DAVID PRO-DX Скачать руководство пользователя страница 11

11

CLOG REMOVAL

Figure 19

Clogs in the Attachment Hose - Figure 16 

Blockages in the hose can be cleared by removing the attachment hose (12) 
from the machine by squeezing the retaining ring (4) and inserting the oppo-
site end of the hose in the connecting tube (23). Hold the hose upright with 
one hand blocking the top end and switch on the machine. If necessary, 
quickly lift your hand on and off the end of the hose. If this procedure does 
not clear the clog, a straight wire can be inserted into the hose to push out 
the clog. Take care not to puncture the hose with the wire.

Clogs in the Airflow Pathway -  Figure 15 

Most clogs can be removed by accessing the airflow pathway via the orange 
colored access door (38) located on the underside of the power head. 
However, other clogs may only be removed by accessing the airflow pathway 
by disassembling the machine in the opposite sequence of the machine’s 
original assembly (see assembly, page 7).

Figure 16

Figure 15

Clogs in the Cleaning Wand (Active Wand) - Figure 17 

Remove attachment hose (12) from the cleaning wand (16). Then, grip clean-
ing wand handle (11) and remove tube from the machine. A straight wire can 
be inserted into the tube to push out the clog.

    Always unplug vacuum from outlet before removing 
         any clogs!

!

Clogs in the Swivel Neck - Figure 19 

Clogs in the swivel neck (20) can be removed by first pressing the housing 
release button (8) and lifting off the bag housing (6). Lift upward firmly and 
evenly to properly remove the bag housing. Then, release the foot pedal (19), 
lower the swivel neck, check inside the swivel neck channel closest to the 
foot pedal (see arrow), and clean out pathway.

Clogs in Entrance to Filter Bag - Figure 18 

Remove attachment hose (12) from vacuum cleaner (see figure 16) and remove 
front cover (7). Clean out connecting tube (23) and/or entrance to bag (28).

Figure 18

Figure 17

Содержание PRO-DX

Страница 1: ...OWNER S MANUAL PRO DX Art No 06775G 03 2022...

Страница 2: ...he Filter Bag 10 Changing the Pre motor Microfilter 10 Changing the Exhaust Filter 10 Changing the Brush Roller 10 Changing the Sealing Strip 10 Clog Removal 11 Clogs in the Airflow Pathway 11 Clogs i...

Страница 3: ...near flammable vapors or materials Do not operate this vacuum near flammable fluids dust or vapors 21 Maintenance and repairs must be done by qualified personnel 22 Use only original DAVID PRO DX repl...

Страница 4: ...ht will flash Stationary Use Light A warning light will slowly flash when the machine is standing in its upright locked position which causes the power head to rise to its highest point from the floor...

Страница 5: ...the motor with super clean air increases motor life and reduces the possibility of maintenance even after many years of use Also the exhaust air is cleaned to the highest level before being emitted fr...

Страница 6: ...seful tools for cleaning stairs and out of reach areas These two items are sold separately or as part of multiple item attachment kits Another popular attachment is the hand held Turbo brush for remov...

Страница 7: ...e button 8 snaps outward to its locked position Slide the dusting brush clamp 24 onto the handle tube and tighten the screw The handle of the dust ing brush 25 will now snap into the clamp To lock the...

Страница 8: ...lower the handle to a horizontal position useful for vacuuming under beds the foot pedal must be pressed a sec ond time The intermediate stop position can be closed off by the orange colored slider 27...

Страница 9: ...t it rests against furniture or the floor on the back side of the bag housing 6 and the power head is locked in a perpendicular position to the floor Ensure that no children or pets can come into cont...

Страница 10: ...ide the new filter in using the tracks as guides Changing the Brush Roller Figure 13 To change the brush roller 35 push the button 36 remove the side plate 37 turn the brush clockwise a quarter of a t...

Страница 11: ...w pathway by disassembling the machine in the opposite sequence of the machine s original assembly see assembly page 7 Figure 16 Figure 15 Clogs in the Cleaning Wand Active Wand Figure 17 Remove attac...

Страница 12: ...wand not properly inserted SOLUTION 1 Release handle catch push handle down close handle catch See pg 7 2 Use another outlet 3 Replace cable 4 Housing release button 8 should be snapped outward to it...

Страница 13: ...motor microfilter 26 5380GS Internal cover cpl gray black incl pos 40 41 27 1073 Clamp 28 5208 Filter safety catch 29 5210 Return spring 30 5164 Cable clamp 31 5722GS Bag housing locking catch gray bl...

Страница 14: ...ew AM 4x30 DIN 7985 TL 132 5174GS Pile adjustment wheel 133 5060ER Servo motor with gear box 134 5411GS Front bottom plate cpl 135 5412GS Rear bottom plate cpl incl pos 136 139 136 5400 1 Sealing stri...

Страница 15: ...15 NOTES...

Страница 16: ...DAVID Products 13231 Champion Forest Drive Suite 404 Houston Texas 77069 Telephone 281 866 0027 Fax 281 866 0007 Website www DavidProducts com PRO DX...

Отзывы: