background image

Current Weather Mode

Vantage Pro Console Manual 

Page 19

• Outside Temperature

Press the TEMP / HEAT key to select the outside temperature 
field. Note that the graph icon appears next to the data field.
Temperature data may be displayed in both degrees Farenheit 
(ºF) and Centigrade (ºC).

• Inside Temperature

Press the TEMP / HEAT key again to activate the inside temperature field. 
Again, the graph icon appears next to the data field. 

Humidity

Press the HUM / DEW PT key to select the outside humidity 
field.
Press the HUM / DEW PT key again to activate the inside 
humidity field.
Humidity is displayed in percent relative humidity. See “Relative Humidity” 
on page 37.

Wind Chill

• Current Wind Chill

Press and release the 2ND key, then press the WIND 
/ CHILL key to select the Wind Chill field. 
Wind Chill is displayed either degrees Farenheit (ºF) 
or  Centigrade (ºC). See “Apparent Temperature 
Measures” on page 32.

Dew Point

Содержание and Vantage Pro

Страница 1: ...sor Suite ISS 10 Wireless Vantage Pro Installation 11 Powering your Wireless Vantage Pro 11 Connecting the Wireless Vantage Pro console to the Integrated Sensor Suite ISS 11 Displaying the Vantage Pro...

Страница 2: ...MPERATURE 31 Humidity 31 Wind Speed 32 Direction 32 chill 32 Repair Warranty information 33 One Year Limited Warranty 33 Questions Call the Davis Service Center 33 FCC Part 15 Class B Registration War...

Страница 3: ...Vantage Pro Manual Page 3 AutoClear 42 42 Specifications 43 Function 43 Display Reading 43 Accuracy 43 Temperature 43...

Страница 4: ...Welcome to the Vantage Pro 5 Page 4 Vantage Pro Console Manual...

Страница 5: ...st meteoro logical algorithms A quick glance at the graphical icons predicts the general weather trend A detailed forecast scrolls across the bottom of the screen including predicted xxx what his and...

Страница 6: ...ersonalize the display to suit your needs interests and curiosities To learn more about the display s features see Display on page 21 Console Modes The Vantage Pro console operates in five different m...

Страница 7: ...nting shelf See Optional Accessories on page 8 Ultraviolet UV Radiation Sensor Enables you to measure and display UV wavelength irradiance Required for calculating the burn index Available for Cabled...

Страница 8: ...ree serial port VantageLink 8 extension cord Extends the distance between Vantage Pro console and computer an additional 8 feet Solar Radiation Sensor UV Sensor Mounting Shelf Required for mounting th...

Страница 9: ...xtremely accurate readings As with any precision instrument care must be used in its assembly and use Although installation of the Vantage Pro console is relatively simple following the steps outlined...

Страница 10: ...into an appropriate power outlet The Vantage Pro should run through a brief self test procedure All the dis play segments on the LCD appear and the console will beep number_ times Don Raime figure her...

Страница 11: ...for approximately 1 year Davis Instruments does not recommend using rechargeable NiCad batteries with the Vantage Pro because the Vantage Pro will not recharge them and they will not last as long Afte...

Страница 12: ...ngles settings 1 2 for display on a coffeetable or other low area Choose higher angles settings 3 4 for display on a desk or shelf Don Raime illustrations required here Wall Display 1 Hold the templat...

Страница 13: ...The large LCD display is your window on cur rent and past environmental conditions as well as the place to find the forecast The keyboard allows you to interact with the station computer view current...

Страница 14: ...a special operation key the 2ND key located in the upper right hand corner of the keypad The 2nd key The second key is used in conjuction with other keys to access alternate func tions Above each func...

Страница 15: ...anized to maximize the information available to you The following section explains some of the features that may appear on your con sole 1 Compass Rose The wind rose displays the speed and direction o...

Страница 16: ...set to be accurate 7 2nd button indicator The 2nd indicator icon lights when the 2nd button is pushed 8 Barometric Trend Arrow The barometric trend arrow displays the pressure trend in five dif ferent...

Страница 17: ...avis Weather Ticker is a unique and useful addition to the weather sta tion console The ticker displays a broad spectrum of messages to the con sole user including instructions during console setup Th...

Страница 18: ...t weather variable s current value Selecting a variable also activates that variable s graph Note The graph icon is always displayed next to the active weather variable You can also select any variabl...

Страница 19: ...side temperature field Again the graph icon appears next to the data field Humidity Press the HUM DEW PT key to select the outside humidity field Press the HUM DEW PT key again to activate the inside...

Страница 20: ...re Barometric pressure may be displayed in inches in millime ters mm millibars mb or hectoPascals hPa See Baromet ric Pressure on page 36 Pressure Trend Arrow The Barometric Trend Arrow depicts the cu...

Страница 21: ...e more time to display the THSW Temperature Humidity Sun Wind Index See Apparent Temperature Measures on page 32 All heat indices appear in the same place on the screen and may be displayed like tempe...

Страница 22: ...ord precipitation accumulation for 1 year and 1 month respectively however you may clear start each counting period at whatever date you wish Daily and Storm Rain Daily Rain Press and release the 2ND...

Страница 23: ...age 34 Note To display solar radiation readings you must have installed the optional Solar Radiation sensor XREF ET Evapotranspiration Current ET Press and release the 2ND key then press the BAR ET ke...

Страница 24: ...les feature more possibilities Barometric pressure for example may be displayed in millibars millimeters inches or hectoPascals You may change the units display at any time To change the units for any...

Страница 25: ...h individual high low register If you have enabled the AutoClear for a particular high low see Enabling Disabling AutoClear on page 51 this reading will represent the high low since the time of the Au...

Страница 26: ...a read ing reaches the alarm threshold and continues to sound until the reading rises above the alarm threshold The table below summarizes the Vantage Pro s alarms CONDITION HIGH LOW TIME DATE AUTOCL...

Страница 27: ...ths of an inch ETo is returned to the air at the end of the hour 3 dis crete signals will be generated by the station For this application set the alarm threshold to 0 01 and attach an Alarm Output Mo...

Страница 28: ...Chapter 3 Page 28 Vantage Pro Console Manual...

Страница 29: ...ou are having problems with your unit please check the following guide before sending the unit in for repair You will be able to solve many of the problems yourself If after checking this guide you ar...

Страница 30: ...Van tage Pro See transmitter manual Console not receiving Wireless Check reception A reading has exceeded the limits indi cated in the specifications table For temperature wind speed or rainfall calib...

Страница 31: ...a heater or other internal heat source lamps appliances etc Check calibration number and adjust if necessary Outside temperature seems too low Check calibration number and adjust if necessary Inside t...

Страница 32: ...et a reading try moving the wind cups down about 1 16 1 5mm on the shaft If you still do not get a reading the prob lem may be with the anemometer Call fac tory for return authorization Wind speed rea...

Страница 33: ...to the Maintenance Service and Repair Information brochure included with your station QU E S T IO N S CA L L T H E DA V IS S E R V IC ECE N T E R If you have any questions about our products please c...

Страница 34: ...determined by turning the equipment on and off the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase t...

Отзывы: