5.2 Settings
Functions
Factory Settings
Unit of measure
pH
Set point
7.4
Type of regulation
Acid- reduce the pH by dosage of an acid (pH-)
pH 7 calibration
To an accuracy more than 0.2 pH
Proportional regulation*
Factory function
* Proportional: Dosage adjusted according to different cycles time/breaks. At the approach
of the set point, the pump reduces its time of dosing.
5.2.1 Adjustment of the Set Point
The calibration of AS Series is completed;
It is now ready to measure the pH of your pool.
3) Next immerse
the probe in the
pH 7 solution, stir
around in bottle
and leave it in the
solution being
careful not to
touch the probe
or the cable.
4) After a period of at least one minute,
the stabilized value is displayed. Press the
CAL button until the display shows CAL
flashing then release. The quality of the
probe reading is then briefly displayed.
When you press the SET button,
the value of the set point is
displayed.
To change the value of the set
point, press SET and press CAL
by pulse. Each pulse changes
the pH value by 0.1 pH,
between 7.0 and 7.6.