M12-Male Connector
1.
PWR+
: 8...50VDC
3. GND : OVDC, Ground
2.
A
4.
B
Each cable includes wires which are marked labels according to types of connection. (user should not cut these labels
before installation to avoid confusing)
Red:
PWR+(8...50VDC)
Black: PWR-(OVDC)
Green:
B
White:
A
Recommend to use 24VDC power.
The signal cable from sensor should be protected by corrugated hose or the Φ16 plastic tube, keep the cable avoid
high temperature areas.
READ uses command 03, WRITE uses command 16
Modbus
Register
Function
code
#
Register Length Range Default Format Properties Description Unit
Comments
10.2 Follow Labels on Wires
10.3 Follow Wire Colors
10.4 RS485 Communication setting
Default communication parameter:
Baudrate : 19200
Data bit : 8
Stop bit : 1
Parity : None
Modbus Slave address : 30
10.5 Memmap registers