background image

1

7

5

2

3

6

4

~ 2 ~

SOLAR WARNING: This Equipment is not suitable for use with Solar Panel Power Supply.

Congratulations on your purchase of an TotalFlo quality water pressure system. All components have been designed and 

manufactured to give trouble free, reliable operation.

Before installing your new pump, please read all instructions carefully as failures caused by incorrect installation or 

operation are not covered by the guarantee. Your pump is designed to handle clean water. The pump should not be used 

for any other purpose without specific referral to your TotalFlo reseller. The use of the pump to handle flammable, corrosive 

and other materials of a hazardous nature is specifically excluded.

1. Delivery outlet - 1” BSP(M)

2. Suction inlet - 1”BSP(F) for TF40J and TF50J

 

1¼”BSP(F) for TF117MS

3. Pump body

4. Motor

5. Priming port and plug

6. Drain port and plug

7. Pressure Controller

Do not use this pump to pump flammable fluids, such as petrol or diesel fuels.

This pump is designed to pump clean fresh water free of solids.

Choosing a Site

Choose a site with a firm base and as close to the water source as possible with 

correct power supply.  Make sure your pump is always connected to an adequate, 

reliable source of clean water.

Housing your Jet Pump or Multistage Pump

To protect your pump from the weather, make sure the cover provided is water proof, 

frost free and has adequate ventilation.

The pump should be horizontally mounted on a firm base allowing for drainage, to 

avoid damage to flooring etc., that over time may occur from leaking pipe joints or 

pump seals.  Do not mount the pump vertically.

WARNING: Some insects, such as small ants, find electrical devices  attractive for various reasons.  If your pump 

enclosure is susceptible to insect infestation you should implement a suitable pest control plan.

Power Connection

The pump motor is fitted with an earthed three pin plug & lead.

The installer is responsible for the correct connection of the electrical supply to the pump motor.

•  Make sure the supply voltage and frequency is the same as the nameplate.

•  Make sure that there is a sound earth connection available.

In accordance with AS/NZS 60335.2.41 we are obliged to inform you that this pump is not to be used by children or infirm 

persons and must not be used as a toy by children. This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 

supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be 

supervised to ensure that they don’t play with the appliance.

POWER CONNECTION

Connect lead to power supply designated on pump label.  Do not use long extension leads as they cause 

substantial voltage drop, poor pump performance and may cause motor overload.

EARTH CONNECTION

The pump power lead includes an earth pin on the plug, which MUST be correctly connected to a suitable earth 

on the electrical supply.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in 

order to avoid a hazard.

Maximum Total Head:

TF40J = 35m

TF50J = 41m

TF117MS = 41m

Отзывы: