Figure 7.6
The connection between the DynaDrive controllers requires 2 x 0.25mm2 cable. From one DynaDrive,
use the “COMUNIC” terminal 2. Wire to the “COMUNIC” terminal 2 of the second DynaDrive. To complete
the circuit, from one DynaDrive, use the “COMUNIC” terminal 3. Wire to the “COMUNIC” terminal 3 of the
second DynaDrive. Davey suggests limiting the distance between the pumps to 2m. To set up multiple
DynaDrive to run in a common manifolded system use the following:
• The primary pump is indicated by a solid green
Automatic LED
(even in standby);
• When secondary pump is unneeded, the
Automatic LED
is flashing green;
• When water is in demand, the first pump to start is the last pump to return to standby;
In a daisy-chain installation, pumps that are running can be identified by an amber
Prime LED
, see
figure 7.7. If the pump is in standby, the
Prime LED
is off;