background image

 7

TROUBLE SHOOTING

1.

Pump not delivering water or not building up pressure

May be caused by one or more of the following :
a.

Pump not properly primed

b.

Foot valve leaking on suction lift

c.

Suction lift too high

d.

Suction piping not correctly sealed or holed allowing air to enter pump suction

e.

Blocked or worn impellers

f.

Insufficient water supply source

g.

Reverse rotation

2.

Motor not running

May be caused by one or more of the following :
a.

Power failure

b.

Blown fuse

c.

Motor overload tripped

d.

Motor windings faulty

3.

Motor thermal overload tripping

May be caused by one or more of the following :
a.

Low voltage supply

b.

Motor or pump seized

c.

Motor windings faulty

d.

Frequent cycling

To check for correct automatic pressure system operation:

Close gate valve at pump outlet, allowing pump to run and build up pressure until it
switches off at cut-out setting of pressure switch or Hydrascan

®

.

Open gate valve at pump outlet to allow water to discharge to an outlet point.
Pump will automatically switch on at cut-in setting of pressure switch or Hydrascan.

Содержание HS Series

Страница 1: ...ffice and Manufacturing 6 Lakeview Drive Scoresby Australia 3179 Ph 61397309222 Fax 61 3 9753 4100 Website www davey com au CustomerServiceCentre Ph 1300367866 Fax 1300369119 E mail sales davey com au...

Страница 2: ...tion the Davey pump motor is fitted with an automatic reset thermal overload constant tripping of this overload indicates a problem e g low voltage at pump excessive temperature above 50 C in pump enc...

Страница 3: ...r and put the mechanical seal on using a little water on the rubber boot and pushing it down over the shaft until the seal faces meet The carbon seal face should be in contact with the ceramic wear fa...

Страница 4: ...d wear ring One more stage body and another impeller in the case of a four stage pump or a spacer in place of the impel ler if it is a three stage pump The impeller spacer or the impeller should be si...

Страница 5: ...g and screw the non return valve cartridge into the suction port in a clockwise rotation using non specified tools eg a screwdriver handle a pair of pliers a large coin or a flat blade 20mm wide 14 Yo...

Страница 6: ...You will now see a stainless steel nut that holds the rest of the pump assembly in place This is removed with a 17mm ring spanner You will need to sit the pump horizontally and remove the fan cowl Pl...

Страница 7: ...the following a Power failure b Blown fuse c Motor overload tripped d Motor windings faulty 3 Motor thermal overload tripping May be caused by one or more of the following a Low voltage supply b Motor...

Страница 8: ...oilet cistern hot water system or stock troughs allowing unit to overflow d Pressure tank not retaining air pressure or air change too high pressure switch model only 6 Pump not switching off or takin...

Отзывы: