• Do not leave the equipment exposed to atmospheric agents

• Do not allow the pump to be used by children or unskilled individuals 

without supervision

• In case of breakdown or improper functioning of the pump, switch it 

off, but do not touch. Contact Davey for technical assistance for any 

necessary repairs and insist on the use of original spares. Failure to 

respect this condition could render the pump unsafe to use

• When the Davey pH Pump is not in use for a substantial period of time, 

or use is to be discontinued, disconnect the unit from any power supply

  Before carrying out any service on the pump:
1) Disconnect the mains power from the unit and
2) Relieve all the pressure from the pump head or the injection tube
In the event of possible losses on the hydraulic system of the pump 

(breakage of the O-ring, the valves or the hoses), stop the pump 

immediately and contact Davey.

1.3 Toxic and/or Dangerous Liquid Dosage

To avoid risk from contact with hazardous liquids or toxic fumes, always 

adhere to the notes in this instruction manual and wear protective clothing 

(gloves, goggles & overalls).

• Follow the instructions of the dosing liquid manufacturer
• Check the tubing regularly and use only if there is no damage
• Contact Davey for technical assistance for any necessary repairs and 

insist on the use of original spares

• Before disconnecting the metering pump, make sure to flush out and 

neutralise the pump head with water

1.4 Instructions for diluting pool acid

The ChloroMatic

®

 Salt Water Chlorinator with pH control, automatically 

doses a diluted acid solution into the pool when the pH level needs to be 

reduced. The peristaltic pump draws this diluted acid from a container in 

which the solution is mixed.
Use the table below to determine what water/acid ratio is recommended for 

your pool, in an approved 20 litre Hydrochloric Acid container. 

IMPORTANT: KEEP BARE HANDS AWAY FROM POOL ACID AND ALWAYS 

USE CAUTION WHEN HANDLING POOL CHEMICALS.

Содержание M5138

Страница 1: ...age The installation of this product should be carried out by a person knowledgable in swimming pool plumbing requirements following the installation instructions provided in this manual Please pass t...

Страница 2: ...description of Tube on the Injection Valve 10 4 Connecting the power and pool pump to your pH 11 5 Commissioning and Operation 12 5 1 Calibration Procedure 12 5 2 Settings 13 5 2 1 Adjustment of the S...

Страница 3: ...dangerous The pump should not therefore be used for applications that were not allowed for in its design In case of doubt please refer to the details listed within this document or contact your point...

Страница 4: ...Davey 1 3 Toxic and or Dangerous Liquid Dosage To avoid risk from contact with hazardous liquids or toxic fumes always adhere to the notes in this instruction manual and wear protective clothing glov...

Страница 5: ...pump B 4 meters of PVC Cristal tube C Screws for wall mounting D Masonry plugs for wall mounting E Electrode pH Probe Protective Cap F Clamp DN40 x 2 G Clamp DN50 x 2 H Foot filter I Injection valve J...

Страница 6: ...ress CAL allows calibration of the pH to pH 7 0 when using the buffer solution pH7 3 Current value of pH being measured eg 7 0 4 pH unit of measurement and indicates that the device must inject acid 5...

Страница 7: ...iltration pump is running WARNING It is important to keep a minimum distance of 200mm between the injection valve E and the probe C The injection valve E must be placed last in the pipework hydraulic...

Страница 8: ...1 Bracket 1 Locate the bracket in the space chosen and mark the holes 2 Drill the holes as required 3mm for timber walls 6mm for masonry walls 3 Fix the bracket to the wall 4 Slide and secure pump int...

Страница 9: ...e pH pump controller Fig 8 Probe nut Disk brake Washer seat O ring Bracket 3 2 3 Mounting of the pH Probe into the Probe Holder After removing the protective cap from the probe you need to ensure all...

Страница 10: ...tom of the conical nipple 3 Screw the nut by hand onto the nipple Fig 10 3 2 4 Mounting of Injection Valve Fig 9 Put Teflon tape on threads Choose a mounting location on your pipework that is 1 Prior...

Страница 11: ...so it operates during the preset filtration time cycles If your pool pump is plugged into your Chlorinator 1 Remove the pump plug from the Chlorinator pump power socket Usually at the bottom of the Ch...

Страница 12: ...for reuse at the time of winterising 2 Rinse the probe in tap water for at least 20 minutes Steps Before carrying out the calibration of the probe remember to Stop the filtration pump Close the isolat...

Страница 13: ...s completed It is now ready to measure the pH of your pool 3 Next immerse the probe in the pH 7 solution stir around in bottle and leave it in the solution being careful not to touch the probe or the...

Страница 14: ...s non operational time period proportional to the required dosage demand That is why the device often has the pump off This is normal Adjust the pH slowly to preserve the natural quality of your water...

Страница 15: ...l deposit on the sensing element of the probe To overcome this problem it is advisable to use the cleaning solution for electrode pH probe and redox AYACSOLNET01 and follow the procedure on the suppli...

Страница 16: ...r 1 Change the probe 2 Change the buffer solution 3 Change over the probe Alarm Alr Err If the pH is lower than pH 5 or above pH 9 this alarm will be displayed and dosing will be stopped Adjust your w...

Страница 17: ...assy Pre April 18 only 1 2 Roller assy Post Mar 18 only B 1 3 402802 Squeeze tube assy inc clips Pre April 18 only 1 3 Squeeze tube assy inc clips Post Mar 18 only B 1 5 403464 Kit roller assy probe...

Страница 18: ...ity The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if o a relevant defect is found o the warranty claim is made duri...

Страница 19: ......

Страница 20: ...eview Drive Scoresby Australia 3179 Ph 1300 232 839 Fax 1300 369 119 Email sales davey com au daveywater com NEW ZEALAND 7 Rockridge Avenue Penrose Auckland 1061 Ph 0800 654 333 Fax 0800 654 334 Email...

Отзывы: