Thanks to its feature of digital constant water setting, the water
temperature will remain constant in the degree you set.
The fuel efficiency is reduced in low water temperature as your
device can operate in the desired constant water temperatures.
By the automatic water controlled on/off system, when the water
valve is opened, the water heater will be ignite automatically and the
hot water flow will be provided. When the water valve is closed, the
water flow will stop and the flame will be off automatically.
Thanks to its feature of operating with low pressure water, it will not
be affected by the low water pressure that occurs in the high
apartment flats. 2 mSS
The temperature control adjustment buttons make for users easy to
obtain different water temperature that they desire.
By the high pressure safety system, when the water pressure is
higher than it’s needed, safety valve will discharge the excess water
by become a part of a activity.
By the high temperature safety system, in case of the water getting
hotter than it is needed, the gas will be cut off automatically and the
damage of the water heater will be prevented.
The flame instability is prevented and the water is cooled after the
flame is off with the features of blowing inside the water heater before
the ignition (air fan blows air for 2~4 seconds before ignition) and the
blowing after service (air fan will go on blowing air for 10 seconds
after the water stops and the flame is off).
Thanks to the safe and reliable design of the combustion system, the
air is taken from outside by the fan for the purpose of the combustion
and it is sent out again after the combustion.
By the system of continuous electronic ignition, 100% success is
achieved in ignition.
The device is equipped with the multi-purpose safety system. Even if
the power is supplied to the water heater again in power failure, fan
failure, the blocking of the waste gas pipe or strong reverse wind
blowing the gas will be automatically cut and the automatic ignition
system will be disabled. In this case the water heater will need to be
restarted.
1. THE FEATURES AND THE CHARACTERISTICS OF
YOUR WATER HEATER