daviteq WSSFC-ULA-01 Скачать руководство пользователя страница 5

MOUNTING SENSOR ON THE FIXED TOP WALL OF TRASH BIN

MOUNTING SENSOR ON THE MOVABLE LID OF TRASH BIN

MOUNTING SENSOR ON THE MOVABLE LID OF TRASH BIN

MOUNTING SENSOR ON THE OPEN-STYLE TRASH BIN

 

The Sigfox-Ready Ultrasonic level sensor is produced with accuracy as published in th

specification

 of the product

and is ready to use. However, the user may need to configure the A & B factor to give the output as the actual level of
waste in the trash bin. The A & B factor will be calculated as the instructions in 

this link

.

Problems with Sigfox communication like not receiving the packets...please refer to 

this link

 to troubleshoot

the device.
Problems with the sensor functions like not measuring or inaccurate measuring....please refer to 

this link

 to

troubleshoot the sensor part.

Maintenance works

Yes/No

Descriptions

Consumable parts replacement

No

The Sigfox-Ready Ultrasonic level sensor has
no consumable parts, so there is no need to
replace any parts.

Cleaning sensor or device

Yes

As the sensor is installed in the trash bin, it is
needed to clean the device and the transducer
surface by cleaning water with a soft
detergent. Please do not use strong detergent
or chemical solvents to clean as they can
damage the transducer surface.

Re-calibration / Re-validation

Yes

The transducer may need to be re-calibrated
when necessary. Please refer to this link for
the procedure of calibration.

To get a strong RF signal, please refer to 

this link

.

1.5.3 Sensor calibration

2. Maintenance

2.1 Troubleshooting

2.2 Sensor maintenance

Содержание WSSFC-ULA-01

Страница 1: ...022 To use this product please refer step by step to the below instructions Operating Principle Uplink Payload Battery Connect to Sigfox Network Installation Troubleshooting Configuration Calibration Specification Warranty and Support WSSFC ULA is a Sigfox Ready sensor with an integrated ultrasonic level sensor that can measure the waste level in the trash bin It can be installed in the trash bin ...

Страница 2: ...send the uplink message to get the data immediately This message is called FORCE_DATA The payload will provide data like distance from the sensor to waste waste level battery level alarm status It can be forced by applying the magnet key on the reed switch in 1s Case 6 If users want to change the configuration immediately they don t need to wait up to 1 day for the HEART_BEAT message instead they ...

Страница 3: ...e delivery The settings of Device ID Device PAC and RC could also be read from the device memory map Please reference section 3 2 Sensor configuration for details Step 2 Add the device to Sigfox Backend Step 3 Install the batteries to the device After installing the battery in 60 seconds the first data packet will be sent to the Sigfox network After receiving the first data packet the time of anot...

Страница 4: ...f the trash bin Please refer below to some examples of the installation DIMENSIONS OF PRODUCT 1 5 1 Battery insertion 1 5 2 Mounting sensor in trash bin Notes The sensor must not be installed in a complete metallic trash bin as the RF signal cannot pass thru the metallic wall The sensor can be mounted on the movable lid The lid will be closed all the time it will be opened in a short time ...

Страница 5: ...or functions like not measuring or inaccurate measuring please refer tothis link to troubleshoot the sensor part Maintenance works Yes No Descriptions Consumable parts replacement No The Sigfox Ready Ultrasonic level sensor has no consumable parts so there is no need to replace any parts Cleaning sensor or device Yes As the sensor is installed in the trash bin it is needed to clean the device and ...

Страница 6: ...ery life cyclic_data_period Default 1800s Interval time to send an uplink message regardless of any conditions sensor_boot_time Default 500mS This value will affect the measurement accuracy DO NOT change this value num_of_sample Default 30 The higher value the more filtering This filtering can eliminate the errors caused by the un uniformed surface of the waste and or the moving of the lid This va...

Страница 7: ...ensor or Input Type Read Write Parameter Table Modbus Register Decimal Modbus Register Hex Function Code Read Function Code Write No of Registers Description Range Default Format Property Comment 270 10E 3 16 4 CURRENT_CONFIGURATION hex Read Write Check the Payload Document section 5 Payload for downlink message for more information 274 112 3 16 1 SERVER_CONFIG uint16 Read Write 0 Send to Sigfox N...

Страница 8: ...rite A number of samples for filtering function The higher value the more filtering Please refer to this link Please refer to the detailed specifications inthis link For warranty terms and support procedures please refer tothis link Use cases Case studies White papers END Revision 20 Created Wed Aug 24 2022 2 40 PM by Lộc Vĩnh Nguyễn Updated Thu Aug 25 2022 9 18 AM by Lộc Vĩnh Nguyễn 3 3 Calibrati...

Отзывы: