36
Installation
(for qualified installers only)
© Travis Industries
6/19/18 - 1418
DaVinci-Cat2+
Overhead Light Connection – Category 2+ Units
When using a Category 2 or greater DaVinci with
overhead lights, the overhead light wires will need to
be connected. Follow the steps below to connect
the wires. For Category 3+ join the sections and
connect the wiring in each section in the same
manor shown below.
1 Remove the baffle from the master module and
place it on the burner area. Locate the bundled wire
connected to the ceramic terminal bar and remove
the wire tie. Direct the wire toward the open end of
the module (see picture to right).
2 On the secondary module, remove the baffle and
place it on the burner area. Join the secondary
module to the master module.
3 Reinstall the baffle in the master module and run
the previously bundled wire to the ceramic bus
bar on the secondary module baffle. Connect the
wires to the terminal block as shown below.
4 Reinstall the secondary module baffle.
5 Secure all excess wiring to make sure it does not contact hot components.
6 When installing the media trays, make sure the notch fits over the overhead light wires.
These wires connect to the overhead
lights on the secondary module.
Place the baffle on
the burner area.
NOTE
: when replacing
the media trays, make
sure the notch fits over
the overhead light wires.
Attach the wires to the terminal block (see pictures below).
NOTE
: The surround panels fit over the
wires, concealing them.