It is battery-operated and able to connect to any Sigfox network in the World. It supports all frequency zones such as

RC1, RC2, RC3c, RC4, RC5, RC6, and RC7.

For the principle operation of the ULA Ultrasonic level sensor, please refer t

this link.

Please refer to 

this link

 for typical applications.

The device will send uplink messages in the following cases:

Case 1: After power-up in the 60s, the device will send the first message called START_UP. The payload will tell

the user the HW version, FW version, and current configuration of the device;

Case 2: Then, in every interval time (pre-configured), for example, 30 minutes, it will send the message called

CYCLIC_DATA. The payload will tell the user the following data like measured value (Distance and Level), battery

level, alarm status...

Case 3: If the Alarm function was enabled (in the configuration of the sensor), if the measured value passed the

threshold, it will send the uplink message immediately. This message is called ALARM. The payload also tells the

user the data like measured value (distance and level), battery level, alarm status...

Case 4: The HEART_BEAT uplink message will be sent once a day (the default setting can be changed in

configuration) to allow the Sigfox back-end system can send the downlink message for changing the

configuration of the sensor. Please refer to the downlink section for more details. The uplink payload will tell the

user the HW version, FW version, and current configuration of the device;

Case 5: During commissioning, testing, or calibration sensor, the user can force the device to send the uplink

message to get the data immediately. This message is called FORCE_DATA. The payload will provide data like

distance from the sensor to waste, waste level, battery level, alarm status... It can be forced by applying the

magnet key on the reed switch in 1s;

Case 6: If users want to change the configuration immediately, they don't need to wait up to 1 day for the

HEART_BEAT message; instead they can force the device to send a special uplink message so that the device can

get the new downlink message. This uplink message is named PARAMETERS_UPDATE. It can be forced by

applying the magnet key in more than 5s.

The sensor was pre-configured at the factory with default values for configuration parameters that meet the most use

cases. However, depending on the specific use case, the customer can adjust those parameters. Please refer to

section 3.2

 for more details.

The sensor is powered by 2 x AA 1.5V batteries for many years of operation. We recommend using Energizer L91

battery which is very popular and high performance. This battery has a capacity of up to 3500mAh with a working
temperature range from -40 to +60 oC. The instruction for installing the batteries is in 

this link

.

For Battery life estimation, please refer to this link.

1.1.1 What are the typical applications of this sensor?

1.1.2 When does the device send uplink messages?

To change the cycle of data sending, you can change the value of the parameter: CYCLIC_DATA_PERIOD (default

is 1800 seconds).

The alarm thresholds can be changed via downlink or offline tools.

1.1.3 The important configuration parameters

1.1.4 What kind of battery is used for this sensor?

1.2 What's in the package?

The package includes:

01 x Main device

01 x Magnet key

01 x set of stainless steel bolts and nuts

Содержание WSSFC-ULA-01

Страница 1: ...022 To use this product please refer step by step to the below instructions Operating Principle Uplink Payload Battery Connect to Sigfox Network Installation Troubleshooting Configuration Calibration Specification Warranty and Support WSSFC ULA is a Sigfox Ready sensor with an integrated ultrasonic level sensor that can measure the waste level in the trash bin It can be installed in the trash bin ...

Страница 2: ...send the uplink message to get the data immediately This message is called FORCE_DATA The payload will provide data like distance from the sensor to waste waste level battery level alarm status It can be forced by applying the magnet key on the reed switch in 1s Case 6 If users want to change the configuration immediately they don t need to wait up to 1 day for the HEART_BEAT message instead they ...

Страница 3: ...e delivery The settings of Device ID Device PAC and RC could also be read from the device memory map Please reference section 3 2 Sensor configuration for details Step 2 Add the device to Sigfox Backend Step 3 Install the batteries to the device After installing the battery in 60 seconds the first data packet will be sent to the Sigfox network After receiving the first data packet the time of anot...

Страница 4: ...f the trash bin Please refer below to some examples of the installation DIMENSIONS OF PRODUCT 1 5 1 Battery insertion 1 5 2 Mounting sensor in trash bin Notes The sensor must not be installed in a complete metallic trash bin as the RF signal cannot pass thru the metallic wall The sensor can be mounted on the movable lid The lid will be closed all the time it will be opened in a short time ...

Страница 5: ...or functions like not measuring or inaccurate measuring please refer tothis link to troubleshoot the sensor part Maintenance works Yes No Descriptions Consumable parts replacement No The Sigfox Ready Ultrasonic level sensor has no consumable parts so there is no need to replace any parts Cleaning sensor or device Yes As the sensor is installed in the trash bin it is needed to clean the device and ...

Страница 6: ...ery life cyclic_data_period Default 1800s Interval time to send an uplink message regardless of any conditions sensor_boot_time Default 500mS This value will affect the measurement accuracy DO NOT change this value num_of_sample Default 30 The higher value the more filtering This filtering can eliminate the errors caused by the un uniformed surface of the waste and or the moving of the lid This va...

Страница 7: ...ensor or Input Type Read Write Parameter Table Modbus Register Decimal Modbus Register Hex Function Code Read Function Code Write No of Registers Description Range Default Format Property Comment 270 10E 3 16 4 CURRENT_CONFIGURATION hex Read Write Check the Payload Document section 5 Payload for downlink message for more information 274 112 3 16 1 SERVER_CONFIG uint16 Read Write 0 Send to Sigfox N...

Страница 8: ...rite A number of samples for filtering function The higher value the more filtering Please refer to this link Please refer to the detailed specifications inthis link For warranty terms and support procedures please refer tothis link Use cases Case studies White papers END Revision 20 Created Wed Aug 24 2022 2 40 PM by Lộc Vĩnh Nguyễn Updated Thu Aug 25 2022 9 18 AM by Lộc Vĩnh Nguyễn 3 3 Calibrati...

Отзывы: