Selection

The Torrium2 controller is available in different versions to suit different 
single phase pump models up to 10amp maximum run current. Please 
ensure you have the right unit for the pump model (see table below).

  Torrium2
  Model

To Suit

Standard 

Voltage/Hz

Pump System

  TT45

110-240

/ 50-60

A pump or total system* capable of no more than 450kPa maximum 

shut-off head or dead head pressure.

  TT70

110-240

/ 50-60

A pump or total system* capable of at least 450kPa, but no more than 

750kPa maximum shut-off head or dead head pressure.

*’total system’ includes maximum incoming pressure and pump pressure (e.g. mains boosting)
NOTE: While Torrium2 can be connected to pumps of nearly all single phase voltages 
commonly used worldwide, special models with power leads to suit particular regions or 
countries are made. For example, for North America, 110-120V, 60Hz models use suffix ‘Y/
USA and 220-240V 60Hz models use suffix “P/USA”

Fitment of the Torrium2 controller

The Torrium2 controller fits onto the outlet of the pump.
The Torrium2 controller is designed to fit in place of a Davey Torrium or 
Hydrascan, a Presscontrol or can be installed to replace another form of 
controller eg. pressure switch.

 

NOTE: The above table assumes the pump is installed with a small flooded

 

suction, or a normal suction lift.  High incoming pressures may require a

 

different installation procedure - consult your Davey dealer for assistance.

14

3

 

WARNING: Some insects, such as small ants, find electrical devices

 

attractive for various reasons.  If your pump enclosure is susceptible

 

to insect infestation you should implement a suitable pest control plan.

DO NOT USE THREAD SEALING COMPOUNDS, HEMP OR PIPE DOPE!

Figure 1

Rotary Coupling Inlet
1” Male

Horizontal Outlet
1” Male

Priming Cap which covers the 1” Male Vertical Outlet 
and access to the internal check valve.

Status Indicator
Lights

Prime Button

Pressure
Indicator
Window

Содержание Torrium2

Страница 1: ...difficulties or if the product is faulty or defective advise you on how to have your Davey product repaired obtain a replacement or a refund Your Davey Two Year Guarantee naturally does not cover nor...

Страница 2: ...Before installing your Torrium2 controller please read all instructions carefully as failures caused by incorrect installation or operation are not covered by the guarantee Your Torrium2 controller is...

Страница 3: ...60Hz models use suffix Y USA and 220 240V 60Hz models use suffix P USA Fitment of the Torrium2 controller The Torrium2 controller fits onto the outlet of the pump The Torrium2 controller is designed t...

Страница 4: ...able to be used as a discharge port During servicing use only approved non petrochemical based oring and gasket lubrication If unsure consult your Davey Dealer for advice WARNING Do not use hydrocarbo...

Страница 5: ...socket since both Torrium2 prime port and tank are 1 male threads DO NOT USE THREAD SEALING COMPOUNDS HEMP OR PIPE DOPE Trouble Shooting Check List a PUMP HAS STOPPED OR MOTOR RUNS FOR SHORT PERIOD ON...

Страница 6: ...er access to the inbuilt check valve in the Torrium Davey suggest you use a flexible connection and or union connection to allow for ease of access to the check valve Pipe Connections For best perform...

Страница 7: ...we are obliged to inform you that this appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they ca...

Страница 8: ...Water return mode will restart the pump automatically if the Torrium2 detects water flow through it Electrical Power Surge Protection An electrical power surge or spike can travel on the supply lines...

Отзывы: