3
NOTE: To avoid possible water damage to property from ruptured pipes,
leaking connections, worn/leaking pump seals, etc., pumps must be
installed on a well drained site or in a properly constructed drain tray.
Electrical Connection
In the interests of safety, we advise that all Spa Bath Pumps must be installed in
accordance with relevant standards, particularly AS 3000 wiring rules or equivalent.
IMPORTANT INFORMATION:
Your Davey pump is Double Insulated to
Water Circuit. If equipotential bonding structure is required, then a
Equipotential Bonding Point is provided. (Please refer to your local statutes
and regulations for AS/NZ 3000 Wiring standards).
This product is suitable for connection to a nominal 240V 50Hz power supply and is
equipped with a lead and three pin plug.
This product must be installed so the motor can be turned off independently of the air
button or touch pad (a standard ON/OFF power point provides this).
If the supply cord of this product is damaged it must be replaced with a genuine Davey
Spare Part, by the manufacturer or its service agent or a similar qualified person in order to
avoid a hazard.
Warning! Ensure that an electrical isolation switch is located with
easy access so that the pump can be switched off in an emergency.
Air Switch Models -
Tube Connection
These pumps are supplied with an air switch tube connected to the back of the motor on
the 200, 270 & 400.
1. Before installing, ensure that :
- the tube is properly connected to the pump,
- the tube can be connected to the air button (not supplied) at the bath.
2. When installing route the tube via the shortest possible path to the air button.
Ensure that there are no kinks.
3. Do not loop air tube around pipe work or framing.
Electronic Models -
Touchpad Assembly / Installation
These models are supplied with a low voltage electronic touch pad to control pump and
heater functions.
Assembly
Click faceplate onto touch pad. Then apply label to faceplate/touchpad assembly ensuring
it is right way up.
Installation
The assembled touchpad is then ready for mounting at the bath. Route the lead to enable
connection at both the touchpad and pump ends. A 26mm dia. hole is required to mount
the touchpad flush on the bath surface (usually pre drilled by bath manufacturer).
Apply a bead of silicone on the touchpad box only to secure it to the bath surface and prevent
water leaking under the bath. Do not silicone the clip on faceplate to the bath surface.