background image

GD-04 DAVID 

 

MKS51200_OS1 

2

1.2. 

David can be used as: 

 

A switch with SMS remote control. 

SMS texts for switching particular terminals on/off are 

configurable.  

 

A time-switch 

which can be activated remotely via a mobile phone (the switch-on period is 

configurable from 1 second to 10 hours).  

 

A relay with dialling-in remote control

. Up to 50 tel. numbers can be authorized for each 

relay. Because calls are not answered dialling-in control within GSM is free of charge. (David 
only checks the caller’s number and – if the number is authorized – responds with relay 
activation.) This can be used for parking latch control etc. 

 

A relay with validity-limited dialling-in remote control

. Each authorized number can have 

a limit to the number of calls. When the call count reaches the limit the tel. number is de-
authorized. This can be useful for pre-paid services such as e.g. parking. Any tel. number can 
be re-authorized via SMS by the administrator. 

 

An SMS reporter

. Input A to D activations or deactivations can be reported by SMS and 

optionally confirmed by phone calls. Each input can have its own message texts and up to 8 
tel. numbers programmed. 

1.3. 

David can be supplemented with: 

 

A GD-04A back-up module, 

which provides David with the ability to work 

approx. 12 to 24 

hours continually without an external power supply

,

 

see

 

11.1.

 

 

A GD-04D DTMF module, 

which allows you to control David’s output relays by entering 

numeric codes (DTMF codes) on the telephone keypad during calls, see 11.2.

 

 

A GD-04P link cable

, which allows you to connect David to a PC through a USB port and 

perform any desired configuration using GDLink software.

  

 

A GD-04R radio module

, which allows 

input

 A to D 

activations via wireless buttons or 

detectors 

of the OASiS series and also provides David with the capability of output relay X or 

Y state transmission to UC or AC OASiS receivers. In addition, you can control relays X or Y 

“locally” via RC-8x keyfobs 

(so that an appliance can be controlled both via a mobile phone 

and a keyfob). The module also allows heating control (again locally or remotely via a mobile 
phone) using wireless thermostats of the TP-8x series. 

 

A detailed description of optional accessories can be found in chapter 11. 

2.  David’s SIM card 

 

In order to function, David needs a 

SIM card

, preferably a tariffed one.  

 

Test the 

SIM card 

by using it in your mobile phone – SMS sending and calling must work 

correctly. 

 

Switch off the PIN code protection 

via the phone menu (or set the PIN code to 1234). 

 

Check the GSM signal strength 

in David’s location.

 

3. Installation 

1. The GSM 

antenna should not  be shielded by metals

. If necessary, an external antenna 

designed for the 900/1800MHz GSM band can be connected via a 50

 SMA connector.  

2.  Open the cover and 

release the electronic circuit board

 by pressing the tabs. 

3. 

Mount the rear plastic

 cover at the desired location. 

4. 

Insert a SIM card:

 Open the SIM card case by shifting the moving part in the direction of the 

terminals and tipping it off. Make sure that the card is correctly oriented and insert it. Close 
the SIM card case (fold and re-shift the moving part). 

5. Insert the 

circuit board back

 to its position. 

6.  Do the wiring, see below. 

Содержание GD-04

Страница 1: ......

Страница 2: ......

Страница 3: ...k We hope that the skills of your tiny David will help you manage the giant 1 Basic description SIM Bus connector Battery connection LED indicator RESET jumper GSM antenna Tabs SIM card Output fuses 1 1 David provides 2 output contacts of power relays X and Y each allows up to 5A 250V 4 input terminals A to D for SMS reporting the inputs react to a connection or disconnection to or from a common G...

Страница 4: ...D 04P link cable which allows you to connect David to a PC through a USB port and perform any desired configuration using GDLink software A GD 04R radio module which allows input A to D activations via wireless buttons or detectors of the OASiS series and also provides David with the capability of output relay X or Y state transmission to UC or AC OASiS receivers In addition you can control relays...

Страница 5: ...upply can be connected to these terminals they can only be controlled via a potential free switch contact Example of wiring a switch to input A Switch 5 Initial powering up 1 Turn the power supply on registering to the GSM network is indicated by the LED flashing if no indication occurs check the power supply wiring 2 After GSM registration the LED stops flashing usually within 1 minute Continued ...

Страница 6: ... a USB port the cable is supplied separately GDLink software is available either in the GD 04P s package or on the www jablotron cz web site David s communication protocol is available for use by other computer programs which can thus utilize GD 04 transfers including programming instructions or GSM status information 6 3 SMS instructions David can also be configured via SMS instructions from your...

Страница 7: ...ed by SMS Received SMSes with unrecognised instructions can be forwarded to the so called service number see table 1 If you are not sure whether any other text will be automatically added to the SMS on its way to David for example when using an SMS internet gate type the message like this instructions Example The SMS text 1 1 www heating on is interpreted as heating on 8 Remote operation via diall...

Страница 8: ...10 Reset to factory defaults You can reset David to the factory default settings via the SMS instruction PC RST where PC is a valid access code see Table 1 Another option is to use the RESET jumper next to the SIM case a Turn the power supply off including the backup module if used b Connect the RESET jumper turn the power supply on and disconnect the jumper after about 5s Note Performing a RESET ...

Страница 9: ... be applied to extend David s working range 11 3 2 Transmitting X or Y relay status to an UC 82 or AC 82 receiver Enter mode 4 on the receiver and press the XY button on David s GD 04R module This establishes a connection so that the receiver s relay status mirrors David s relay status There is no limit to the number of UC AC receivers which can be connected this way 11 3 3 Wireless device input a...

Страница 10: ... the temperature in your house An A assigned thermostat controls relay X a B assigned thermostat controls relay Y This way heating control is established supplemented by the reporting described above Thermostats enrolled to C or D inputs only provide reporting Normally an A or B enrolled thermostat switches the heating via the X or Y relay so that temperature comfort is maintained However you can ...

Страница 11: ...ng to steps 3 to 5 7 Your PC now has two new devices after successful installation Jablotron serial interface as a serial port COM driver and the USB device with the same name as the driver for USB 8 Install the GDLink software on your PC 9 Connect the GD 04P cable into David s digital bus connector GDLink is now ready to be started 11 4 6 Using GDLink The program allows for o Retrieval and modifi...

Страница 12: ...301489 7 EN 55022 and EN 50130 4 Radio transmissions ETSI EN 301419 1 and EN 301511 Environment II indoor general 10 C to 40 C Dimensions without antenna 76 x 110 x 33 mm GSM antenna connected to SMA connector Jablotron Ltd hereby declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The original of the conformity assessmen...

Страница 13: ... access code see 6 3 Example PC ARX heating on DRX heating off Function Instruction Description Factory default SMS when activated SMS when deactivated Input A Phone numbers SMS when activated SMS when deactivated Input B Phone numbers SMS when activated SMS when deactivated Input C Phone numbers SMS when activated SMS when deactivated Input D Phone numbers ON command SMS DTMF code OFF command SMS...

Страница 14: ...in total n limit in the number of calls 1 to 99 exceeding the limit removes the number from the list this is reported to the service number by SMS Example LDX 777123457 31 authorises a new number for relay X control for a maximum of 31 calls empty list Erasing tel numbers authorised for relay control EDX x x x x Use EDY for relay Y x x tel number The numbers up to 50 are removed from the list Exam...

Страница 15: ...xx x numeric code up to 8 digits Example CAY 1234 Instruction CAY erases the code none DTMF code to switch relay OFF 1 CDX xx x Use CDY for relay Y xx x numeric code up to 8 digits Example CDY 1234 Instruction CDY erases the code none Wireless device assignements2 see 11 3 2 a 11 3 3 LRN n xx x n x n A B C D X or Y input or output the device should be assigned to xx x device production code last 8...

Страница 16: ......

Отзывы: