The ProMaster

TM

 VSD Eco-Series has infinite speed settings from 1500 

to 3600RPM, so you can circulate your pool or spa water at any speed 
in between if required. Speeds can be adjusted to power a Suction pool 
cleaner, In-Floor cleaning system & Pool Heaters. A Backwash setting on 
the pump can be selected to backwash a media filter.

What to expect with VSD Eco speed pumping (energy efficient operation) 
on your pool:

If your ProMaster

TM

 pump is replacing a traditional AC motor pump, you will 

need to run it longer than your old fixed speed pump. This is NORMAL and 
you will save energy when using lower speed settings.

You may also notice that the pressure gauge on your filter is indicating 
a much lower pressure than you are used to. This is also NORMAL. The 
lower system pressure is simply a result of the lower speed and flow rate 
produced by the pump.

While running at the lower speed settings you will also notice a significant 
reduction in pump noise. This is a major benefit for you as it allows you to 
run your pump during off peak electricity tariffs, which will also assist in the 
reduction of your operating costs. Plus you will also have much happier 
neighbours.

Important Considerations when running the pump on Low Flow settings:

 

Many pool products rely on particular minimum flow rates for best operation 
and/or efficiency. If you are using the low flow setting on the ProMaster pump 
(e.g.: speed 1 to 4) Davey recommends that you check the compatibility of 
the speed or minimum flow rate required to run pool equipment such as:

•  Suction pool cleaners
•  Ozone generators
•  Pool Heaters
•  Solar Heating systems
•  Salt Water Chlorinator cells
•  In-floor pool cleaning systems

Содержание PM200SV

Страница 1: ...es may cause serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgable in swimming pool plumbing requirements following the installat...

Страница 2: ...ly water tested against a number of flow pressure voltage current and mechanical performance parameters Davey s advanced pump manufacturing technology provides reliable and efficient pumping performan...

Страница 3: ...his is also NORMAL The lower system pressure is simply a result of the lower speed and flow rate produced by the pump While running at the lower speed settings you will also notice a significant reduc...

Страница 4: ...Motor Input Power W hp Speed Setting 1 116W 0 16 hp Speed Setting 5 488W 0 65 hp Speed Setting 10 1000W 1 34 hp Backwash Setting 1316W 1 76 hp Operating Limits Max Water temperature 40 C Max Ambient...

Страница 5: ...240 volt 50 60Hz power supply and are equipped with a flex and 3 pin plug If a power outlet is not available within 3 metres of the pump a 3 pin power point in a safe dry place may need to be provided...

Страница 6: ...ivalent If the pump and filter are located below pool water level it is necessary to fit isolating valves in the pipe between the pump and skimmer box and in return pipe from the filter to the pool Th...

Страница 7: ...ould be connected to the inlet connection on the swimming pool filter usually at the filter control valve Barrel unions need to be hand tightened No sealant glues or silicones are required Prior to us...

Страница 8: ...elines for Recommended Pump Operating Hours Australian Standards AS3633 Private swimming pools water quality states that The minimum turnover rate shall be a single turnover of the full volume of the...

Страница 9: ...your pool and refer to the pressure indicated by the gauge on the media or cartridge filter Ensure flow rate is sufficient to cover your chlorinator cell plates completely at all times of operation 0...

Страница 10: ...o 10 A Davey Frill NeckWIZARD suction pool cleaner is recommended to run between speeds 3 to 6 4 The cleaner should only be connected for as long as is required to clean the surface of your pool When...

Страница 11: ...ge rubber o ring Firm hand tightness only is required The o ring thread can be lubricated with Hydra slip or equivalent products Failure to undertake regular maintenance may cause damage not covered b...

Страница 12: ...ox for blockage If the pump does not operate the following conditions may apply 1 The power is not connected For 240 volt only check the power point by plugging in a portable appliance to ensure power...

Страница 13: ...the o rings 4 Move the pipework with the barrel unions attached until the pump can be pulled clear NOTE When making any enquiries about your ProMasterTM be certain to quote the model number from the...

Страница 14: ...mer baskets and the pump hair and lint pots are free of leaves and debris at least once a week f Remove obstructions and combustibles from around the pump motor g Make sure all wiring connections are...

Страница 15: ...he Davey Guarantee Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever arising directly or indirectly from Davey pro...

Страница 16: ...ope 2 Rue A Fresnel 69680 Chaissie France Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 Email export davey com au Website daveyeurope eu DAVEY INTERNATIONAL Australian Head Office Ph 613 9730 9124 Fax...

Отзывы: