DAXOM UKDAX-11ST Скачать руководство пользователя страница 11

 

 

The  fault  code  may  occur  on  the  Lcd  display  when  the  device  does 

not  operate  and  the  device  may  give  an  audio  warning.  The 

meanings of these codes are: 

Fault codes 

FAILURE DESCRIPTION 

E0 

Water Inlet Sensor Failure 

E1 

No ignition 

E4 

Fan Failure 

E6 

NTC Failure 

 

 

 

 

 

 

 

 

 

 

 

 

 

When the 

 button is pressed the temperature you want to set will 

increase  and  when  the 

  button  is  pressed  the  temperature  you 

want to set will decrease.  

Your water heater has the capacity to heat 11 lt of water per minute. 

If you would like to obtain high temperature from the water heater in 

winter months (like 65 C) please set the adjustment valve in the cold 

water inlet to minimum position.  

Please  check  the  temperature  of  the  water  with  your  hand  before 

aiming it to your body against any burning event. 

 

 

  

 

5.1.1.Water And Temperature Kontrol 

Содержание UKDAX-11ST

Страница 1: ......

Страница 2: ...o not attempt to operate the device by yourself In case of you use LPG gas do not mount your water heater in places below the ground level Check whether your water heater conforms to the gas type you...

Страница 3: ...e safety system in case of the water getting hotter than it is needed the gas will be cut off automatically and the damage of the water heater will be prevented The flame instability is prevented and...

Страница 4: ...l be provided When the water valve is closed the water flow will stop and the flame will be off automatically Thanks to its feature of operating with low pressure water it will not be affected by the...

Страница 5: ...atural Gas G20 Gas input pressure 30mBar 20mBar Fan Power 36 W Water flow t 25K 11 l min 11 l min Nominal power P 19 15 KW Nominal load Q 22 8KW Gas consumption 2 12 kg h 2 12 kg h Water pressure Min...

Страница 6: ...during the repair and maintenance there should be sufficient space around the device for repair and maintenance Flammable and explosive substances must definitely be kept away from the water heater Th...

Страница 7: ...waste gas pipe hole according to pipe measurement which is given as follows The waste gas pipes are supplied with the water heater Place the fresh air waste gas pipe into the holes previously opened...

Страница 8: ...ges of the bracket part as to face the water heater chimney and the pipe Fill hole opened for the waste gas pipe in the wall with a substance resistant to burning and isolate it Make sure that the iso...

Страница 9: ...water leakage There should be a valve in the cold water main pipe line in order to cut the water when needed Connect the hot water flow of the water heater to the hot water pipe of your installation w...

Страница 10: ...o C and 65 o C degrees The water temperature you set will show stability after some time according to the distance of the water heater to the tap and the change of the water pressure Turn on the wate...

Страница 11: ...re you want to set will increase and when the button is pressed the temperature you want to set will decrease Your water heater has the capacity to heat 11 lt of water per minute If you would like to...

Страница 12: ...hen pres SET button to enter injection water rate setting mode Press 12 indicates setting water injection rate is 120 L Shut the gas and water off after using and then in order to shut the water heate...

Страница 13: ...nplug anything before the gas leaves out completely Do not forget that any flame or a spark that may occur in such a case will lead to fire or explosion Check the pipes mount the places where happens...

Страница 14: ...ou must not disconnect electrical connection and ON OFF buttons on the heater pannel must be ON position At that position your heater will be heat inside water by automatically short time working and...

Страница 15: ...ain E3 Windpressure switch failure or blocage in flur duct Clean blockage and impurity of flue duct E4 1 Fan gives error while operate 2 Connection of fan is wrong 1 Change the fan 2 Control the conne...

Страница 16: ...until sufficient air comes The wind pressure outside is too much x x Do not use for a certain time Frozen water x Use again after the melting occurs Insufficient water pressure x Control the water pre...