background image

2

INSTALLATIONS INSTRUCTIONS — PLEASE READ CAREFULLY

GENERAL

The spa heater is the first of a new generation of heaters that have been totally

redesigned to incorporate all the latest concepts in safe water heating. The heater 

is reliable, easy to install, simple to operate and easy to maintain. It includes all its 

own control and safety devices. It is designed to look after itself.
All the control system of the spa pack has to do is turn on the pump. The heater 

detects the water pressure change and operates accordingly.

INSTALLATION

Before planning any installation please note the following:
1. This equipment must be wired by a qualified electrician.
2. The heater power supply is not controlled by the spa control box.
3. Heaters up to 2.4kW are normally used for portable spa pools and thus the 

heater is provided with a 3 pin socket to permit the connection of a suitable 

control box directly to the heater without additional wiring.

4. This equipment must be supplied through a residual current device (RCD) – 

having a residual operating current not exceeding 30mA.

5. All installations must comply with AS3000 and the special requirements of 

section 6 and any additional requirements of your local supply authority bylaws.

6. In order to avoid the possibility of hypothermia (heat stress) occuring,  

it’s recommended that the average temperature of water not exceed 40°C.

7. The temperature rating of supply cord connected to the equipment shall not be 

less than 95°C.

PHYSICAL LOCATION

The heater should be located in the spa system as follows:
1.  On the pressure side of the pump.
2.  Before the filter in the return line.
3.  Where it is accessible for maintenance with enough clear room to remove 

control head from heater body.

4.  In a vertical position, or if horizontal, so that the side port faces down.
5. It is recommended that the Classic Spa Heater water inlet is set to the higher 

port. If for installation reasons this is not possible, the lower port can be used for 

water inlet as the Classic Spa Heater inlet / outlet ports can be interchanged.

6.  Level — definitely not plumbed at an angle.
7.  Protected from rain, water splashes, hosing etc.
8.  In an ambient temperature not exceeding 45°C.

Where the heater is being installed in a position exposed to the weather, 

splashing and the like, it must be protected by an additional enclosure 

having a degree of protection to IP24-AS1939.

Содержание SpaPOWER Classic Heater

Страница 1: ...ntroller Please pass these instructions on to the operator of this equipment Note The pump is not intended for use by young children or infirm persons without supervision Please ensure that young chil...

Страница 2: ...s must comply with AS3000 and the special requirements of section 6 and any additional requirements of your local supply authority bylaws 6 In order to avoid the possibility of hypothermia heat stress...

Страница 3: ...her direction The head of the heater may be turned to any of the four keyed directions 90 to give best access to the thermostat control 3 When connecting pipework to heater make sure the O rings are p...

Страница 4: ...ting Turning the thermostat control through its full range should switch test indicators on and off 9 Leave the thermostat setting at the fully clockwise position so the test indicator is active and s...

Страница 5: ...ntrol head against the retaining edge before fitting to heater body Do not rely on locking ring to pull head and body together Use downward pressure while tightening locking ring making sure that loca...

Страница 6: ...6 NOTES...

Страница 7: ...place of purchase is at your cost and is your responsibility The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a rel...

Страница 8: ...ce 6 Lakeview Drive Scoresby Australia 3179 Ph 1300 232 839 Fax 1300 369 119 Email sales davey com au daveywater com NEW ZEALAND 7 Rockridge Avenue Penrose Auckland 1061 Ph 0800 654 333 Fax 0800 654 3...

Отзывы: