INSTALLATION MANUAL---Installation of the Indoor unit
5mm
Note : Keep the drain pipe down towards the direction
of the wall hole, otherwise leakage may occur.
1. Decide where to drill the hole in the wall for the pip-
ing ( if necessary ) according to the position of the
indoor unit;
2. Install a flexible flange through the hole in the wall to
keep the latter intact and clean.
The hole must slope downwards towards the exterior
Note : The shape of the mounting plate may be different
from the one above, but installation method is similar .
Indoors
Outdoors
1. Take off the front panel as indicated in the piciure
( by removing the screws)
2. Take out the accessories fromthe indoor unit.
3. Take off the cover as indicated in the piciure ( by
removing a screw ).
4. For the electrical connections, see the circuit diagram
on the right part of the unit under the front panel.
5. Connect the cable wires to the screw terminals by
following the numbering ,Use wire size suitable to
the electric power input (see name plate on the unit)
and according to all current national safety code
requirements.
The cable connecting the outdoor and indoor units
must be suitable for outdoor use.
An efficient earth connection must be ensured.
If the power cable is damaged, it must be replaced by
an authorised Service Centre.
Front panel
Terminal block cover
wiring diagram
20
Drilling a hole in the wall for the piping
Electrical connections---Indoor unit
1
3
3
2
1
2
Before starting installation, decide on the position of the
indoor and outdoor units, taking into account the minim-
um space reserved around the units
Do not install your air conditioner in a
wet room such as a bathroom or laundry etc