background image

10

•  Using the  

 

Menu up button

 or 

 

Menu down button

 we can change the values on display. 

•  Press  

 

Enter button

, for validation.

•  Whenever you want to quit the configuration sequence, press 

 

Menu button

.

•  After every  

 

Enter button

, DynaDrive will switch to the next menu in the configuration sequence.

5.3 VSD features

•  Auto reset after dry run detected;
•  Auto reset after loss of power;
•  Option for adapting (volt-free) tank level sensor into programming;
•  Control and information panel with LCD screen;
•  Includes pressure transducer;
•  Under current visual alarm;
•  Over current protection by way of shut down and visual alarm;
•  Data logging of operation controls and alarms including run duration;
•  Aluminum heat exchanger;
•  VSD cooling by pump’s fan, lowering cooling costs by way of additional fans;
•  Motor and VSD protection from onsite “brown-outs” by way of shut down, visual alarm & auto re-try after 

correct voltage regained;

•  Protection from motor locked rotor by way of auto shut down;
•  Adaptable for daisy-chain multiple pumps in parallel, up to 2 pumps;
•  Fault diagnosing software for user troubleshooting;
•  Adjustable pressure set points via easy to use touchpad in 10kPa (1½psi) increments;; and
•  3-minute manual override for priming.

6. OPERATION

6.1 Start-up procedure

After power is initially turned on to the DynaDrive, the display shows the software version and the name 

Davey, see figure 6.1. All LEDs flash for the initial ~ 5 seconds. The  

 

Power LED

 will remain lit green, 

showing the DynaDrive has power.

Figure 6.1 

P/

N

:1

61

15

-1 B

DAVEY

VER. 0 1

Содержание DynaDrive DD15-35NPT

Страница 1: ...to www bit ly dynadrive for any product information updates or simply scan this QR code These can also be found on the product nameplate Please pass these instructions on to the operator of this equip...

Страница 2: ...6 4 3 Air Handling 6 4 4 Power connection 7 4 5 The pressure tank 8 5 FEATURES 9 5 1 System features 9 5 2 DynaDrive display layout 9 5 3 VSD features 10 6 OPERATION 10 6 1 Start up procedure 10 6 2 M...

Страница 3: ...from aged 8 years and above and persons with reduced physical sensory mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the a...

Страница 4: ...essures Davey Water Product Pty Ltd cannot accept responsibility for loss or damage resulting from incorrect installations A pressure reducing valve is required on the suction side of the pump when th...

Страница 5: ...tart stop In such as case it is worth considering upsizing the pressure tank to help absorb these pressure fluctuations If concerned please consult your Davey representative 3 4 Spear point installati...

Страница 6: ...ance to flow when pumping for distances longer than 5m 16 Use unions at pipe connections to enable easy removal and servicing Use enough plumbers tape to ensure airtight seal and hand tighten only do...

Страница 7: ...blems ATTENTION Ensure that any and all electrical work is only undertaken by an authorized electrician Before obtaining access to terminals all supply circuits must be disconnected The electrical con...

Страница 8: ...edures Remove the pressure tank completely from pump installation ensuring to isolate the pressure tank and release the water pressure from the tank beforehand or Release all water pressure from the p...

Страница 9: ...ducing the inconvenience of pressure variation in showers etc Allows for independent switch to override DynaDrive operation This could be particularly handy if using a float switch in a source tank Al...

Страница 10: ...g run duration Aluminum heat exchanger VSD cooling by pump s fan lowering cooling costs by way of additional fans Motor and VSD protection from onsite brown outs by way of shut down visual alarm auto...

Страница 11: ...on the bottom line shown in Figure 6 2 The default unit of measurement is psi Figure 6 2 P N 16115 1 B P N 16115 1 B Pset 60 Pact 0 To start the DynaDrive Pushing the Automatic on manual off button to...

Страница 12: ...aintaining pressure see figure 6 4 Figure 6 4 P N 16115 1 B P N 16115 1 B Pset 60 Pact 60 6 2 Manual override In addition to automated control DynaDrive can also be run in manual override on should th...

Страница 13: ...and hold the Prime button The pump will turn on and continue to run until the Prime button is released see figure 6 6 While the pump is in manual override the Prime LED will illuminate orange see fig...

Страница 14: ...ow the pressure set but changes from showing actual pressure to the frequency of power supplying the motor see figure 6 7 This dictates the speed that the motor runs Figure 6 7 P N 16115 1 B P N 16115...

Страница 15: ...ssure tank of the installation chapter The set pressure cannot be changed while the pump is running or in automatic mode To change the set pressure Ensure automated control is turned off To turn the a...

Страница 16: ...t back to normal display To change the set pressure use the Menu up button or Menu down button Pressure changes are in multiples 5psi Once you ve reached your new set point see figure 6 11 Figure 6 11...

Страница 17: ...7 4 and install a larger pressure tank If you have any further concerns please contact your local Davey representative 6 6 Decommissioning the DynaDrive Should it become necessary to decommission the...

Страница 18: ...he automated control off push the Automatic on manual off button The green Automatic LED will turn off see figure 7 1 Figure 7 1 P N 16115 1 B P N 16115 1 B Pset 60 Pact 60 Once the motor has slowed t...

Страница 19: ...daisy chain installation the cut in of the secondary pump occurs after the same pressure drop as the primary pump is set 7 2 Changing the min frequency The default minimum frequency of DynaDrive is 15...

Страница 20: ...normal display Using the Menu up button and Menu down button scroll through to Min Freq Use the Menu up button and Menu down button to change the setting to The setting will change by 5Hz Press the En...

Страница 21: ...a float switch on a source tank eg rainwater tank To wire in an independent switch refer figure 7 5 and 7 6 Figure 7 5 Power supply Pressure transmitter Pump connection single phase pumps O Lead Lag...

Страница 22: ...anual off button The green Automatic LED will turn off see figure 7 7 Figure 7 7 P N 16115 1 B P N 16115 1 B Pset 60 Pact 60 Once the motor has slowed to a stop press and hold the Menu button and Ente...

Страница 23: ...al float can be wired into the DynaDrive controller The normally open terminals will not trigger fault alarm pause conditions When the terminals are closed circuit the DynaDrive operates normally Dave...

Страница 24: ...naDrive will come on if the first pump is unable to maintain set pressure even when running at 100 speed The next time water is in demand the LAG pump will come on first This sequence is referred to a...

Страница 25: ...wer was still available to the unit The normally closed configuration is allowing the monitoring system to sense if unit were inoperable due to alarm or loss of power The Optional Remote Alarm module...

Страница 26: ...15 0 16 0 17 kW P2 per stage kW P 2 FLOW psi 0 TOTAL HEAD ft 0 20 40 60 80 100 120 140 160 180 10 20 30 40 50 60 70 FLOW US gpm 0 4 8 12 16 20 24 0 4 8 12 16 20 24 US gpm 4 8 12 16 20 24 Qgpm 0 40 60...

Страница 27: ...Impellers 304 stainless steel Stages casing 304 stainless steel Pump shaft 316 stainless steel Stage centring device 304 stainless steel Mechanical seal rotating Carbon Mechanical seal stationary Cera...

Страница 28: ...anks life Safely disconnect the tank from the water supply discharge all air from the tank and flush the tank several times with clean water Once the flushing water is clean reconnect the tank and rec...

Страница 29: ...roblem persists contact your Davey representative via the details at the end of this manual Fault light flashes on DynaDrive display A9 UNDER VOL shows on DynaDrive display DynaDrive attempts restart...

Страница 30: ...s required 13665 9 A Stage Body 2nd stage with valve assy 1 32912 10 Stage body Inner stages As required 13662 2 11 Stage body Final 1 13663 12 Spacer Destage 1 13696 1 13 B Washer Cup As required 136...

Страница 31: ...31...

Страница 32: ...thorized service agent Davey will not be liable for any cost of removal installation transport or any other charges that may arise in connection with the warranty claim Product eligible for repair or...

Отзывы: