Suction Lines / Lift

The Torrium2 controller has an in-built non-return (check) valve fitted. In flooded 
suction installations there is no need to have a suction non-return valve.

Installations with flooded suction require a gate or isolating valve so water 
supply can be turned off for pump removal and servicing.

In suction lift installations a footvalve will normally be required for the pump 
to retain prime.

In some suction lift installations there may be good reason to remove the 
oring from the inbuilt check valve to ensure that the discharge pressure 
is also applied to the suction line and footvalve. (NOTE: The check valve, 
minus the oring, needs to be replaced in the Torrium2 controller to properly 
direct water flow over the flow sensor.) Removing the oring from the 
inbuilt check valve could be where the suction line was very long or where 
there was concern regarding a leaking footvalve. This may not always 
be applicable and it is acceptable to retain the inbuilt check valve in the 
Torrium2 on suction lifts with good suction plumbing.

Should the oring of the inbuilt check valve be removed though, an 
additional accumulator should be fitted to the Torrium2, or discharge 
pipework as applicable, to ensure the pump is not cycled on shut down. 
The size of this accumulator will depend on the size, length and type of 
pipe used on the suction.

 

Discharge Connections

The Torrrium2 offers the option of using one or both outlet options.
Use of the horizontal outlet only allows for either:
1. Easy access to prime the pump and / or the removal of the inbuilt 

Torrium check valve

2. Fitment of a pressure tank (up to 20 litre capacity) onto the priming port 

/ vertical discharge port

If you use the vertical outlet instead or as well, you need to consider 
access to the inbuilt check valve in the Torrium.  Davey suggest you use a 
flexible connection and / or union connection to allow for ease of access to 
the check valve.

Pipe Connections

For best performance use P.V.C. or polythene pipe at least the same 
diameter as the Torrium2 controller outlet.
Larger diameter pipe may be used to minimise resistance to flow when 
pumping longer distances.
Flexible pipe will help alignment during installation, as well as reduce noise 
transfer during operation.

Abrasive Materials - The pumping of abrasive materials will cause damage to 
the pressure system which will then not be covered by the guarantee.

Maintenance

       

The only regular attention your new pressure system requires is to check any 

supplementary pressure tank’s air charge every 6 months. This can be checked at 

the air valve with a tyre gauge. Do not charge tank to a higher pressure than 70% of 

the maximum system pressure.

To check air pressure in tank:

1.  Switch off pump.

2.  Open outlet nearest to pump to release water pressure.

3.  Charge tank to desired setting using air pump and check with tyre gauge.

4.  Switch on.

5.  Close outlet.

*NOTE:

a)  For protection, Davey pump motors are fitted with an automatic “over temperature”  

cut-out. Constant tripping of this overload device indicates a problem e.g. low 

voltage at pump, excessive temperature (above 50°C) in pump enclosure.

b)  The Torrium2 controller may have to be reset after rectifying any of the above 

operating troubles. This is done by pushing in the “Prime” button and releasing it 

after 2 seconds.

 

During servicing, use only approved, non-petrochemical based 

 

oring and gasket lubrication. If unsure, consult your Davey

 

Dealer for advice.

WARNING :  Under no circumstances should Torrium2 controller be 

disassembled.  Failure to observe this warning will expose persons to 

the possibility of personal injury and may also result in damage to other 

property.  Do not dismantle, no user serviceable parts, spring under 

pressure.

Содержание Torrium2

Страница 1: ...difficulties or if the product is faulty or defective advise you on how to have your Davey product repaired obtain a replacement or a refund Your Davey Two Year Guarantee naturally does not cover nor...

Страница 2: ...Before installing your Torrium2 controller please read all instructions carefully as failures caused by incorrect installation or operation are not covered by the guarantee Your Torrium2 controller is...

Страница 3: ...60Hz models use suffix Y USA and 220 240V 60Hz models use suffix P USA Fitment of the Torrium2 controller The Torrium2 controller fits onto the outlet of the pump The Torrium2 controller is designed t...

Страница 4: ...able to be used as a discharge port During servicing use only approved non petrochemical based oring and gasket lubrication If unsure consult your Davey Dealer for advice WARNING Do not use hydrocarbo...

Страница 5: ...socket since both Torrium2 prime port and tank are 1 male threads DO NOT USE THREAD SEALING COMPOUNDS HEMP OR PIPE DOPE Trouble Shooting Check List a PUMP HAS STOPPED OR MOTOR RUNS FOR SHORT PERIOD ON...

Страница 6: ...er access to the inbuilt check valve in the Torrium Davey suggest you use a flexible connection and or union connection to allow for ease of access to the check valve Pipe Connections For best perform...

Страница 7: ...we are obliged to inform you that this appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they ca...

Страница 8: ...Water return mode will restart the pump automatically if the Torrium2 detects water flow through it Electrical Power Surge Protection An electrical power surge or spike can travel on the supply lines...

Отзывы: