13
English
Backwash
Can be set as a single speed or alternatively set two speeds and the pump speed will “pulse” between the
two settings. Minimum speed can be set between 1-10, maximum speed can only be set between 5-10.
External time present
Swipe this on or off, depending on whether you are using an external timer/chlorinator.
Disconnect function
The “disconnect from pump” function can be used to:
• Allow another device to control the pump;
• Disconnect so that you will not automatically connect to the pump;
• Please note that the Bluetooth connection will automatically disconnect after a minute of no communication.
Factory reset
This will reset the pump back to factory configurations and allows you to start the setup process again.
• Select “reset pump”;
• Turn dial to “off” position, then turn dial to “Bluetooth”;
• You can then re-pair with your phone. This procedure is in place so that the pump cannot accidentally be reset.
Pump fault finding
In the instance that there is a fault, the following screen will appear, with text description below the fault
indicating how to remedy.
SilensorPro BT
Fault title
Fault description
Pump fault – overcurrent
Check that the motor can rotate freely. Unplug for 1
minute and plug back in to reset. If problem persists call
Davey, or an authorised repair agent.
Pump fault – under voltage
Supply voltage issue. When power is back to normal,
unplug for 1 minute and plug back in to reset.
Pump fault – over temperature
Pump is too hot. Check the ambient temperature. Set to
lowest speed possible if ambient temperature is too high.
Pump fault – motor stalled
Check that the motor can rotate freely. Unplug for 1
minute and plug back in to reset.
Pump fault – underload/loss of prime
Check if there’s enough water inside the pump. Unplug for
1 minute and plug back in to reset. If problem persists call