PLACING FILTER INTO SERVICE

1  Before placing filter into service, media must be soaked for at least two 

hours; 24 hours for carbon filter.

2  Once media is soaked, push the recycling button

 

 

for five seconds to 

start backwash.

3  You can shorten the backwash time by pushing both 

 and 

 buttons.

4  A few short cycle backwashes are better than a full long one as dust and 

dirt will release with change of flow direction. Carbon filter requires five to 
seven backwash cycles until backwash water is clear.

MEDIA PLACEMENT

Multi-media sediment filter

Sequence 

in tank

EAFM7

Code

EAFM9

Code

EAFM12

Code

1st

5kg
No.6 gravel

EM10A 9kg D1

EM24

22kg D1

EM24

2nd

10kg
7m sand

EM17

5kg D2

EM14

10kg D2

EM14

3rd

4kg
Filter coal

EM18

9kg 7m

EM17

22kg 7m

EM17

4th

7kg
Filter coal

EM18

18kg
Filter coal

EM18

Carbon Taste & Odour Filter

Sequence 

in tank

EAFC7

EAFC9

EAFC12

Code

1st

5kg No.6 gravel

5kg No.6 gravel

10kg No.6 gravel EM10A

2nd

4kg 1240 carbon 7kg 1240 carbon 17kg 1240 carbon EM11A

Neutralising Filter

Sequence 

in tank

EAFN7

EAFN9

EAFN12

Code

1st

5kg No.6 gravel

5kg No.6 gravel

10kg No.6 gravel EM10A

2nd

14kg Neutrafil

25kg Neutrafil

60kg Neutrafil

EM23 / 
EM23C

Содержание EAFM7

Страница 1: ...EAFM EAFC EAFN Filters Installation and Operating Instructions Please pass these instructions on to the operator of this equipment...

Страница 2: ...s to avoid hot water backup to the filter The filter must be protected against freezing water temperatures Backwash this unit at least weekly to prevent media compaction and channeling As the valve is...

Страница 3: ...is sitting on the bottom of the tank then place the media in the tank as follows leveling media between each layer DO NOT shake filter to level the media 5 Remove plug or cover from the distributor t...

Страница 4: ...ds to be set 1 Connect the 240 12V adapter to the controller and switch on power 2 A default time is displayed 3 Press The default time will flash Use the and arrows to adjust to the current time 4 Pr...

Страница 5: ...ash water is clear MEDIA PLACEMENT Multi media sediment filter Sequence in tank EAFM7 Code EAFM9 Code EAFM12 Code 1st 5kg No 6 gravel EM10A 9kg D1 EM24 22kg D1 EM24 2nd 10kg 7m sand EM17 5kg D2 EM14 1...

Страница 6: ...ace a cap over the riser pipe 4 Add Neutrafil to the tank so it is approx 2 3 full 5 Ensure there is no media in the tank thread Remove the cap on the riser pipe 6a If the riser pipe has lifted when r...

Страница 7: ...any other costs incurred in making a claim Please retain your receipt as proof of purchase you MUST provide evidence of the date of original purchase when claiming under the Davey One Year Guarantee...

Страница 8: ...N 18 066 327 517 NEW ZEALAND Customer Service Centre 7 Rockridge Avenue Penrose Auckland 1061 Ph 0800 654 333 Fax 0800 654 334 Website daveynz co nz Email sales dwp co nz Davey is a registered tradema...

Отзывы: