DV-302 OPERATION MANUAL
4
2. System Specifications
2.1 Basic Specifications
TABLE1. DV-302 BASIC SPECIFICATIONS
SERVICE
SPECIFICATION
REMARKS
Interface
Analog
FXS
2 port
FXO
1 (back-up port)
Wan
Auto MDI-X, Auto Speed & Duplex
10/100 Base-T
LAN
Auto MDI-X, Auto Speed & Duplex
10/100 Base-T
Protocol
Data
IP protocol
DHCP, NAT, PPPoE, Filtering
VOIP
SIP, RFC2833, T.38, etc
Optional H.323
Voice Capability
G.729°, G.711U, G723.1
Echo Cancellation (G.165), VAD/CNG
Fax Capabilities
Fax/Modem pass-through, T.38
Power
60Hz, DC +12V/1.2A
External Adaptor
(Input voltage: 220VAC)
2.2 Operation Environment Conditions
TABLE 2. OPERATING CONDITIONS
ITEMS
REQUIREMENTS
Temperature
Normal Operation
Optimal Operation
Limited Operation
5 - 40
º
18 - 26
º
2 - 50
℃
º
Humidity
Normal Operation
Optimal Operation
Limited Operation
20 - 65%
45 - 55%
20 - 80%
NOTE
Minimal environmental conditions may not exceed three consecutive days
or 15 total days per year.
Содержание DV-302
Страница 1: ...Internet Telephony Gateway System Operation Manual ...
Страница 2: ......
Страница 65: ...DV 302 OPERATION MANUAL 55 End of Page ...