After the power supply will have 5 minutes to add nodes (value enb_auto_add_sensors = 1 in 5 minutes then = 0), push
button function and hall sensor are only available in the first 5 minutes
Push Button or Hall sensor for the first 5 minutes when power is available:
Press and hold the push button or bring the magnet near the Hall sensor for 2s => see the LED blink once or the
buzzer will ring 1 Beep => release the push button or take the magnet to set Data rate RF 50kbps
Press and hold the push button or bring the magnet near the Hall sensor for 5s => see the LED blink twice or the
buzzer beep 2 Beep => release the push button or take the magnet to set Data rate RF 625bps
Press and hold the push button or bring the magnet near the Hall sensor for 10s => see the LED blinking 3 times
or the buzzer buzzes 3 Beep => release the push button or take the magnet to perform the User factory reset
(User factory reset = reset frequency number, RF transmit power, data rate, Node ID of 40 WS, Modbus operating
parameters, compare time for data status)
If it takes more than 30 seconds, the button will be deactivated
1. Register Node ID automatically
5. Operation Principle
5.1 Describe the Node ID registration of the Wireless sensor on the Co-ordinator