3. OPERATION 

 
Before reading detailed instructions on how to use all the weighing functions that are built into your scale, please 
read the following important guidelines: 
 

o

 

Always be sure that the display shows `Zero` before use, if it does not then please press the ZERO key. 

o

 

The equipment is designed to detect when a stable weight is achieved, your reading should be taken at this 
point. 

 
 

3.1

3.1

3.1

3.1. . . . LCD SYMBOL DESCRIPTION

LCD SYMBOL DESCRIPTION

LCD SYMBOL DESCRIPTION

LCD SYMBOL DESCRIPTION    

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Display

Display

Display

Display    

Description

Description

Description

Description    

[

 0 

Zero  symbol:  If  the  scale  does  not  show  exactly  zero  value  although  the  scale  pan  is 
unloaded, press the [[[[

0

0

0

0

] key. After a short waiting time, the scale will be zeroed again. 

 

Stable symbol: If the display shows the stabilization display [

ο

], the scale is in the stable 

condition.  When  the  scale  is  in  the  unstable  condition,  the  stabilization  display  [

ο

disappears. 

Minor weight: Weight under zero. 

LOW 

Low Battery: Battery need to change or replace. 

BMI 

 

Calculated value of the body mass index (BMI). 

HOLD 

 

Hold function / saving function is active. 

PRE-TARE 

 

Initially set tare value is active. 

NET 

 

The net weight is displayed. 

WEIGHT 

 

The present weight value is displayed. 

    

PRE-TARE Indication 

kg 

 

NET WEIGHT Indication 

WEIGHT Indication 

HOLD Indication 

Stable symbol 

Minor weight 

Zero symbol 

Low Battery 

Содержание PS1300S

Страница 1: ...PS1300S USER S MANUAL MA18 02 B 12 09 2011 www davicia com ...

Страница 2: ...11 5 5 5 5 MAINTENANCE MAINTENANCE MAINTENANCE MAINTENANCE AND CLEANING AND CLEANING AND CLEANING AND CLEANING 5 1 Instructions for charge and connect 5 2 Instructions for replacing batteries 5 3 Environmental 5 4 Equipment disposal 12 12 12 12 12 6 6 6 6 TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING 13 7 7 7 7 TECHNICAL SPECIFICATIO TECHNICAL SPECIFICATIO TECHNICAL SPECIFICATIO ...

Страница 3: ...USER S MANUAL MA18 02 B 3 1 DESCRIPTION 1 Display unit 2 Scale platform 3 Adjustable feet 4 Level 1 2 3 4 ...

Страница 4: ...d o Ensure the voltage marked on the power supply unit matches your main power supply o This device is designed for use indoors o Observe the permissible ambient temperatures for use o The device meets the requirements for electromagnetic compatibility Do not exceed the maximum values specified in the applicable standards 2 2 2 2 1 1 1 1 LOCATION AND SETTING LOCATION AND SETTING LOCATION AND SETTI...

Страница 5: ...ription 0 Zero symbol If the scale does not show exactly zero value although the scale pan is unloaded press the 0 0 0 0 key After a short waiting time the scale will be zeroed again Stable symbol If the display shows the stabilization display ο the scale is in the stable condition When the scale is in the unstable condition the stabilization display ο disappears Minor weight Weight under zero LOW...

Страница 6: ...merical value Entering digits 3 3 3 3 3 3 3 3 WEIGHING WEIGHING WEIGHING WEIGHING Switch on the scale with the ON OFF ON OFF ON OFF ON OFF key The diagnostic scale self check is performed and then the software version is displayed The scale is ready for weighing when the 0 00 kg 0 00 kg 0 00 kg 0 00 kg weight display is shown NOTE If 0 00 kg won t display on the screen press 0 0 0 0 key to zero th...

Страница 7: ...cale takes some measuring values and then the calculated average value is displayed o Remove the object baby from the scale platform The object baby s weight reading will remain on the display o Press the HOLD HOLD HOLD HOLD key again to return the scale to the normal weighing mode o HOLD function can be activated before or after putting the weight on the platform In case of weighing babies that m...

Страница 8: ... tare weight For example Press 1 to assign position 1 to preset tare weight The display will blink and makea beep sound NOTE You can assign any other position from 1 5 to pre tare weight Enter Weight Using 0 9 Keys Description Description Description Description Example Example Example Example Press PRE TARE key and the extreme left digit will blink Enter PRE TARE weight using 0 9 keys For example...

Страница 9: ...e Long press PRE TARE key for 3 seconds the display will show the blinking m sign Press numeral key 1 5 to choose pre Press numeral key 1 5 to choose pre Press numeral key 1 5 to choose pre Press numeral key 1 5 to choose pre tare value tare value tare value tare value Press ENTER key to confirm the pre tare weight the instrument will automatically perform tare function Press PRE TARE key to retur...

Страница 10: ...ected to PC to transfer the weighing results 1 Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories Communication Hyper Terminal 2 New Connection Description Give new connection a name then click OK 3 Select Your COM Port Click Connect to select your COM port Usually there s only one option for select Then click OK 4 Port Settings Click Bits per second to...

Страница 11: ...INT FUNCTION The Weighing BMI and Height results can be printed out for records using RS232 interface cable included in accessory kit which is connected with the round plug at the back terminal After weighing and calculating BMI simply press PRINT PRINT PRINT PRINT key to print out the results The format presented below is the standard format of results print out and cannot be changed ...

Страница 12: ...TRUCTIONS FOR REPLACING BATTERIES INSTRUCTIONS FOR REPLACING BATTERIES INSTRUCTIONS FOR REPLACING BATTERIES INSTRUCTIONS FOR REPLACING BATTERIES o Remove the battery cover o Take the battery housing out o Replace new batteries o Make sure batteries are well installed o Reinstall the battery housing 1 Reinstall the battery cover 5 3 5 3 5 3 5 3 ENVIRONMENTAL ENVIRONMENTAL ENVIRONMENTAL ENVIRONMENTA...

Страница 13: ...s fault on the scales such as faulty load cell or wiring Please contact the local service representative Counting error too low Indicates that the signal from the load cell is too low This error is normally caused by a serious fault on the scales such as faulty load cell or wiring Please contact the local service representative Zero count over calibration zero range 10 while power on Please recali...

Страница 14: ...y 300 kg x 100 g LCD Display 1 0 inch LCD display with 5 and 1 2 digits Max external dimensions 360 x 520 x 1020 mm Power supply AC adapter 15V 300mA Rechargeable Battery Key Functions ON OFF ZERO PRINT BMI HOLD PRE TARE TARE CLEAR ENTER 0 9 M1 5 Operation temperature 5ºC 35ºC ...

Страница 15: ...fied free of charge upon presentation of the purchase receipt for the appliance No other rights can be taken into consideration Return shipment is at the customer s expense if the appliance is anywhere other than at the customer s headquarters In the event of damage during shipment guarantee rights will be granted only if the appliance is shipped in the original packaging You are therefore recomme...

Страница 16: ...NICO Type Electronic equipment Finalidad Prevista Equipo pesapersonas Intended Use Weighing equipment CUMPLE LOS REQUISITOS DE LAS DIRECTIVAS CONFORMS WITH THE REQUISITES OF THE DIRECTIVES EC Directive 2004 108 EC Directiva de Compatibilidad Electromagnética Electromagnetic Compatibility Directive EC Directive 2006 95 EC Directiva de Baja tensión Low Voltaje Directive EC Directive 93 42 EEC Aplica...

Страница 17: ...uments are available on the web www davicia com www davicia com www davicia com www davicia com C Murcia 35 Nave G Pol industrial Can Calderón E 08830 Sant Boi de Llobregat Barcelona Spain Tel 34 93 654 32 32 Fax 34 93 654 16 62 info davicia com www davicia com ...

Отзывы: