background image

4

TESTING (MUST BE COMPLETED BY QUALIFIED PERSONNEL)

1.  Double check that all plumbing is connected correctly and that the supply is    

available for heater and control box.

2.  Before switch on check that gate valves (if fitted) are open and the thermostat is  

turned fully anti clockwise.

3.  The heater lid should be off for setting up pressure switch adjustment.
4.  Apply a voltmeter, neon indicator or such test device at element terminal or 

control relay. If preferred, a current meter could be used.

5.  Apply power. There should be no indication that the element is alive.
6.  Start pump and check for water leaks, paying particular attention to the join    

between heating head and body.

7.  After checking the system is free of plumbing problems, allowing sufficient time 

for all air to be purged, advance the thermostat setting to full on.

8.  The test device should now indicate heating. Turning the thermostat control 

through its full range should switch test indicators on and off.

9.  Leave the thermostat setting at the fully clockwise position so the test indicator  

is active and stop the pump. The indicator should switch off almost immediately. 

  If it fails to switch off restart pump quickly and adjust the screw on the pressure  

switch clockwise until heating stops. Adjust back until heating restarts and then 

  one further full turn. 

Stop/start pump several times until you are happy that 

the heating is switching on and off consistent with the pump running.

  REFER FIG 1.

N.B. If the heater is fitted to a portable pool or the equipment is 

mounted at about the same level as the pool water the pressure 

switch will probably not require adjustment. CHECK IT ANYWAY. 

It the equipment is mounted nelow the level of the pool water 

the static water pressure could be enough to hold the heating 

on after the pump stops. It is important for safety that this 

condition does not occur. FAILURE TO SET THE PRESSURE 

SWITCH CORRECTLY WILL VOID THE WARRANTY.

Содержание SpaPOWER Classic Heater

Страница 1: ...ntroller Please pass these instructions on to the operator of this equipment Note The pump is not intended for use by young children or infirm persons without supervision Please ensure that young chil...

Страница 2: ...s must comply with AS3000 and the special requirements of section 6 and any additional requirements of your local supply authority bylaws 6 In order to avoid the possibility of hypothermia heat stress...

Страница 3: ...her direction The head of the heater may be turned to any of the four keyed directions 90 to give best access to the thermostat control 3 When connecting pipework to heater make sure the O rings are p...

Страница 4: ...ting Turning the thermostat control through its full range should switch test indicators on and off 9 Leave the thermostat setting at the fully clockwise position so the test indicator is active and s...

Страница 5: ...ntrol head against the retaining edge before fitting to heater body Do not rely on locking ring to pull head and body together Use downward pressure while tightening locking ring making sure that loca...

Страница 6: ...6 NOTES...

Страница 7: ...place of purchase is at your cost and is your responsibility The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a rel...

Страница 8: ...ce 6 Lakeview Drive Scoresby Australia 3179 Ph 1300 232 839 Fax 1300 369 119 Email sales davey com au daveywater com NEW ZEALAND 7 Rockridge Avenue Penrose Auckland 1061 Ph 0800 654 333 Fax 0800 654 3...

Отзывы: