GENERAL SAFETy RULES 

!

WARNING

  Read all instructions. Failure to follow all instructions listed 

below may result in hazardous radiation exposure, electric 

shock, fire and/or serious injury. 
If glass light house breaks when dropped, contact customer service 

immediately. 

Broken glass can cause laceration hazard and unit to 

lose its IP rating. 

IEC 60825-1:2007-03 

< 1 mW, 635 nm

DO NOT direct the laser beam at persons or animals and do not 

stare into the laser beam yourself. This tool produces laser class 2 

laser radiation and complies with 21 CFR 1040.10 and 1040.11 

except for deviations pursuant to Laser Notice No. 50, dated June 

24, 2007. This can lead to persons being blinded.

DO NOT remove or deface any warning or caution labels.  

Removing labels increases the risk of exposure to laser radiation.

Use of controls or adjustments or performance of procedures other than those 

specified in this manual, may result in hazardous radiation exposure.
ALWAyS make sure that any bystanders in the vicinity of use are made aware 

of the dangers of looking directly into the laser tool.
DO NOT place the laser tool in a position that may cause anyone to stare into 

the laser beam intentionally or unintentionally. 

Serious eye injury could result.

ALWAyS position the laser tool securely. 

Damage to the laser tool and/or 

serious injury to the user could result if the laser tool falls. 

ALWAyS use only the accessories that are recommended by the manufacturer 

of your laser tool.

 Use of accessories that have been designed for use with 

other laser tools could result in serious injury or unsatisfactory performance.

DO NOT use this laser tool for any purpose other than those outlined in this 

manual.

 This could result in serious injury or unsatisfactory performance.

DO NOT leave the laser tool “ON” unattended in any operating mode.
DO NOT disassemble the laser tool.

 There are no user serviceable parts inside. 

Do not modify the product in any way. Modifying the laser tool may result in 

hazardous laser radiation exposure.

Содержание 3900HV

Страница 1: ...900HV www davidwhite us com 3900HV Rotary Laser Owner s Guide FOR CUSTOMER SERVICE PARTS AND REPAIR CALL 765 581 4097 IMPORTANT IMPORTANT IMPORTANTE Read Before Using Lire avant usage Leer antes de usar ...

Страница 2: ...xtremely rugged field use Like all precision instruments however they should be treated with reasonable care to prolong life and accuracy All instruments are adjusted when they are shipped from the factory It is the customer s responsibility to check and to ensure instruments are adjusted prior to using David White is not responsible for errors caused by instruments that are out of adjustment Cont...

Страница 3: ... 3 3900HV 7 3900HV d b a c 1 2 3 4 6 5 ...

Страница 4: ... 4 13 9 8 10 12 11 10 ...

Страница 5: ...may result in hazardous radiation exposure ALWAYS make sure that any bystanders in the vicinity of use are made aware of the dangers of looking directly into the laser tool DO NOT place the laser tool in a position that may cause anyone to stare into the laser beam intentionally or unintentionally Serious eye injury could result ALWAYS position the laser tool securely Damage to the laser tool and ...

Страница 6: ...ery chemistries Dispose of or recycle batteries per local code DO NOT dispose of batteries in fire Keep batteries out of reach of children Personal safety Stay alert watch what you are doing and use common sense when operating a tool Do not use a tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating a tool may result in serious perso...

Страница 7: ...switch does not turn it on and off Any tool that cannot be controlled with the switch is dangerous and must be repaired Store idle tool out of the reach of children and do not allow persons unfamiliar with the tool or these instructions to operate the tool Tools are dangerous in the hands of untrained users Maintain tools Check for misalignment or binding of moving parts breakage of parts and any ...

Страница 8: ...dow for Plumb Beam 8 Trivet Attachment for Vertical Laydown Positioning 9 5 8 11 Tripod Mount 10 Mounting Clip with Lever 11 Trivet Hinge 12 Slots for Mounting 13 Alignment Marker for Laydown Position Technical Data Description 3900HV Accuracy Horizontal leveling 3 16 in at 100 ft 4 5mm at 30m Accuracy Vertical Laydown 1 4 in at 100 ft 6mm at 30m Working Range diameter without Laser Detector appro...

Страница 9: ...r extended periods When storing for extended periods the batteries can corrode and discharge themselves Un screw the battery compartment screw 4 at the bottom front of instrument base Remove the batteries Use either alkaline batteries or Ni Mh batteries When inserting alkaline batteries pay attention to the correct polarity according to the representation on the inside of the battery compartment A...

Страница 10: ...nstrument reacts sensitively to ground vibrations and position changes Therefore pay attention that the position of the instrument is stable in order to avoid operational interruptions due to re leveling Switching On and Off Press the Power ON OFF 3a keypad and allow the laser instrument to self level If the power indicator LED blinks the voltage of the batteries is low and batteries need to be re...

Страница 11: ...f the scanning area can be adjusted Press the Clock Wise 180 10 45 90 RPM and Counter Clock Wise 180 10 45 90 RPM Beam Positioning keypads on the remote control Slope Automatic Mode When the instrument is set upright for horizontal rotation the slope can be adjusted by using Manual Mode 3b Press the Manual Automatic keypad 180 10 45 90 RPM the instrument will enter into the mode of manual adjustme...

Страница 12: ...strument each time before starting your work A free measuring distance of 165 ft 50m on a firm surface is required for the check A reversal measurement must be carried out over both axes X and Y each positive and negative 4 complete measurements Mount the instrument in the horizontal position onto a tripod or place it on a firm and level surface 100 ft 30m from a wall Switch the instrument on Posi...

Страница 13: ...tate the instrument by 180 allow it to level in and mark the center point of the laser beam on the wall point H2 100 ft 30 m H1 Y1 100 ft 30 m H1 H2 Y2 100 ft 30 m 1 5 ft 0 5 m A H1 B 100 ft 30 m 1 5 ft 0 5 m A H1 H2 B 100 ft 30 m 1 5 ft 0 5 m A H1 D H3 H2 B 100 ft 30 m 1 5 ft 0 5 m A H1 H2 B D 180 100 ft 30 m 100 ft 30 m 180 180 The difference D of both marked points H1 and H2 on wall is the actu...

Страница 14: ...tmospheres such as in the presence of flammable liquids gases or dusts Sparks can be created in the remote control which may ignite the dust or fumes The remote control can be used up to a maximum of 65 feet 20m away from the instrument The remote must be pointed towards the instrument for proper operation All the features of the 4200HV can be controlled using the remote Requires 2 AA Alkaline bat...

Страница 15: ...a rotary laser instrument perfect for use in outdoor conditions where sunlight and distance may make locating the beam more difficult The laser detector includes a rod clamp which allows to mount the detector onto square round or oval sighting rods LD20 features LD20 4 9 10 5 6 3 2 1 8 7 c b e f g a d ...

Страница 16: ...harge LD20 preparations The numbering of the product features shown refers to the illustration of the tool above 1 On Off switch 2 Center mark 3 LCD Display 3a Fine adjustment indicator 3b Coarse adjustment indicator 3c Direction indicator move downward 3d Center indicator 3e Direction indicator move upward 3f Audio signal indicator 3g Battery low indicator 4 Reception area for the laser beam 5 Bu...

Страница 17: ...thorized after sales service center for Dave White s SitePro instruments In all correspondence and spare parts orders please always include the model number and serial number of the instruments All precision instruments should be cleaned lubricated checked and adjusted ONLY at a qualified instrument repair station or by the manufacturer at least once a year In case of repairs send in the instrumen...

Страница 18: ...ed Service Center Please include a dated proof of purchase with your tool For locations of nearby service centers please call 1 855 354 9881 THIS LIMITED WARRANTY DOES NOT APPLY TO ACCESSORY ITEMS SUCH AS TRIPODS RODS HAND LEVELS FIELD SUPPLIES TAPES MOUNTING DEVICES AND OTHER RELATED ITEMS THESE ITEMS RECEIVE A 90 DAY LIMITED WARRANTY To make a claim under this Limited Warranty you must return th...

Страница 19: ...VE OTHER RIGHTS WHICH VARY FROM STATE TO STATE IN THE U S OR PROVINCE TO PROVINCE IN CANADA AND FROM COUNTRY TO COUNTRY THIS LIMITED WARRANTY APPLIES ONLY TO PRODUCTS SOLD WITHIN THE UNITED STATES OF AMERICA CANADA AND THE COMMONWEALTH OF PUERTO RICO FOR WARRANTY COVERAGE WITHIN OTHER COUNTRIES CONTACT YOUR LOCAL SITEPRO DEALER OR IMPORTER David White is a registered trademark and offered exclusiv...

Страница 20: ...42348D3900 09 15 Printed in China Dave White s SitePro 7619 S 1150 E Otterbein IN 47970 Tel 1 765 581 4097 ...

Отзывы: