5
PLACING FILTER INTO SERVICE
1 Before placing filter into service, media must be soaked for at least two
hours; 24 hours for carbon filter.
2 Once media is soaked, push the recycling button
for five seconds to
start backwash.
3 You can shorten the backwash time by pushing both
■
and
buttons.
4 A few short cycle backwashes are better than a full long one as dust and
dirt will release with change of flow direction. Carbon filter requires five to
seven backwash cycles until backwash water is clear.
MEDIA PLACEMENT
Multi-media sediment filter
Sequence
in tank
EAFM7
Code
EAFM9
Code
EAFM12
Code
1st
5kg
No.6 gravel
EM10A 9kg D1
EM24
22kg D1
EM24
2nd
10kg
7m sand
EM17
5kg D2
EM14
10kg D2
EM14
3rd
4kg
Filter coal
EM18
9kg 7m
EM17
22kg 7m
EM17
4th
–
–
7kg
Filter coal
EM18
18kg
Filter coal
EM18
Carbon Taste & Odour Filter
Sequence
in tank
EAFC7
EAFC9
EAFC12
Code
1st
5kg No.6 gravel
5kg No.6 gravel
10kg No.6 gravel EM10A
2nd
4kg 1240 carbon 7kg 1240 carbon 17kg 1240 carbon EM11A
Neutralising Filter
Sequence
in tank
EAFN7
EAFN9
EAFN12
Code
1st
5kg No.6 gravel
5kg No.6 gravel
10kg No.6 gravel EM10A
2nd
14kg Neutrafil
25kg Neutrafil
60kg Neutrafil
EM23 /
EM23C