IP55 Compliant Connection

For some installations, such as wet areas in dairies, the pump is required to be 

IPX5 compliant.  The Dynaflo HS pump is IP55 compliant.

Pipe Connections

For best performance use P.V.C. or 

polythene pipe at least the same 

diameter as the pump’s inlet.  Larger 

diameter pipe may be used to minimise 

resistance to flow when pumping longer 

distances.

Use unions at pipe connections to enable easy 

removal and servicing. Use sufficient tape to 

ensure airtight seal and hand tighten only, do 

not screw connections all the way into suction 

port. To prevent strain on pump thread always 

support heavy inlet and outlet pipes. 

Lay suction pipe at a constant gradient to avoid 

air pockets which may reduce pump efficiency.

Connection to your Water Source

ABOVE GROUND WATER SOURCES

Installations with flooded suction require a gate valve so water supply can be 

turned off for pump removal and servicing.

Leave the in-built one-way check 

valve installed to avoid water draining 

back past the pump while not in 

operation and causing possible pump 

damage.

Connection to your Water Source

BELOW GROUND WATER SOURCES

Prior to using this pump you must ensure that:

•  The pump is installed in a safe and dry environment

•  The pump enclosure has adequate drainage in the event of leakage

•  Any transport plugs are removed

•  The pipe-work is correctly sealed and supported

•  The pump is primed correctly

•  The power supply is correctly connected

•  All steps have been taken for safe operation

Appropriate details for all of these items are contained in the following Installation and 

Operating Instructions.  Read these in their entirety before switching on this pump.  If you 

are uncertain as to any of these Installation and Operating Instructions please contact 

your Davey dealer or the appropriate Davey office as listed on the back of this document.

Choosing a Site

Choose a site with a firm base as close to the water 

source as possible with correct power supply. Make 

sure your pump is always connected to an adequate, 

reliable source of clean water.

Housing your Davey Pump

To protect your pump from the weather, make 

sure the pump house is both water proof, frost 

free and has adequate ventilation.

The pump should be mounted on a firm base 

allowing for drainage, to avoid damage to 

flooring etc., that over time may occur from 

leaking pipe joints or pump seals.

Do not mount the pump vertically.

Power Connection

In accordance with AS/NZS 60335.2.41 we are obliged to inform you that this 

pump is not to be used by children or infirm persons and must not be used as a 

toy by children.

Whenever the installation position of the pump is higher than the lowest water 

level, a foot valve fitted to the end of the suction pipe as illustrated in (A) below 

is required.  Ensure that the foot valve is at least 

1

/

2

 metre below minimum 

water level.

SPEAR POINT INSTALLATIONS

When a Dynaflo HS is installed on a spear or well point, the in-built check valve 

MUST

 be removed and a check valve fitted immediately on top of the spear 

point itself, as shown in (B) above.

Removal of in-built check valve

 

(where fitted)

If your installation requires the removal of the in-built check valve or the in-

built check valve requires removal for servicing, this can be achieved without 

difficulty.

The in-built check valve is a cassette design, which is screwed in through the 

suction inlet.

Removal of the check valve cassette is achieved by inserting any suitable tool 

(eg: a pair of pliers or the handle from an adjusting spanner) into the inlet.  

The check valve cassette has various ribs and recesses to allow a variety of 

nonspecific tools to be used in the removal or insertion process.

Spear Size 

Mesh 

Approx. Max. Capacity of Spear Point

1

1

/

4

”  (32mm) 

  60 

15 - 23 l/min  or  200 -   300 gal/hr

1

1

/

2

”  (38mm) 

  60 

23 - 38 l/min  or  300 -   500 gal/hr

2” 

(50mm) 

  60 

38 - 75 l/min  or  500 - 1000 gal/hr

Before installing your new pump, please read all instructions carefully as failures 

caused by incorrect installation or operation are not covered by the guarantee. 

Your  Dynaflo  HS  Electric  Pump  is  designed  to  handle  clean  water.  The  pump 

should  not  be  used  for  any  other  purpose  without  specific  referral  to  Davey. 

The  use  of  the  pump  to  pump  flammable,  corrosive  and  other  materials  of  a 

hazardous nature is specifically excluded.

Connect lead to power supply designated on pump label, do not 

use long extension leads as they cause substantial voltage drop, 

poor pump performance and may cause motor overload.

The electrical connections and checks must be made by a 

qualified electrician and comply with applicable local standards.

DO NOT USE THREAD SEALING COMPOUNDS, HEMP OR PIPE 

DOPE!

NOTE: Suction leaks are the largest 

cause of poor pump performance 

and are difficult to detect. Ensure 

all connections are completely 

sealed using thread tape only.

DO NOT USE SEALING COM-

POUNDS OR PIPE DOPE. 

NOTE:  DO NOT install the check valve at the pump or at the top of 

the well.  DO NOT run the pump without water.

NOTE:  Be certain to select the spear point to suit the well conditions 

and regulate the flow rate from the pump accordingly.

NOTE: Prior to installation remove the red transport plugs & associated seals from 

the suction and/or discharge ports.

NOTE:  HS models are fitted with an in-built suction check valve 

which should be removed on all suction lift applications and a 

foot valve or check valve installed in the suction pipework as 

appropriate.