 350 mm 500 mm 700 mm fans to heat the heat generated inside the boiler When the ambient air is rotated 2 3 times the heat ing process takes place The waste gas formed is thrown out with the help of...

Страница 9: ...the device Connect the manometer to the nipple using a rubber or PVC pipe Measure the gas outlet pressure of the valve block The pressure setting of the 1st stage is increased by turning it clockwise...

Страница 10: ...gh voltage spark plug combined with a flame sensor ionization sensor in a housing The ignition block has a plate in the holes to which two ceramic insulators are fixed A high voltage spark plug electr...

Страница 11: ...n the air processor malfunctions this warning code or warning light appears on the screen of the devices When the air temperature is broken the devices do not work Axial Fan Body and propeller blades...

Страница 12: ...ng conditions The fan produced from forward curved galvanized steel sheet with thin strength blades provides optimum performance with high pressure air flow and low noise level E2 fault warning code a...

Страница 13: ...ource Frequency Input power Transfer Flow Pressure Noise level Min Max ambient temperature Weight Body Fan Protection class Motor insulation class 230 V 50 Hz 44 W 1850 rpm 170 m h 410 Pa 38 dB 30 180...

Страница 14: ...180 360 450 540 50 3300 Lodos 30 30 2 85 2 11 660 660 820 49 54 152 190 228 456 570 684 55 3500 Lodos 35 35 3 33 2 46 660 660 820 49 54 176 220 264 528 660 792 55 3500 Lodos 40 40 3 80 2 81 660 660 82...

Страница 15: ...left and top of the device shown in the figure If the device is to be mounted above the ground if you use a foot other than the Daygas Lodos mounting foot shown in figure 1 make sure that the foot you...

Страница 16: ...ure that there is grounding in the electrical installation Grounding is required Commissioning Procedure CAUTION The person who activates the Lodos heater Read this guide The person who commissions th...

Страница 17: ...be closed while testing the strength tightness and control pressure of the gas pipeline otherwise this may damage the valve block Check the gas pressure in front of the heater The gas pressure must co...

Страница 18: ...operation of the heater Clean the outer surfaces from dust and dirt wipe the reflective surfaces of the reflectors with a dry and soft cloth Clean the inside of the heater by blowing compressed air at...

Страница 19: ...g is prohibited Gas and Electricity Connetion Considerations Gas Connection The gas connection of the device has been authorized by the distribution company and must be done by certified persons The g...

Страница 20: ...t on the information screen on the device does not turn on Check the electrical connection of your device My device ignites but does not catch fire Check the gas connection of your device My device do...

Страница 21: ...contact with the device Check the gas connection of your device against gas leakage Do not interfere with your device with bare hands Make sure that the flammable part of your device is flammable and...

Страница 22: ...22 WARRANTY CERTIFICATE...

Страница 23: ...repair The consumer may request the return of the goods a reduction in the price at the rate of defects or if possible the replacement of the goods with a non defective one from the seller The seller...

Страница 24: ...ce heating 5 In case the device s are first started up outside of Daygas Heating Systems or Daygas authorized service 6 In case of malfunctions and damages arising from electrical voltage fluctuations...

Страница 25: ...25...

Страница 26: ...Brand Model Serial Number Authorized Service Title Address Phone Number Fax E Mail Authorized Stamp Yetkili Signature Seller Company MANUFACTURER Title Address Phone Number Fax E Mail Authorized Stamp...

Страница 27: ...sioning Date Of The Product MANUFACTURER Daygas Heating Systems n Tah Ltd Sti Firuzk y Bulvar No 206 34325 Avcilar Istanbul 90 850 532 91 53 90 212 423 30 44 Avcilar VD 2710796836 Title Address Phone...

Страница 28: ...325 Avcilar Istanbul 90 850 532 91 53 90 212 423 30 44 info daygas eu www daygas eu MANUFACTURER Daygas Heating Systems n Tah Ltd Sti Firuzk y Bulvar No 206 34325 Avcilar Istanbul 0 850 532 91 53 0 21...

Отзывы: